Abstract
Open pipe outlets used in irrigation systems in Pakistan are mainly designed under free-orifice and submerged-orifice-flow conditions, using a single discharge equation and an average coefficient of discharge value. The field calibrations data on 21 open pipe outlets along the Warsak Gravity Canal in the N. W. F. P. of Pakistan have been used to evaluate the effect of coefficient of discharge on flow rate. The results indicate a variation in Cd of -±- 50 % from the design value.
Publication Details
Page(s) 75-82
DOI DOI not available
Published Journal: Journal of Engineering and Applied Sciences, Volume: 12, Issue: 1, Year: 1993