Degradation in piezoelectric materials properties due to extensive electrical and thermal cycling is a common phenomenon, which some time alter their internal characteristics. The degradation in properties can affect the function and efficiency of instruments in which these materials are being used. Therefore, it becomes important to identify the extent of changes in performance when exposed to different types of solutions. A piezoelectric ceramic disc was exposed to 3 different solutions, ordinary water, de-ionized water and a solution of NaCI. The PZT (Lead Zirconate Titanate) was immersed in these solutions at 800C and performance characteristics recorded for different frequencies. After effects of the immersed disc due to three different solutions have been analyzed and it is observed that the PZT ceramic is sensitive to the type of water, but regains its original performance characteristics within short period of time. Thin PZT Disc after immersion in NaCI solution in regaining its maximum output voltage in longer period as compared to ordinary and de-ionized water.