No Detail Found!

Improvement of daylight factor model for window size optimization and energy efficient building envelope design

Author(s)
Chahrazed Mebarki Laboratory Built in the Environment, University of Science and Technology Houari Boumediene (USTHB),16111 Algiers,Algeria
Essaid Djakab Laboratory Built in the Environment, University of Science and Technology Houari Boumediene (USTHB),16111 Algiers,Algeria
Abderrahmane Mejedoub Mokhtari Soil Materials and Thermal Laboratory (LMST) University of Science and Technology of Oran Mohammed BOUDIAF,USTOMB -,Algeria
Youssef Amrane Laboratory of Electrical and Industrial Systems, University of Science and Technology Houari Boumediene (USTHB),16111 Algiers,Algeria
Lotfi Derradji National Center of Studies and Integrated Research of the Building, CNERIB,Algiers,Algeria
Abstract
Based on a new approach for the prediction of the Daylight Factor (DF), using existing empirical models, this research work presents an optimization of window size and daylight provided by the glazed apertures component for a building located in a hot and dry climate. The new approach aims to improve the DF model, considering new parameters for daylight prediction such as the orientation, sky conditions, daytime, and the geographic location of the building to fill in all the missing points that the standard DF, defined for an overcast sky, presents. The enhanced DF model is considered for the optimization of window size based on Non dominated Sorting Genetic Algorithm (NSGA II), for heating and cooling season, taking into account the impact of glazing type, space reflectance and artificial lighting installation. Results of heating and cooling demand are compared to a recommended building model for hot and dry climate with 10% Window to Wall Ratio (WWR) for single glazing. The optimal building model is then validated using a dynamic convective heat transfer simulation. As a result, a reduction of 48% in energy demand and 21.5% in CO2 emissions can be achieved. The present approach provides architects and engineers with a more accurate daylight prediction model considering the effect of several parameters simultaneously. The new proposed approach, via the improved DF model, gives an optimal solution for window design to minimize building energy demand while improving the indoor comfort parameters.
Publication Details
Page(s) 204-221
Published Journal: Journal of Daylighting, Volume: 8, Issue: 2, Year: 2021

