No Detail Found!

Design proposal for load transfer mechanism of column-slab joints.

Author(s)
Abid Ali Shah National Institute of Transportation, National University of Sciences & Technology, Risalpur, Pakistan
Shaukat Ali Khan National Institute of Transportation, National University of Sciences & Technology, Risalpur, Pakistan
Amjad Naseer Department of Civil Engineering, NWFP University of Engineering and Technology, Peshawar, Pakistan
Abstract
The current research describes the test results of eight RC columns with properly modeled confinement conditions. The experimental program was carried out to investigate the effects of normal strength concrete (NSC) slab layer on high strength concrete (HSC) columns. The specimens consisted of six interior columns, one sandwich column, and one isolated column made completely of HSC. Interior and sandwich column specimens have a 120-240 mm NSC slab layers at mid height while the isolated column specimen had no such layer. The available test data was analyzed to find the appropriate/actors affecting the joint strength behaviour. The effects of slab load intensity, joint aspect ratio, slab reinforcement ratio, and surrounding slab confinement on the strength and ductility of the column-slab joints were profoundly investigated.
Publication Details
Page(s) 83-94
DOI DOI not available
Published Journal: Journal of Engineering and Applied Sciences, Volume: 25, Issue: 1, Year: 2006

Request the full text from PASTIC

0

Citations

0

Downloads

54

Views