Energy and Exergy Analysis of a Coal Fired Power Plant.

Author(s)
Sumeet Kumar Department of Mechanical Engineering, Mehran University of Engineering & Technology, Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mir’s
Dileep Kumar Department of Mechanical Engineering, Mehran University of Engineering & Technology, Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mir’s
Rizwan Ahmed Memon Department of Mechanical Engineering, Mehran University of Engineering & Technology, Jamshoro, Pakistan
Majid Ali Wassan Department of Mechanical Engineering, Mehran University of Engineering & Technology, Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mir’s
Abstract
In this paper, energy and exergy analysis has been conducted on a subcritical coal fired power plant of Wisconsin Power and Light Company, USA to investigate the steam cycle energy and exergy efficiency. The cycle is analyzed by developing a mathematical model using its operating and design parameters. The analysis is performed using EES (Engineering Equation Solver). The energy analysis shows that major share of energy loss occurs in condenser i.e. 72% of total cycle energy loss, whereas, exergy analysis shows that 83.09% total exergy destruction of cycle occurs in boiler.Furthermore, the simulation results are compared with actual with an absolute error of 3.1%. Additionally, the parametric study is performed to examine the effects of various operating parameters such as main steam pressure and temperature, condenser pressure, terminal and drain cooler temperature difference on net power output, energy andexergy efficiency of cycle. The parametric study shows that the plant has maximum energy and exergy efficiencies at steam pressure of 2500psi, condenser pressure of 1.0psi and main steam temperature of 1100oF. Furthermore, these parameters do not seem to change energy and exergy efficiencies significantly.
Publication Details
Page(s) 611-624
Published Journal: Mehran University Research Journal of Engineering and Technology, Volume: 37, Issue: 4, Year: 2018

