This study provides guidelines for the design of a sustainable water supply scheme considering the management of water resources i.e., rainwater harvesting and water conservation. It was based on conducting a feasibility study to evaluate the possible benefits of proposed interventions and performing a cost analysis to check the cost- benefit analysis. Firstly, the water supply system without rainwater harvesting system was designed. Subsequently, rainwater harvesting potential was assessed for residential plots of 3-marla, 5-marla, and 10-marla sizes. The storage tank volume analysis was then performed. The storage tank volume was calculated using four different methods that included Sam Sam Water Rainwater Harvesting Tool Model, General Formula, Ripple Method and Equalization Method. The Sam Sam Water Rainwater Harvesting Model was found to be the most optimum method for the calculation of volume in our scenario. The calculated storage volume was divided into the rain barrel volume and the underground tank volume. Moreover, three cases are developed based on the different water demand % that is considered to be met through harvested rainwater. The Case I included the water demand of gardening, house cleaning and laundry which computes18%of the demand whereas the Case II included the demand for gardening, house cleaning, laundry and toilet flushing which constitutes the 44% demand and finally the Case III included the gardening and house cleaning that builds the 8% of the demand. Case I was selected because the rainwater is not enough to fulfill demand of Case II whereas the demand of Case III is too low, and the majority of rainwater is wasted. Now after the case selection and the storage volume computation the rainwater harvesting system was designed on the SWMM by using the LID of Rain Barrel. The system without and with Rainwater Harvesting System was run and the comparison of both systems is done. The effect on flooding and run-off for 2-year, 5-year and 10-year return period is observed. The implementation of RWHS led to an 8.6% reduction in average water demand and a 17.38% decrease in electricity consumption. The analysis further revealed substantial mitigation of urban peak flooding from individual houses, with reductions of 99.50%, 97.07%, and 91.91% for return periods of 2, 5, and 10 years, respectively, as evaluated using SWMM. At the community (society) level, flooding was reduced by approximately 20-24%. The estimated implementation costs of RWHS for 3, 5, and 10 Marla houses are Rs. 550,253, Rs. 670,890, and Rs. 1,112,283, respectively.