Abstract
Modern Telecom Sector is eventually facing exceptionally tough challenges because of continuous and unexpected increase in power density requirement for the communicating machinery and equipment. To fulfil the power requirements for the equipment, a significant architecture and an optimal technique must be introduced. In this paper, a microcontroller-based optimization use of power-density has been carried out. Meeting above requirements, various equipment and electronic devices are employed. We have designed a microcontroller-based system via PROTEUS Virtual System Modeling to acquire efficient and effective results. The main focus of our work is to supply the power to Telecom equipment in meantime. The power is feeding on batteries and DG (Diesel Generator) set, depending on the condition of the power requirements. The changeover operations are performed by different relays, which are dully programmed via a microcontroller in Keil software. The power capacity of Telecom ((Telecommunication) equipment is ranged from 39-48 Volts DC. The rectification process is done by switch mode rectifiers instead of linear rectifiers. Because the switch-mode rectifier technology has brought fabulous improvements in power density as compared to linear rectifiers. This is done via simulation of the smart switch in PROTEUS software. The outcomes of the proposed system are costeffective in terms of fuel consumption of DG.
Publication Details
Page(s) 209-220
Published Journal: Mehran University Research Journal of Engineering and Technology, Volume: 38, Issue: 1, Year: 2019

Request the full text from PASTIC

References
Kwasinski, 2006.Configuration Analysis  of  a  Microgrid-Based  Telecom  Power  System”, 1 -8
ATmega8,January, 2019.µvision  (Get  Started)  (Accessed  on  September, 38 22 -0
Chukwubuikem, N.M., Ekene, M.S., and Godwin, U., “A Cost-Effective Approach to Implementing Change Over System”, Academic Research International, Volume 2, No. 2, pp. 62-72, 2012.
Kupriyanov, A., “Utilizing Hybrid Power Systems in Telecom Applications”, UNIPOWER Powering Technologies, 2016. http://unipowerco.com/pdf/ utilizing_hybrid-an.pdf
Ezema, L.S., Peter, B.U., and Harris, O.O., “Design of Automatic Change Over Switch with Generator Control Mechanism”. Academic Research International, Part-I: Natural and Applied Sciences, Volume 3, No. 3, pp. 125-130, 2012.
Cugnet, M., Sabatier, J., Laruelle, S., Grugeon, S., Sahut, B., Oustaloup, A., and Tarascon, J.M., “On Lead-Acid- Battery Resistance and Cranking-Capability Estimation”, IEEE Transaction on Industrial Electronics, Volume 57, No. 3, pp. 909-917, 2010.
Fakham, H., Lu, D., and Francois, B., ”Power Control Design of a Battery Charger in A Hybrid Active PV Generator for Load following Applications”, IEEE Transaction on Industrial Electronics, Volume 58, No. 1, pp. 85-94, 2011
Sachan, A., “Microcontroller Based Substation Monitoring and Control System with GSM Modem”, IOSR Journal of Electrical and Electronics Engineering, Volume 1, No. 6, pp. 13-21, 2012
Belvedere, B., Bianchi, M., Borghetti, A., Nucci, C.A., Paolone, M., and Peretto, A., “A Microcontroller-Based Power Management System for Standalone Micro Grids with Hybrid Power Supply”, IEEE Transactions on Sustainable Energy, Volume 3, No. 3, pp. 422-431, 2012
Mandaliya, H., Mankodi, P., and Makwana, B., “Microcontroller Based DDS Function Generator”, International Journal of Engineering Science and Innovative Technology, Volume 2, No. 1, pp. 483-486, 2013
Thiyagarajan, V., and Palanivel, T.G., “An Efficient Monitoring of Substations Using Microcontroller Based Monitoring System”, Volume 4, No. 1, pp. 63-68 2010
Socher, G., “A Microcontroller Based Dc Power Supply”, Linux Focus, Article Number 251, (Accessed on August 2016).
Shameer, V.H., and Shameer, K.M., “Proactive Condition Monitoring Systems for Power Plants”, International Journal of Scientific and Research Publications, Volume 3, No. 11, pp. 1-5, 2013
Thomas, M.G., “Powering Telecom and Info Technology Systems”, Power Quality Archive content from Electrical Construction & Maintenance Magazine, 2001.
Guerrero, J.M., Hang L., and Uceda, J., “Control of Distributed Uninterruptible Power Supply Systems”, IEEE Transactions on Industrial Electronics, Volume 55, No. 8, pp. 2845-2859, Aug. 2008.
Fraisse, M., and Buchsbaum, L., “Environment Friendly High Quality, High Availability Telecom Power Plant Architecture”, International Telecommunication Energy Conference, pp. 463-469, 2002.
0

Citations

0

Downloads

52

Views