No Detail Found!

Optimizing structural performance of concrete-filled steel tubes: the influence of compaction and cross- sectional shape

Author(s)
Pawar Praveen Department of Civil Engineering, Koneru Lakshmaiah Education Foundation (KL Deemed to be University), Guntur, Vaddeswaram, India
P. Poluraju Department of Civil Engineering, Koneru Lakshmaiah Education Foundation (KL Deemed to be University), Guntur, Vaddeswaram, India
M. V.Chitawadagi School of Civil Engineering, KLE Technological University, Hubballi, Karnataka, India
Md Asif Department of Civil Engineering, Government Polytechnic, Kalaburagi, Karnataka, India
Abstract
In this study, the effects of concrete compaction techniques and different cross-sectional shapes (square, rectangular, and circular) on load-carrying capacity are examined in relation to the structural behavior of concrete-filled steel tube (CFT) columns under axial loading. Because of their exceptional strength, ductility, and capacity to absorb energy, CFT columns are being used more and more in contemporary construction, especially in seismically active areas. A thorough literature review, experimental testing of CFT specimens using various concrete grades (M20, M30, and M40), and comparison of the findings with current design codes (AISC, ACI, and EC4) are all included in the study. The main conclusions show that compacted CFT columns can support loads much higher than their non-compacted counterparts, with circular sections outperforming square and rectangular ones. The study emphasizes how crucial concrete compaction is to improving the performance of CFT columns and offers suggestions for additional research, such as investigating the effects of eccentric loading and using finite element analysis to enhance structural modeling.
Publication Details
Page(s) 1021-1031
DOI DOI not available
Published Journal: ARPN Journal of Engineering and Applied Sciences, Volume: 20, Issue: 14, Year: 2025

