No Detail Found!

Determination of efficiency of the vertical specularly reflecting cylindrical light shaft for different types of firmaments

Author(s)
Serhii Litnitskyi Department of Architectural Design Fundamentals, Construction and Graphics, Institute of Civil Engineering and Architecture, National University of Water and Environmental Engineering,Rivne,Ukraine
Eugene Pugachov Department of Architectural Design Fundamentals, Construction and Graphics, Institute of Civil Engineering and Architecture, National University of Water and Environmental Engineering,Rivne,Ukraine
Taras Kundrat Department of Architectural Design Fundamentals, Construction and Graphics, Institute of Civil Engineering and Architecture, National University of Water and Environmental Engineering,Rivne,Ukraine
Vasyl Zdanevych Department of Architectural Design Fundamentals, Construction and Graphics, Institute of Civil Engineering and Architecture, National University of Water and Environmental Engineering,Rivne,Ukraine
Abstract
Article is devoted to determination of efficiency of the vertical specularly reflecting cylindrical light shaft for various types of the firmaments standardized by CIE (International Commission on Illumination). Efficiency of the light shaft was calculated as the relation of the output luminous flux (exiting through the lower base of the shaft) to the entering luminous flux (entering through the upper base of the shaft). The output luminous flux consists of the luminous flux created by direct light (gets on base of the shaft directly from the sky) and the luminous flux created by light which is repeatedly reflected from its inner side surface. For the 4th and 15th types of firmaments surfaces of dependence of the total efficiency (formed by the direct and reflected light) of the light shaft from solar time and the index of the shaft and also - graphs of dependence of total efficiency of the light shaft on the index of the shaft are given. For the 4th types of firmament the maximum values correspond to solar noon (from 29.3% to 96.3%), and the minimum values are at sunrise and sunset (from 28.7% to 95.3%). For the 15th types of firmament the maximum values correspond to solar noon (from 15.5% to 95.8%), and the minimum values are at sunrise and sunset (from 13% to 91.5%). The results showed that the solar time has almost no effect on the efficiency of the light shaft, which allows us to average the results in a certain way. As the light shaft index increases, that is, as the ratio of the radius to the shaft height increases, the efficiency value asymptotically approaches one hundred percent, which is physically correct. Knowing the radius, height, index of the shaft and the specular reflection coefficient of its inner surface, it is possible to predict natural lighting under the shaft and use energy resources more rationally.
Publication Details
Page(s) 278-292
Published Journal: Journal of Daylighting, Volume: 12, Issue: 2, Year: 2025

