Replacement of tubular fluorescent lamps with tubular leds lamps and daylight integration in classrooms and laboratories

Author(s)
Manal A. Haridy Photometry and Radiometry Division, National Institute of Standards (NIS),Giza,Egypt
Abstract
The quality of the lighting influences greatly our ability to perform work in an enclosed space. Some characteristics of light source are vital in this regard. LED tubular lamps have a number of advantages over normal household and office applications. Tubular LED lamps installation in place of fluorescent lamps has quite a number of advantages. Tubular LEDs do not have mercury in them hence environmentally friendly unlike the little mercury contents in fluorescent tubes. The other advantage is that tubular LEDs emit directional lighting. This helps in reducing the dissipation of light in those fixtures and areas that do not need it, hence better efficiency-about 40% more efficient in comparison to tubular fluorescent lamps. Further, they offer quality light with diverse color temperatures that eliminate flicker-related discomforts such as eye strain, headache, and migraine. Tubular LEDs also have a longer life, adding to their advantages as better options for lighting. Obviously, the superiority of natural light is the best source of illumination, which corresponds well to the response of the human eyes. Daylight tends to have a positive impact on occupants, enabling them to feel lively and bright in their environment. The established advantages of daylight include the enrichment of visual comfort, ensuring health, and increasing overall productivity of the occupants within a building. The paper focuses on the integration of natural daylight by artificial light availability through tubular LED lamps. It investigates the daylight factor with materials of tested two groups of six tubular LED lamps, where 60cm/9 Watt and 120cm/18 Watt, and another group of six tubular fluorescent lamps with 60cm/18 Watt and 120cm/36 Watt. The experiment was composed of two sets of six tubular LED lamps (60cm with 9W and 120cm with 18W) and another set of six tubular fluorescent lamps (60cm with 18W and 120cm with 36W). The measurement was performed by a Spectroradiometer Ocean Optics HR 2000 with 4.7 % uncertainty, and the photometric bench was used for measurement of spectral output. The tubular LEDs and fluorescent lamps irradiance and illuminance were measured using UVA/B silicon detector and Luxmeter detector arrangements, respectively, with 5.2% and 6% uncertainties, respectively. Some of the derived key parameters are daylight factor ratio, UVA power to luminous flux-K for tubular fluorescent lamps, spectral power distribution, and illumination levels. Daylight and tubular LED lamps integration was also determined. While the maximum value detected is less than the safe limit for human health, there is an impact on human health if these types of lamps are used. It follows that tubular LEDs should be used instead of tubular fluorescent lamps to minimize the impact on UVA to human health and the environment.
Publication Details
Page(s) 350-361
DOI DOI not available
Published Journal: ARPN Journal of Engineering and Applied Sciences, Volume: 19, Issue: 6, Year: 2024

Request the full text from PASTIC

Keywords
Illuminance, UVA radiation, tubular fluorescent lamp, irradiance tubular LEDs lamp, daylight factor, spectral power distribution (SPD), uncertainty budget
References
Hathaway W.E. .1992 .A study into the effects of types of light on children-A case of daylight robbery. , : .
. .Heschong schools. , : 1999.
Najib T.,Al-Ashwal T.,Manag T. .2018 .The Impact of Daylighting-Artificial Lighting Integration on Building Occupants Health and Performance. & Appl.Sci. & Techn. 9, (1906) : 9642.
Manal A.,Haridy A. .2015 .Uncertainty Estimation of Spectral Mismatch Correction Factor for Incandescent Lamps. Int. J. Curr. Res. Aca. Rev, 3(7) : 262-273.
Manal A.,Haridy A. .2023 .Comparative Study of Spectral Mismatch Factor, Color Parameters, and Uncertainty Evaluations for Different Outdoor Lamps. International Journal of Engineering and Science, 13(12) : 74-84.
.1984 .International Electrotechnical Commission (IEC). Spectroradiometric measurement of light sources. , : .
.2012 .Standard test method for calibration of a spectroradiometer using a standard source of irradiance. , : .
Kertil J. .1969 .Report on photometric measurements and instruction notes for calibration of photometric standards. , : .
.1993 .International Organization for Standardization (ISO), Guide to the expression of uncertainty in measurement.. , : .
.2007 .United Kingdom Accreditation Service (UKAS), the expression of uncertainty and confidence in measurement, 2nd edn. , : .
Samaa M.,Ahmed M.,Monem A. Soltan .2015 .Radiometric Technique to Assess the Qualification of Phototherapy Luminaire for Jaundice Treatment. Medical Science, 5(7) : 428-430.
0

Citations

0

Downloads

35

Views