Request the full text from PASTIC

References
Kaushik , S.C.,Reddy , V.S.,Tyagi , S.K., 2011.Energy and Exergy Analysis of Thermal Power Plants: A Review”, Renewable and Sustainable Energy Reviews, 15 1857 -1872
Kumar , D.,Memon , R.A.,Memon , A.G.,Volume36, 2017.“Energy Analysis of Selected Air Distribution System of Heating, Ventilation and Air Conditioning System: A Case Study of a Pharmaceutical Company”,No. 3 746 -756
Ramadan , M.,Ali , S.,Bazzi , H.,Khaled , M., 2017.New Hybrid System Combining TEG, Condenser Hot Air and Exhaust Airflow of All-Air HVAC Systems”,Case Studies in Thermal Engineering 10 154 -160
Hasti , S.,Aroonwilas , A.,Veawab , A.,EnergyProcedia, 2013.Exergy Analysis of Ultra Super-Critical Power Plant”, 37 2544 -2551
US Energy InformationAdministration, 2017.,International Energy Outlook 07 07 -
Uysal , C.,Kurt , H.,Kwak, 2017.Exergetic and Thermoeconomic Analyses of a Coal-Fired Power Plant”,International Journal of Thermal Sciences 117 106 -120
Yang , Y.,Wang , L.,Dong , C.,Xu , Morosuk, G.,Tsatsaronis,AppliedEnergy, 2013.“Comprehensive Exergy-Based Evaluation and Parametric Study of a Coal-Fired UltraSupercritical Power Plant, 112 1087 -1099
Kumar , D.,Memon , R.A.,Memon , A.G.,Tunio , I.A.,Junejo , A., 2017.Impact of Auxiliary Equipments' Consumption on Electricity Generation Cost in Selected Power Plants of Pakistan”, 36 419 -434
Satish , V.,Raju, 2016.Energy and Exergy Analysis of Thermal Power Plant”,International Journal of Engineering Science and Computing 6 2636 -2644
Ahmadi , G.R.,Toghraie , D., 2016.Energy and Exergy Analysis of Montazeri Steam Power Plant in Iran”, Renewable and Sustainable Energy Reviews, 56 454 -463
ZareV.,Hasanzadeh , M., 2016.Energy and Exergy Analysis of a Closed Brayton Cycle-Based Combined Cycle for Solar Power Tower Plants”,Energy Conversion and Management 128 227 -237
Kotas , T.J., 1995.The Exergy Method of Thermal Plant Analysis”, -
Wu , L.,Wang , L.,Wang , Y.,Hu , X.,Dong , C.,Yanga , Z.,Yang , Y.,EnergyProcedia, 2014.Component and Process Based Exergy Evaluation of a 600MW Coal-Fired Power Plant”, 61 2097 -2100
Rosen M.A., and Dincer, I., “Exergy as the Confluence of Energy, Environment and Sustainable Development”, Exergy, An International Journal, Volume 1, pp. 3-13, 2001.
Amir, V., “Improving Steam Power Plant Efficiency Through Exergy Analysis: Ambient Temperature”, Proceeding of 2nd International Conference on Mechanical, Production and Automobile Engineering, pp. 28-29, Singapore, 2012
Ameri, M., Ahmadi, P., and Hamidi, A., “Energy, Exergy and Exergoeconomic Analysis of a Steam Power Plant: A Case Study”, International Journal of Energy Research, Volume 33, pp. 499-512, 2009
Regulagadda, P., Dincer, I., and Naterer, G.F., “Exergy Analysis of a Thermal Power Plant with Measured Boiler and Turbine Losses”, Applied Thermal Engineering, Volume 30, pp. 970-976, 2010
Memon, A.G.,Memon, R.A., Harijan, K., and Uqaili, M.A., “Parametric Based Thermo-Environmental and ExergoeconomicAnalyses of a Combined Cycle Power Plant with Regression Analysis and Optimization”, Energy Conversion and Management, Volume 92, pp. 19-35, 2015.
Rajper, M.A., Memon, A.G., and Harijan,K., “Exergy Analysis of a Subcritical Reheat Steam Power Plant with Regression Modeling and Optimization”, Mehran University Research Journal of Engineering & Technology, Volume 35, No. 3, pp. 459-472, Jamshoro, Pakistan, July, 2016
Erdem, H.H., Akkaya, A.V., Cetin, B., Dagdas, A., Sevilgen, S.H., Sahin, B., Take, I., Gungor, C., and Atas, S., “Comparative Energetic and Exergetic Performance Analyses for Coal-Fired Thermal Power Plants in Turkey”, International Journal of Thermal Sciences, Volume 48, pp. 2179-2186, 2009
Cihann, A., Lu, O.H., and Kahveci, K., “Energy–Exergy Analysis and Modernization Suggestions for a Combined- Cycle Power Plant”, International Journal of Energy Research, Volume 30, pp. 115-126, 2006
Ameri, M., Ahmadi, P., and Khanmohammadi, S., “Exergy Analysis of a 420MW Combined Cycle Power Plant”, International Journal of Energy Research, Volume 32, pp. 175-183, 2008
Memon, A.G., Harijan, K., Shah, S.F., Memon, R., and Uqaili M.A., “Exergy Analysis of 144 MW Combined Cycle Power Plant Kotri Pakistan”, Sindh University Research Journal, (Science Series) Volume 45, pp. 107-112, Jamshoro, Pakistan, 2013
Woudstra, N., Woudstra, T., Pirone, T., and Stelt, T.V.D., “Thermodynamic Evaluation of Combined Cycle Plants”, Energy Conversion and Management, Volume 51, pp. 1099-1110, 2010.
Rosen, M.A., Dincer, I., and Kanoglu, M., “Role of Exergy in Increasing Efficiency and Sustainability and Reducing Environmental Impact”, Energy Policy, Volume 36, pp. 128-137, 2008.
Aljundi, I.H., “Energy and Exergy Analysis of a Steam Power Plant in Jordan”, Applied Thermal Engineering, Volume 29, pp. 324-328, 2009
Dincer, I., “The Role of Exergy in Energy Policy Making”, Energy Policy, Volume 30, pp. 137-149, 2002
Roosen, P., Uhlenbruck, S., and Lucas, K., “Pareto Optimization of a Combined Cycle Power System as a Decision Support Tool for Trading Off Investment vs. Operating Costs”, International Journal of Thermal Sciences, Volume 42, pp. 553-560, 2003
http:/ /www.wisconsinpublicser vice.com/company/ history.aspx [Assessed Date: 05.04.2017
El-Wakil, M.M., “Power Plant Technology”, McGraw- Hill, 1984
Rajper, M.A., Memon, A.G., and Harijan, K., “Energy and Exergy Analysis of 210 MW Jamshoro Thermal Power Plant”, Mehran University Research Journal of Engineering & Technology, Volume 35, No. 2, pp. 265-274, Jamshoro, Pakistan, April, 2016