Request the full text from PASTIC

Keywords
repeated luminous reflectance, natural illumination, light shaft, firmament
References
.1997 .«CIE standard overcast sky and clear sky».. , : .
. .ISO 15469: 2004(E). «Spatial distribution of daylight - CIE standard general sky».. , : .
.2016 .Spatial daylight brightness distribution. CIE standard cloudy and cloudless sky (ISO 15469:2004, IDT)». (in Ukrainian) K. Alshaibani, Average Daylight Factor for the ISO/CIE Standard General Sky, Lighting Res. Technol, 48 : 742-754.
Kittler R. .2002 .General Sky Standard Defining Luminance Distribution. Proceedings of eSim Conference, : 36-43.
Kittler R.,Darula S. .2014 .The Research Search for the Least Beneficial Overcast Sky and Progress in Defining Its Luminance Gradation Function. Building Research Journal, 61 : 151-166.
Li W.,Tang L.,Lee M.,Munner T. .2009 .Classification of CIE Standard Skies Using Probabilistic Neural Networks. International Journal of Climatology, 30 : 305-315.
Tregenza P. R.,Island Jeju .2015 .Analysing Sky Luminance Scans to Obtain Frequency Distributions of CIE Standard General Skies Generation Communication. FGCN 2015 IEEE CPS Post Proceedings. Jeju: SERSC, : 49-54.
Yu-Feng Ho .2012 .Thesis for the Degree of Master. , : .
D. H.W. Li T.C.,Chau T.C.,K. K.W. Wan T.C. .2014 .A Review of the CIE General Sky Classification Approaches, Renewable and Sustainable Energy Reviews. , 31 : 563-574.
Radomtsev D.,Sergeychuk O. .2016 .Implementation of CIE General Sky Model Approach in Ukraine and Effects on Room Illuminance Mode. International Journal of Smart Home. Tasmania: SERSC, 10 : 57-70.
Radomtsev D.,Sergeychuk O. .2007 ."CIE Standard General Sky" under. Designing Systems [14] [16] [18] [20] [21] [22] [23] [24] [25] [26] [27] [28] of Room Daylighting. 9th International Conference on Future Technology, 39 : 31-51.
Wittkopf S. K. .2004 .Analysing Sky Luminance Scans and Predicting Frequent Sky Patterns in Singapore, Lighting Research and. Lighting Research and Technology, 36 : 271-281.
M. B. Piderit C.,Cauwerts M.,Diaz M. .2014 .Definition of the CIE Standard Skies and Application of the HDRI Technique to Characterize the Spatial Distribution of Daylight in Chile. Journal of Construction, 13 : 22-30.
Ng E.,Mu J.,Lee M.,Gadi A. .2007 .Defining Standard Skies for Hong Kong. Building and Enviroment, 42 : 866-876.
Pugachev E. V.,Litnitskyi S. I.,Kundrat T. M.,Zdanevych V. A. .2023 .Definion Analysis of the Ratio of the Luminance in an Arbitrary Sky Elements to the Zenith Luminance Given in DSTU ISO 15469:2008, Modern Problems of Modeling 25 (. , : 184-192.
Kocifaj M.,Kundracik F.,Darula S.,Kittler R. .2010 .Theoretical Solution for Light Transmission of a Bended Hollow Light Guide. Solar Energy, 84 : 1422-1432.
Acosta I.,Navarro J.,Sendra J. J. .2014 .Lighting Design in Courtyards: Predictive Method of Daylight Factors under Overcast Sky Conditions. Renewable Energy, 71 : 243-254.
Kocifaj M.,Darula S.,Kittler R.,Hollow Light Guide Interior Illumination Method - An Analytic Calculation Approach for Cylindrical R. .2008 .. Solar Energy, 82 : 247-259.
Kittler R.,Kocifaj M.,Darula S.,Technology Daylighting .2012 .. , : .
Phillips D. .2004 .. , : .
T. M. Kundrat ,Ukrainian) M. Kocifaj F.,Kundracik S.,Darula R.,Kittler R. .2012 .Availability of Luminous Flux below a Bended Light-Pipe: Design Modelling under Optimal Daylight Conditions. Solar Energy, 86 : 2753-2761.
H. von Wachenfelt V.,Vakouli A. P.,Diéguez' N.,Gentile C.,Dubois and K.-H. Jeppsson C. .2015 .Lighting Energy Saving with Light Pipe in Farm Animal Production. Journal of Daylighting, 2 : 21-31.
Diéguez' A. P.,Gentile N.,M.-C. Dubois N. .2016 .Daylight Utilization with Light Pipe in Farm Animal Production: A Simulation Approach. Journal of Daylighting, 3 : 1-11.
Obradovic B.,Matusiak B. S. .2019 .Daylight Transport Systems for Buildings at High Latitudes. Journal of Daylighting, 6 : 60-79.
Goharian A.,Mahdavinejad M. .2020 .A Novel Approach to Multi-Apertures and Multi-Aspects Ratio Light Pipe. Journal of Daylighting, 7 : 186-200.
Zazzini P.,Di A.,Crescenzo A.,Giammichele R. .2022 .Daylight Performance of the Modified Double Light Pipe (MDLP) Through Experimental Analysis on a Reduced Scale Model. Journal of Daylighting, 9 : 164-176.
Obradovic B.,Matusiak B. S. .2022 .Illumination and Lighting Energy Use in an Office Room with a Horizontal Light Pipe: Field Study at a High Latitude. Journal of Daylighting, 9 : 209-227.
Zazzini P.,Crescenzo A. Di,Rossitti L. Pio,Mirando R. .2022 .Experimental Analysis on a 1:2 Scale Model of the Modified Double Light Pipe. Journal of Daylighting, 9 : 228-241.
Sönmez N.,Kunduracı A. C.,Çubukçuoğlu C. .2024 .Daylight Enhancement Strategies Through Roof for Heritage Buildings. Journal of Daylighting, 11 : 234-246.
Store Fifth Avenue Apple .2025 .-fifth-avenue-foster-pluspartners (accessed Apr. , 15 : .
Rooflight F100 Circular (LAMILUX). .2025 .- circularlamilux?ad_source=neufert&ad_medium=gallery&ad_name=close-gallery (accessed Apr. , 15 : .
Kittler R.,Perez R.,Darula S. .1998 .A Set of Standard Skies Characterizing Daylight Conditions for Computer and Energy Conscious Design. Final report of the U.S.-Slovak Grant project US-SK 92 052, : .
. .EN 12665:2002 Light and lighting - Basic terms and criteria for specifying lighting requirements. , : .
Garbaruk Yu. V.,Duffie W. A.,Beecman A,Wiley-Intercience Publication A .1974 .(in Ukrainian) I. A. NUWEE PhD dissertation, : .
Garbaruk Yu. V.,Kundrat T. M.,Pugachev E. V. .2011 .The Influence of the Reflectance Coefficient on the Efficiency of Cylindrical Light Shafts, Energy Saving in Construction 1 (. , : 62-67.
Garbaruk T. M.,Kundrat E. V.,Pugachev E. V.,Metropolis S.,Ulam S. .1949 .Comparison of the Efficiency of Cylindrical Light Shafts with Diffuse and Specularly Reflection of Light. J. Amer. statistical assoc, 44(247) : 335-341.
Doucet A. .2001 .. , : .
Fishman G. S.,Algorithms G. S. .1995 .. Monte Carlo: Concepts, : .
0

Citations

0

Downloads

68

Views