Request the full text from PASTIC

Keywords
Energy demand, daylight factor, Daylighting, Glazed area
References
Energt Agency I. World Energy International,Outlook International .2018 .. , : .
APRU. LA CONSOMMATION ÉNERGÉTIQUE FINALE Chiffres clés Année .2017 .. , : .
Boudali Errebai F.,Derradji L.,Limam A.,Amra M. .2021 .Energy efficient and economic profitability between standard and high energy performance dwellings in a semi-arid climate. International journal of Ambient Energy, : .
Tabadkani A.,Roetzel A.,Tsangrassoulis A. .2020 .A review of automatic control strategies based on simulations for adaptive facades. Building and Environment, 175 : 106801.
Mesloub A. .2020 .Daylighting of Light Shelf Photovoltaics ( LSPV ) for Office Buildings in Hot Desert-Like Regions. Applied sciences 10, : 7959.
Mesloub A.,Ghosh A. .2020 .Energy and Daylighting Evaluation of Integrated Semitransparent Photovoltaic Windows with Internal Light Shelves in Open-Office Buildings. , : 0-21.
Mesloub A.,Ghosh A.,Touahmia M. .2020 .Performance Analysis of Photovoltaic Integrated Shading Devices ( PVSDs ) and Semi-Transparent Photovoltaic ( STPV ) Devices Retrofitted to a Prototype O ffi ce Building in a Hot Desert Climate. Sustainability, 12 : 10145.
Alwetaishi M. .2019 .Impact of glazing to wall ratio in various climatic regions: A case study. Journal of King, 31 : 6-18.
Rathi P. .2012 .Optimization of Energy Efficient Windows in Office Buildings. , : .
Krarti M. .2005 .A simplified method to estimate energy savings of artificial lighting use from daylighting. Building and Environment, 40 : 747-54.
. .CYPE catalogue cost generater. , : .
Gholami H. .2020 .Economic analysis of BIPV systems as a building envelope material for building skins in Europe. Energy, 204 : 117931.
Huang D,Yu T. ScienceDirect .2017 .ScienceDirect Study on Energy Payback Time of Building Integrated Photovoltaic System. Procedia Engineering, 205 : 1087-92.
Saint Gobain India Pvt. Ltd. Glass,Business Gobain India Pvt. Ltd. Glass .2018 .. SUSTAINABILTY REPORT, : .
'ENVIRONNEMENT L,MDEDER L .2017 .. , : .
CPDN-ALGERIE .2015 .Contribution Prévue Déterminée au niveau National, (. , : .
Eljojo A. .2017 .Effect of Windows Size , Position and Orientation on the Amount of Energy Needed for Winter Heating and Summer Cooling. Journal of Engineering Research and Technology, 1 : 0-8.
Burmaka V.,Tarasenko M.,Kozak K.,Omeiza A. .2020 .Effective Use of Daylight in Office Rooms. Journal of Daylighting, 7 : 154-66.
Karabay H.,Arici M. .2012 .Multiple pane window applications in various climatic regions of Turkey. Energy and Buildings, 45 : 67-71.
AS .2015 .Muhaisen,HR. Dabboor, Studying the Impact of Orientation , Size , and Glass Material of Windows on Heating and Cooling Energy Demand of the Gaza Strip Buildings. Journal of Architecture and Planning, 27 : 1-15.
Carlucci S.,Causone F.,Rosa F De,Pagliano L. .2015 .A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design. Renewable and Sustainable Energy Reviews, 47 : 1016-33.
CF. Reinhart O.,Walkenhorst O. .2001 .Validation of dynamic RADIANCE-based daylight simulations for a test of ® ce with external blinds. Energy & Buildings, 33 : 683-97.
Sun C,Liu Q,Han Y.,Many-Objective Optimization Y. .2020 .Design of a Public Building for Energy, Daylighting and Cost Performance Improvement. applied sciences. 10, : 2435.
Sudan M.,Al-Helal M. .2015 .A daylight factor model under clear sky conditions for building: An experimental validation. Solar Energy, 115 : 379-89.
Alshaibani .1996 .Prediction of interior daylight under clear sky conditions. [26] [28] [30] [32] [34] [36] [38] [39] [41] [43] [44] [45] [46] KA, : .
Abdelhakim M.,Lim Y.,Kandar Z. .2019 .Optimum Glazing Configurations for Visual Performance in Algerian Classrooms under Mediterranean Climate. Journal of Daylighting, 6 : 11-22.
Nabil A.,Mardaljevic J. .2006 .Useful daylight illuminances: A replacement for daylight factors. Energy and Buildings, 38 : 905-913.
M. Ghazi .2009 .The Use of Useful Daylight Illuminance (UDI) to Test New Designs for Improving Daylight Performance of Office Buildings in Dubai-. , : .
Kharvari F. A .2020 .Field-validated Multi-objective Optimization of the Shape and Size of Windows Based on Daylighting Metrics in Hot-summer Mediterranean and Dry Summer Continental Climates. Journal of Daylighting, 7 : 222-37.
Mardaljevic J.,Andersen M.,Roy N.,Christoffersen J.,Gateway T. .2012 .Daylighting metrics : is there a relation between useful daylight illuminance and daylight glare probability ?. In: Proceedings of the Building Simulation and Optimization Conference BSO12, : 8.
