Aerospace structures are thin-walled structures which make them susceptible to instability failure. Thin flat sheet is inefficient in carrying compressive loads because its buckling stress is relatively low. This weakness, however, can greatly be improved by attaching stiffeners along the length of the plate using rivets that are spaced at a certain pitch. Stinger stiffend compression panels have been used extensively in aeronautical structures. There are many design variables that affect the collapse behaviour of stiffened panels. This paper carries a parametric study to investigate the effect of five variables on the load carrying capacity of stiffened compression panels. These variables are: rivet pitch, stiffener pitch, flange width, panel length and type of stiffener. Four different buckling modes are considered. These are: overall buckling, local buckling, inter-rivet buckling and wrinkling. Experiments were also carried out on thin-walled stiffened panels, and the experimental results were used to verify the predicted results.