No Detail Found!

Comparison of the Early-term Complications and Patency Rates of the Standard (Parachute) and Diamond-shaped End-to-side Anastomosis Techniques in Arteriovenous Fistulas Created for Hemodialysis.

Author(s)
Hakan Yabanoglu Department of General Surgery, Baskent University Adana Teaching and Research Center, Adana, Turkey
Murat Kus Department of General Surgery, Baskent University Adana Teaching and Research Center, Adana, Turkey
Ilker Murat Arer Department of General Surgery, Baskent University Adana Teaching and Research Center, Adana, Turkey
Cagla Bali Department of Anesthesiology and Reanimation, Baskent University Adana Teaching and Research Center, Adana, Turkey
Tevfik Avci Department of General Surgery, Baskent University School of Medicine, Ankara, Turkey
Aydincan Akdur Department of General Surgery, Baskent University School of Medicine, Ankara, Turkey
Kenan Caliskan Department of General Surgery, Baskent University Adana Teaching and Research Center, Adana, Turkey
Abstract
Objective: To compare the early-term patency and complication rates of the end-to-side anastomosis techniques parachute and diamond-shaped techniques in arteriovenous fistulas. Study Design: Prospective randomised study. Place and Duration of Study: Department of General Surgery, Adana Baskent University Application and Research Hospital, Adana, Turkey, between October 2014 and January 2015. Methodology: Patients with end stage renal disease who underwent arteriovenous fistula creation for hemodialysis were grouped into two according to the anastomosis technique performed. Group 1 was composed of the patients undergoing the standard parachute technique and Group 2 consisted of the patients operated with the diamond-shaped anastomosis technique. The two groups were compared with each other with respect to clinical and demographic data, operative and postoperative variables, and complication and patency rates. Results: A total of 56 patients underwent arteriovenous fistula creation. The overall complication rate was 12.5%. The early-term patency rate was higher in the diamond-shaped anastomosis technique than the standard parachute endto-side anastomosis technique. Effective dialysis was established after 4 weeks in 48 (85.7%) patients in the overall study group, 23 (82.1%) in Group 1, and 25 (89.2%) in Group 2. However, there was no significant difference between both the techniques with respect to effectiveness of dialysis. Conclusion: Both end-to-side anastomosis techniques have their own advantages and disadvantages. Using a patientspecific suitable technique rather than a standard technique would be more appropriate in arteriovenous fistulas formation.
Publication Details
Page(s) 597-602
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 28, Issue: 8, Year: 2018

Request the full text from PASTIC

References
USRenal Data System, 2011.,Accessed March 24 -
SungRS,GallowayJ,Tuttle-newhallJE,MoneT,LaengR,FreiseCE, 2008.Organ donation and utilization in the United States,,Am J Transplant 8 922 -34
JenkinsAM,BuistTA,GloverSD, 1980.Medium-term follow-up of forty autogenous vein and forty polytetrafluoroethylene (GoreTex) grafts for vascular access,Surgery 88 667 -72
AhmedI,PansotaMS,TariqM,TabassamSA,SaleemMS, 2012.Surgical outcome and primary failure rate,JUMDC 3 27 -33
GanieFA,LoneH,DarAM,LoneGN,WaniML, 2013.Native arteriovenous fistula is the vascular access of choice for hemodialysis in end stage renal disease,Int Cardiovasc Res J 7 67 -70
MozaffarM,FallahM,LotfollahzadehS,SobhiyehMR,GholizadehB,JabbehdariS, 2013.Comparison of efficacy of side to side versus end-to-side arteriovenous fistulae formation in chronic renal failure as a permanent hemodialysis access,Nephrourol Mon 5 827 -30
NawazS,AliS,ShahzadI,BalochMU, 2013.Arterio venous fistula experience at a tertiary care hospital in Pakistan,Pak J Med Sci 29 161 -5
StanzialeR,LodiM,D'andreaE,SammartinoF, 2011.Arteriovenous fistula: end-to-end or end-to-side anastomosis?,Hemodial Int 15 100 -3
KankoM,SenC,YavuzS,UnalC,AksoyA,BerkiT, 2012.Evaluation of arteriovenous fistulas made with the diamond-shaped anastomosis technique,Med Sci Monit 18 MT67 -70
SenC,AgirH,Iscen D, 2006.Simple and reliable procedure for endto-side microvascular anastomosis: the diamond technique,Microsurgery 26 160 -4
GoksinI,BaltalarliA,OnemG, 2004.Arteriovenöz fistül operasyonlari: erken ve geç dönemde revizyon gerektiren komplikasyonlar,Türk Gögüs Kalp Damar Cerrahisi Dergisi 12 180 -3
FernstromA,HylanderB,OlofssonP,SwedenborgJ, 1988.Longand short-term patency of radiocephalic arteriovenous fistulas,Acta Chir Scand 154 257 -9
SozudogruAN,CangelU, 1999.Hemodializ amaciyla yapilan arteriovenoz fistüllerin kisa ve uzun dönem sonuçlari: Retrospektif klinik çalisma,Türk Gögüs Kalp Damar Cerrahisi Dergisi 7 135 -9
WayneEJ,BrierME,DwyerAC, 2013.Association of maturation period blood pressure with dialysis access patency,Semin Dial 26 90 -6
BaserM,SayarliogluH,DoganE, 2006.Comparison of proximal distal success rate in A-V fistulas settled for hemodialysis,J Van Med 13 42 -5
SolimanM,MorsyM,BagulA, 2015.Modification of the parachute technique to simplify vascular anastomosis in kidney transplantation,Ann R Coll Surg Engl 97 79 -
SenC, 2008.Hasanov A. Comparative geometric analysis of diamond and hole techniques in end-to-side microvascular anastomosis,Microsurgery 28 262 -4
EmrecanB,SacarM,OnemG, 2011.Ekstremiteyi tehdit eden arteriovenöz fistül,Türk Gögüs Kalp Damar Cerrahisi Dergisi 3 440 -2
TedoriyaT,UrayamaH,Katada S, 1995.A survey of vascular access for hemodialysis,Vasc Surg 29 123 -7
MeyerF,MullerJS,BurgerT,HalloulZ,LippertH, 2002.Experiences with ambulatory arteriovenous shunt surgery. A cost-benefit analysis,Chirurg 73 274 -8
KherlakianGM,RoedersheimerLR,ArbaughJJ,NewmarkKJ,KingLR, 1986.Comparison of autogenous fistula versus expanded polytetrafluoroethylene graft fistula for angioaccess in hemodialysis,Am J Surg 152 238 -43
BrimbleKS,RabbatCG,SchiffD,IngramAJ, 2001.The clinical utility of Doppler ultrasound prior to arteriovenous fistula creation,Semin Dial 14 314 -7
Iyem H. Early, 2011.-up results of arteriovenous fistulae created for hemodialysis,Vasc Health Risk Manag 7 321 -5
WaakelJA,HuraibS,MitwalliA, 1994.Hemodialysis vascular access and complications,Vasc Surg 28 107 -13
SimoniG,BonolamiU,CivalleriD,DecianF,BartoliFG, 1994.Endto-end A-V fistula for chronic hemodialysis; 11 years experience,Cardiovasc Surg 2 63 -6
0

Citations

0

Downloads

82

Views