The previously reported data on the variation of electrical conductance with applied voltage and absorbed water in some intervals are analysed more fully and the following approximate relationship is proposed for samples of Jutoid, a jute-based bituminous composition. log?/?°=0.045 (CF + 0.02 F2). 0.5 x C; where C is the weight % of water and F is the applied field in Kilovolts/cm.