Monitoring of cadmium in drinking water by voltammetry.

Author(s)
R. Ahmed Nuclear Chemistry Division, PINSTECH, P.O: Nilore, Islamabad, Pakistan
T. Yamin Department of Chemistry, Quaid-i-Azam University Islamabad, Pakistan
M. S. Ansari Department of Chemistry, Quaid-i-Azam University Islamabad, Pakistan
Abstract
Cadmium, one of the most harmful elements is toxic at very low levels. The WHO recommended tolerance levels of cadmium in drinking water are 3 mg/L. Different pulse anodic stripping voltammetry (DPASV) is quite a sensitive and accurate analytical technique, which can be employed to measure a number of metals including cadmium well below the tolerance levels in water samples. A DPASV method has been optimized for the analysis of cadmium in water. The initial standardization and optimization procedure using perchloric acid as the supporting electrolyte showed that for different deposition times vs. peak heights the results were linear which indicates that sensitivity of the method can be increased many fold by increasing the deposition times. Calibration curves between different concentrations of cadmium and peak heights are quite linear. A number of drinking water samples collected from various locations of Rawalpindi-Islamabad have been analyzed. The levels of cadmium are in the ranges of 0.5-60 mg/L. Thus some of the samples have higher levels than the recommended values.
Publication Details
Page(s) 7-12
DOI DOI not available
Published Journal: Nucleus, Volume: 40, Issue: 1--4, Year: 2003

Request the full text from PASTIC

0

Citations

0

Downloads

50

Views