Abstract
The intent of study is to establish a criterion for the experimental setup of rasterstereography, one that is more efficient, simple, accurate and precise to examine and analyse the curvature of the object or the subject. Firstly, the setup is needed to be calibrated and for this purpose we considered a reference plane, eleven cylinders of different diameter ranging from 30-119mm were used for calibration of curvature maps of cylinders and cylindrical objects through the regression line. Further this model was tested on subjects and for that we reckoned cylindrical body parts of boys and a total of 30 college students were involved as subjects in this process. The body parts to be measured had curvature like cylinders of different diameters ranging from 42-120mm. The distortion of raster grid was observed, quantified and recorded with the help of different tools and results were established. The regression line was obtained between the measured (x) and computed (y). The standard error of the cylindrical object was 0.04 and that of cylindrical body parts of subjects was 0.0407. This technique was validated through the coefficient of correlation for objects and subjects which was found to be 0.99982 and 0.999141 respectively. Accuracy and Precision were also calculated for this model, which were 99.60% accurate and 99.49% precise. Curvature maps were found more than 99%. This technique is inexpensive, reliable, reproducible and may be installed easily in hospitals to examine appraise body shape, composition and deformities of young men.
Publication Details
Page(s) 197-208
Published Journal: Mehran University Research Journal of Engineering and Technology, Volume: 38, Issue: 1, Year: 2019

Request the full text from PASTIC

References
Frobin , W.,Hierholzer,PhotogrammetricEngineering, 1981.Rasterstereography: A Photogrammetric Method for Measurement of Body Surfaces”, 47 1717 -1724
Frobin , W.,Hierholzer, 1983.Photogrammetric Method for Measurement of Body Surfaces”,Journal of Biological Photogrammetric 5 7 -11
Hierholzer , E.,Schier , F, 1986.Rasterstereography in the Measurement and Postoperative Follow-Up of Anterior-Chest-Wall Deformities”,Kinderchir 41 267 -71
Arffa , R.C.,Warnicki , J.W.,Rehkopf , P.C., 1989.,Refractive Corneal Surgical 5 414 -27
Naufal , S.C.,Hess , J.S.,Friedlander , M.H.,Grand , N.S., 1997.Rasterstereography-Based Classification of Normal Corneas”,Journal of Cataract Refractive Surgical 23 143 -49
Hierholzer , E.,PhotogrammetricEngineering, 1994.Calibration of a Video Rasterstereographic System”, 60 745 -750
Drerup , B.,Hierhoher,ClinicalBiomechanics, 1994.Back-Shape Analysis using Video Rasterstereography and 3DReconstruction of the Spinal Shape”, 9 28 -36
Zubairi , J.A.,Kamal , M.M., 1997.Methodology for Spinal-Deformity Detection using Rasterstereography”,Proceedings of IEEE International Conference on Intelligent Processing Systems 97 1528 -1531
Zubairi , J.A., 2002.Applications of Computer-Aided Rasterstereography in Spinal-Deformity Detection”,Image and Vision Computing 20 319 -324
Drerup , B.,Ellger , B.M.,Bentrup , F.M.,Hierholzer, 2001.Functional Rasterslereographic Images: A New Method for Biomechanical Analysis of Skeletal Geometry”, 30 242 -50
Guarnieri , F.A.,Guarnieri , J.C., 2002.Comparison of Placido-Based, Rasterstereography and Slit-Scan Corneal Topography Systems”,Journal of Refract Surgical 18 169 -76
Hackenberg , L.,Hierholzer , E.,Liljenqvist , U., 2002.Accuracy of Rasterstereography Versus Radiography in Idiopathic Scoliosis after Anterior Correction and Fusion”,Studies in Health Technology, Information 91 241 -245
Hackenberg , L.,Hierholzer , E.,Potzl , W.,Gotze , C.,Liljenqvist , U.,ClinicalBiomechanics, 2003.Rasterstereographic Back-Shape Analysis in Idiopathic Scoliosis after Anterior Correction, 18 1 -8
Schroeder , J.,Reer , R.,Braumann , K.M., 2015.Video Rasterstereography Back Shape Reconstruction: Reliability Study for Sagittal, Frontal, and Transversal Plane Parameter”,European Spine Journal 24 262 -269
Yoon , S.Y.,Seul , K.Y.,DaGam,L. , and Dae,S.P., 2016.Reliability and Validity of Rasterstereography Measurement for Spinal Alignment in Healthy Subjects”,Physical Therapy Rehabilitation Science 5 22 -28
Anne , T.F.,Alice , B.M.,Sylviane , H.,Pierre , L.,Stephane , A.,Romain , D., 2017.Validity and Reliability of Spine Rasterstereography in Patients with Adolescent Idiopathic Scoliosis”,Spine 42 98 -105
0

Citations

0

Downloads

37

Views