Request the full text from PASTIC

Keywords
and thickness, cross section, grade of infill, compaction
References
Kibriya T. .2017 .Performance of concrete filled steel tubular columns. American Journal of Civil Engineering and Architecture, 5(2) : 35-39.
AL-Eliwi B. J. M.,Ekmekyapar T.,AL-Samaraie M. I. A.,Hanifi D. M. .2018 .Behavior of reinforced lightweight aggregate concrete-filled circular steel. , : .
Abdel-zaher A. S.,Abdel-Hafez Y. R.,Tawfic Y. R.,M. E. Y. R. .2020 .Theoretical investigation of concrete field steel hollow section columns. Journal of Advanced Engineering Trends, 39(1) : 63-76.
Yang Y. F.,Han L. H. .2012 .Concrete filled steel tube (CFST) columns subjected to concentrically partial compression, Thin-Walled Structures. , 50(1) : 147-156.
Concrete Institute American,Detroit American,Institute American .1991 .Cold formed steel design manual-load and resistance factor design. ACI 318, : .
Attard M. M.,Setunge S. .1996 .Stress-strain relationship of confined and unconfined concrete. ACI Mat. J, 93(5) : 432-442.
Boue P. .1957 .Concrete filled steel stanchions. Acier Steel No. 9, : 351-356.
Bridge R. Q.,Min R. Q. .1990 .Design of composite columns. Postgraduate Course Notes, : 63-86.
Cai S. .1991 .Influence of moment distribution diagram on load-carrying capacity of CFST columns. Proc., 3rd Int. Conf. on Steel-Concrete Compos. Struct, 113 : 118.
Dowling P. J.,Janss J.,Virdi K. S. .1977 .The design of composite steel-concrete columns. Proc., 3rd Int. Symp. of Stability of Steel Struct.: Introductory Rep., Appendix, : 309-327.
.1992 .Design of composite steel and concrete structures, part 1.1-General rules and rules for buildings. Eurocode 4, : .
Furlong R. W. .1967 .Strength of steel encased beam columns. J. Struct. Div., ASCE, 93(5) : 113-124.
Gardner N. J. .1968 .Use of spiral welded steel tubes in pipe columns. ACI J, 65(11) : 937-942.
Gardner N. J.,Jacobson E. R. .1967 .Structural behavior of concrete filled steel tubes. ACI J, 64 : 404-413.
Grimault J. P.,Janss J. .1977 .Reduction of the bearing capacity of concrete filled hollow sections due to local buckling. Proc., ECCS Colloquium on Stability of Steel Struct., Preliminary Rep, : 175-179.
Guiaux P.,Janss J. .1970 .Buckling behavior of columns made with steel tubes and filled with concrete. MT 65., 70 : .
Imamura T. .1994 .Concrete filled steel tubular columns-Study and construction practice. Proc., 4th ASCCS Int. Conf. on Steel-Concrete Compos. Struct, 84 : 87.
Kavoossi H. R.,and Schmidt L. C. H. R. .1993 .The mechanical behaviour of higher strength concrete confined in circular hollow sections. Proc., 13th Australasian Conf. on the Mech. of Struct. and Mat, : 453-460.
Kilpatrick A. .1996 .The behaviour of high-strength composite concrete columns. , : .
Goder K.,D. K. .1957 .Collapse load tests on concrete filled steel tubes and derivation of design formula. Der Stahlbau, : .
Knowles R. B.,Park R. .1969 .Strength of concrete filled steel tubular columns. J. Struct. Div., ASCE, 95(12) : 2565-2587.
Knowles R. B.,Park R. .1970 .Axial load design for concrete filled steel tubes. J. Struct. Div., ASCE, 96(10) : 2125-2153.
Lin C. Y. .1988 .Axial capacity of concrete infilled cold-formed steel columns. Proc., 9th Int. Spec. Conf. on Cold Formed Steel Struct, : 443-456.
Luksha L. K.,Nesterovich A. P. .1991 .Strength testing of large diameter concrete filled steel tubular members. Proc., 3rd Int. Conf. on Steel-Concrete Compos. Struct, 67 : 71.
Mander J. B.,Priestley M. J. N.,Park R. .1988 .Theoretical stress-strain model for confined concrete. J. Struct. Engrg., ASCE, 114(8) : 1804-1848.
Martinez S.,Nilson A. H.,and Slate F. O. A. H. .1984 .Spirally reinforced high-strength concrete columns. ACI Struct. J, 81(5) : 431-442.
Masuo K.,Adachi M.,Kawabata K.,Kobayashi M.,Konishi M. .1991 .Buckling behaviour of concrete filled circular steel tubular columns using light weight concrete. Proc., 3rd Int. Conf. on Steel- Concrete Compos. Struct, 95 : 100.
Neogi P. K.,Sen H. K.,Chapman J. C. .1969 .Concrete-filled tubular steel columns under eccentric loading. The Struct. Engr., London, 47(5) : 187-195.
Orito Y.,Sato T.,Tanaka N.,Watanabe Y.,ASCE Y. .1987 .Study on the unbonded steel tube composite system. Proc., Compos. Constr. In Steel and Concrete, : 804.
Prion H. G. L.,Boehme J. .1989 .Beam-column behaviour of steel tubes filled with high strength concrete. Proc., 4th Int. Colloquium, North Am. Session on Code Differences around the World, Structural Stability Research Council, : 450.
Rangan B. V.,Joyce M. .1992 .Strength of eccentrically loaded slender steel tubular columns filled with high-strength concrete. ACI Struct. J, 89(6) : 676-681.
Roik E. K.,Bergmann R. .1989 .Harmonisation of the European construction codes. report on Eurocode 4. Rep. EC4/6/89, : .
Sakino K.,Hayashi H. .1991 .Behaviour of concrete filled steel tubular stub columns under concentric loading. Proc., 3rd Int. Conf. on SteelConcrete Compos. Struct, 25 : 30.
Salani H. J.,Sims J. R. .1964 .Behaviour of mortar filled steel tubes in compression. ACI J, 61(10) : 1271-1283.
Sen H. K.,Tubes Division,Steel British .1990 .Concrete filled tubular steel columns. Tubular Structures, 17 : .
Australia Concrete . .. , : .
Structures .1994 .. , : .
0

Citations

0

Downloads

17

Views