No Detail Found!

Seismic response evalution of base isolated buildings

Author(s)
A. Hameed Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan
M. Saleem Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan
A. U. Qazi Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan
H. Rizwana Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan
Abstract
The main purpose of seismic isolation is to protect the structures against damage from earthquake by reducing the forces transferred to the structure rather than resisting them. Non linear dynamic analysis is carried out for buildings with and without base isolation. The non linearity is confined at base isolator and superstructure is kept in linear elastic state. Lead rubber bearing is used as base isolator for the study. The presented research work is divided in three phases. Comparison of performance of fix base and base isolated building is done in phase-I. Phase-II explains the effect of height and number of bays in base isolated buildings. In phase-III, the response of building is evaluated by varying the properties of base isolator i.e. time period and effective damping. The results of phase-I revealed that seismic isolation of a fix base building reduces the floor accelerations and base shear by lengthening the natural period of vibration of the structure. Inter storey drifts are also reduced as hysteretic damping is provided by lead core of lead rubber bearing. Relative displacements are increased at each storey level due to lateral flexibility provided by lead rubber bearing. Phase-II revealed that seismic isolation is more effective within the range of 8 to 10 storey for moment resisting frame structures. Increase in number of bays is not proved to be effective as the floor accelerations, displacements and storey drifts remains almost constant for base isolated buildings. From phase-III, it was realized that by increasing the time period of base isolator, natural time period of vibration of building is also increased. This increase in natural time period reduces the floor accelerations and base shear. By increasing the time period of base isolator, the displacement at each storey level is also increased. On the other hand by increasing the effective damping of base isolators floor acceleration, base shear, displacements and inter storey drifts all are reduced.
Publication Details
Page(s) 46-54
DOI DOI not available
Published Journal: Pakistan Journal of Science, Volume: 65, Issue: 1, Year: 2013

Request the full text from PASTIC

0

Citations

0

Downloads

40

Views