Passive energy saving through thermal retrofitting of existing government office building envelopes - case study for office-research building in Cairo, Egypt

Author(s)
A. M. Abdel-Wahab National Research Centre, Engineering and Renewable Energy Research Institute, Department of Civil Engineering,Cairo,Egypt
Ayman M. H. El-Alfy National Research Centre, Engineering and Renewable Energy Research Institute, Department of Civil Engineering (Architectural),Cairo,Egypt
Abstract
Egypt used several million kilowatts per hour of electrical power in 2023. According to 2022 data, public utilities and agencies used 15% of Egypt's power. Most of Cairo's government buildings built in the 50th and the 60th of the last century are composed of reinforced concrete structure skeletons, flat concrete roofs, and burnt brick exterior and interior walls. At that time, building energy efficiency was not a priority. Thus, uninsulated building envelopes were built. Nowadays, renovating buildings requires increasing energy efficiency. Previous research showed that lack of thermal insulation in roofs, walls, window solar heat gain, and window frames thermal bridging increases heating and cooling costs. The current research aims to enhance existing buildings energy saving by improving thermal insulation of its envelope components. The existing research building in Cairo was assessed for environmental factors to accomplish the research goal. The research used a three-dimensional (3D) terrestrial laser scanner to assess building facades for creating an environmental study model. The research used the building office top floor construction as a comparative environmental simulation using (Design builder® version6 software) as a base case for yearly energy consumption due to heating and cooling loads, followed by improving the thermal insulation of each building element individually in the base environmental model and comparing its effect on annual energy saving percentage, then applying all of the best annual energy saving building envelope element thermal insulation retrofitting techniques to the improved building model. The research results showed that improving roof thermal insulation saves 33.5% of the yearly top floor total electrical energy, 12% for exterior walls, 0.75% for window glazing, and 1.56 % by retrofitting window frames. Applying all of the best energy-saving thermal insulation retrofit techniques to the whole structure saved 31% of annual energy consumption.
Publication Details
Page(s) 1080-1104
DOI DOI not available
Published Journal: ARPN Journal of Engineering and Applied Sciences, Volume: 19, Issue: 17, Year: 2024