Aishaibani K. .2015 .Average daylight factor for the ISO / CIE Standard General Sky. Lighting Research & Technology, 48 : 742-754.
Li DHW. .2006 .Average daylight factor for the 15 CIE standard skies. Lighting Research and Technology, 39 : 37-152.
Taylor P.,Illuminance S.,Treado S. .2013 .Measurements of sky luminance , sky illuminance , and horizontal solar radiation. Journal of the Illuminating Engineering Society, 12 : 37-41.
Aydinli S.,Krochmann J.,Taylor J. .1983 .Data on daylight and solar radiation. Draft for CIE TC 4.2, : .
Chroscicki W. .1971 .Calculation methods of determining the value of daylight's intensity onthe ground of photometrical and actinometrical measurements. Proc. CIE, : .
Yadoya M.,K. M. .1979 .Kimura Research of Planning and Energy Evaluation of Natural Illumination with Direct Sunlight: Part 1: Effect of Outside Reflective Louvers. Architectural Institute of Japan Proceedings, 283 : 87-97.
PJ. Littlefair .1985 .The luminous efficacy of daylight: a review. Lighting Research & Technology, 17 : 162-82.
ASHRAE Fundamentals Handbook .2003 .. FENESTRATION:Chapter, 30 : .
DRG.Hunt .1979 .The use of artificial lighting in relation to daylight levels and occupancy. Building and Environment, 14 : 21-33.
PJ. Littlefair .1990 .Predicting annual lighting use in daylit buildings. Building and Environment, 25 : 43-53.
Attia S.,Hamdy M.,Carlucci S. .2013 .Assessing gaps and needs for integrating building performance optimization tools in net zero energy buildings design. Energy & Buildings, 60 : 110-24.
Deb K.,Member A.,Pratap A.,Agarwal S.,Meyarivan T.,A Fast T. .2002 .. and Elitist Multiobjective Genetic Algorithm, 6 : 182-97.
PR.Boyce P.,Raynham P. .2009 .. The Society of Light and Lighting Handbook, Society of Light and Lighting, 44 : 1-316.
CIBSE .1999 .. , : .
.2012 .. EN 12464, : 11.
Yusoff Y. .2011 .Overview of NSGA-II for Optimizing Machining Process Parameters. Procedia Engineering, 15 : 3978-3983.
Belniak S. .2013 .The influence of the building shape on the costs of its construction. Journal of Financial Management of Property and Construction, 18 : 90-102.
SP.Allan Ashworth .2015 .. Cost Studies of Buildings, : .
Zhai Y.,Wang Y.,Huang Y.,Meng X. .2019 .A multi-objective optimization methodology for window design considering energy consumption, thermal environment and visual performance. Renewable Energy, 134 : 1190-1199.
Isobe M.,Matsuhiro K. .2017 .Effect of Orientation of Window on Building Heat Load : Perspective of N-E India Effect of Orientation of Window on Building Heat Load : Perspective of N-E India. , : 1-8.
Piotrowska E.,Borchert A. .2017 .Energy consumption of buildings depends on the daylight. In: E3S Web of Conferences, Energy and Fuels, : .
Vanhoutteghem L.,Svendsen S. .2015 .Impact of façade window design on energy , daylighting and thermal comfort in nearly zeroenergy houses. Energy and Buildings, 102 : 149-156.
Gagne J.,Andersen M. .2012 .A generative facade design method based on daylighting performance goals. Journal of Building Performance Simulation, 5 : 37-41.
Technology C for B,Laboratory NE,Standards NB,Solar Radiation .1981 .. and Illumination, : .
Dervishi S.,Mahdavi A. .2013 .A simple model for the derivation of illuminance values from global solar radiation data. Building Simulation, 6 : 379-83.
GOBAIN. MEMENTO SAINT .2007 .. , : .
Tzempelikos A. .2007 .The impact of shading design and control on building cooling and lighting demand. Solar Energy, 81 : 369-382.
Engineering Society of North America Illuminating,Lighting I. IESNA,Handbook I. IESNA .2000 .. , : .
Bakhtyar B.,Elayeb O. .2015 .The role of window glazing on daylighting and energy saving in buildings. Renewable and Sustainable Energy Reviews, 42 : 323-343.
Gratia E.,A.De Herde E. .2003 .Design of low energy office buildings. Energy and Buildings, 35 : 473-91.
SK.Alghoul .2017 .Energy Consumption in Buildings: A Correlation for the Influence of Window to Wall Ratio and Window Orientation in Tripoli, Libya. Journal of Building Engineering, 11 : 82-86.
BG.Headquarters .2014 .-1 Energy performance of buildings - Module M9 - Energy requirements for lighting - Part 1. , 44 : .
Final report .2018 .. International comparison of fossil power efficiency and CO, 2 : intensity.
APRU .2015 .. , : 1-24.
Reinhart N.,Jones L.,Christoph F. . .FAST DAYLIGHT COEFFICIENT CALCULATION USING GRAPHICS. InProceedings of BS2015: 14th Conference of International Building Performance Simulation Association., : .
0

Citations

0

Downloads

9

Views