Request the full text from PASTIC

Keywords
Energy Saving, Thermal Insulation, and 3D terrestrial laser scanner, thermal comfort zone, building envelope
References
National Climate Change Strategy (NCCS Egyptian .2024 .. , : .
Frontczak M.,Wargocki P. M. .2010 .Literature survey on how different factors influence human comfort in indoor environments. Building and environment, 10(4) : 922-937.
Engineers AirConditioning,Circle NE . .-2010 (Supersedes ANSI/ASHRAE Standard 55-2004) Includes ANSI/ASHRAE addenda listed in Appendix IAmerican Society of Heating, Refrigerating. , 30329 : .
Al-Azri N. A.,Zurigat Y. H.,Al-Rawahi N. Z. .2013 .Development of bioclimatic chart for passive building design. International Journal of Sustainable Energy, 32(6) : 713-723.
. .[5] Climate consultant version consultant. informer.com/6, : .
.2024 .. April, : .
.2005 .[7] The permanent committee for preparing the Egyptian Code to improve the efficiency of energy use in Buildings: Egyptian Code to improve the efficiency of energy use in buildings. ECP, 306 : .
.1998 .The permanent committee for preparing general Egyptian specifications for construction items. Volume two: the General Specifications and basic routine work - Part Ten (Requirements for the basics of design and implementation): Specifications of thermal insulation work items. , : .
El-Darwish I.,Gomaa M. .2017 .Retrofitting strategy for building envelopes to achieve energy efficiency. Alexandria Engineering Journal, 05(4) : 579-589.
Fathy N.,Ibtehal N. .2023 .The role of buildings energy modelling tools (BEM) in improving Envelope efficiency: a case study of an existing educational building. Engineering Research Journal, 179 : 75-99.
Hamed R. E. .2023 .Climate-Adaptable Building Envelope Materials. Journal of Survey in Fisheries Sciences, 10(3S) : 3665-3679.
Mujeebu M. A.,Ashraf N.,Alsuwayigh A. H. .2016 .Effect of nano vacuum insulation panel and nanogel glazing on the energy performance of office building. Applied energy, 04 : 141-151.
Seghier T. E.,Lim Y. W.,Harun M. F.,Ahmad M. H.,Samah A. A.,Majid H. A. .2022 .BIM-based retrofit method (RBIM) for building envelope thermal performance optimization. Energy and buildings, 256 : 111693.
William M. A.,Suárez-López M. J. M. A.,Soutullo S.,Hanafy A. A. .2021 .Techno-economic evaluation of building envelope solutions in hot arid climate: A case study of educational building. Energy Reports, 7 : 550-558.
Atef Faggal A.,Mohamed Moustafa A.,Arafat Yasser,M. Yasser .2019 .effect of different windows' glazing types on energy consumption of a residential building in a hot-arid climate Case Study: Residential Building in New Cairo City. JES. Journal of Engineering Sciences, 47(5) : 706-719.
Djedjig R.,El Ganaoui M.,Belarbi R.,Bennacer R. .2017 .Thermal effects of an innovative green wall on building energy performance. Mechanics & Industry, 18(1) : 104.
He Y.,Yu H.,Ozaki A.,Dong N. .2020 .Thermal and energy performance of green roof and cool roof: A comparison study in Shanghai area. Journal of Cleaner Production, 267 : 122205.
Kolaitis D. I.,Malliotakis E.,Kontogeorgos D. A.,Mandilaras I.,Katsourinis D. I.,Founti M. A. .2013 .Comparative assessment of internal and external thermal insulation systems for energy efficient retrofitting of residential buildings. Energy and buildings, 64 : 123-131.
Abdel-Gawwad A. K.,El-Sherbiny Y. M. .2011 .A New Approach for Façade Documentation Using Laser Scanner. Australian Journal of Basic & Applied Sciences, 5(5) : 1080-1085.
El-Tokhey M.,Abdel-Gawad A. K.,Mogahed Y.,El-Maghraby A. M. .2013 .Accuracy assessment of laser scanner in measuring and monitoring deformations of structures. , 26(2) : 144-151.
Amer H. A.,Shaker I. F.,Ragab A. F.,Abdel-Gawad A. K.,Mogahed Y. M. .2077 .Ranges Effect on the Tx5 Laser Scanner Measurements Accuracy. Middle East Journal of Applied Sciences ISSN, 4613- 09(01) : 40-49.
Eissa A. M.,Shaker I. F.,Abdel-Wahab A. M.,Awad A. A. I. .2022 .Integration of multi-photos and laser scanner data to form a complete 3d model. Ain Shams Engineering Journal, 101952(5) : 101952.
Nap M.,Chiorean S.,Cira C.,Păunescu V.,Suba E.,Sălăgean T. .2022 .Non-Destructive Measurements for 3D Modeling and Monitoring of Large Buildings Using Terrestrial Laser Scanning and Unmanned Aerial Systems. , 23(12) : 5678.
Marzouk M.,El-Bendary N. .2022 .Facility management of gas turbine power plants using 3D laser scanning. HBRC Journal, 10(1) : 73-83.
Moyano J.,Justo-Estebaranz Á,Nieto-Julián J. E.,Barrera A. O.,Fernández-Alconchel M. .2022 .Evaluation of records using terrestrial laser scanner in architectural heritage for information modeling in HBIM construction: The case study of the La Anunciación church (Seville). Journal of Building Engineering, 62 : .
Arjmand M.,Jung J.,Olsen M. J.,Lassiter H. A.,Jafari M. .2023 .Conceptual Design of Advanced Construction Progress Monitoring with Terrestrial and Robotic Laser Scanning Systems. FIG International Federation of Surveyors (FIG, : .
. .. , : .
Kou R.,Zhong Y.,Kim J.,Wang Q.,Wang M.,Chen R.,Qiao Y. .2019 .Elevating low-emissivity film for lower thermal transmittance. Energy and Buildings, 193 : 69-77.
0

Citations

0

Downloads

72

Views