No Detail Found!

Grid-connected converters active power flow control under unbalanced conditions by fuzzy technique

Author(s)
Shaik Hussain Vali Department of Electrical and Electronics Engineering, JNTUA College of Engineering Pulivendula,Kadapa,India
Vempalle Rafi Department of Electrical and Electronics Engineering, JNTUA College of Engineering Pulivendula,Kadapa,India
K. Ravisankar Department of Electrical and Electronics Engineering, JNTUA College of Engineering Pulivendula,Kadapa,India
Sadhu Radha Krishna Department of Computer Science Engineering, JNTUA College of Engineering Pulivendula,Kadapa,India
Pradyumna Kumar Dhal Department of Electrical and Electronics Engineering,Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology,Chennai,India
R. Narendra Rao Department of Electrical and Electronics Engineering, JNTUA College of Engineering Pulivendula,Kadapa,India
Abstract
The SVPWM technique is being used in this research for active power flow control in grid-connected converters working in an unbalanced environment. This study proposes an improved VSS in converter-interfaced devices, nicknamed zero-sequence compensated voltage support, to dependably maintain the three-phase voltages at the connection point within the pre-set safety limits (ZCVS). In its compensation, the proposed technique takes into consideration both the zerosequence component and the active power injection. Unlike traditional techniques, the proposed VSS can be employed in resistive distribution systems. Nonetheless, this work only provides a minimal contribution. The second contribution proposes combining the zero-capacitance voltage source with the limited active power oscillation (LAPo) (ZCVS). sustaining the alternating current host grid in the face of highly unbalanced faults while reducing oscillation(LAPo) to the voltage source with zero capacitance (ZCVS). This capability allows the AC host grid to be supported in the face of severely unbalanced faults while restricting oscillation to a user-specified value. Finally, a formula for the maximum active power delivery (MAPD) of the ZCVS to the alternating current grid has been created. Using the fuzzy method and complementary approaches, chosen simulation test scenarios are employed to assess the successful outcomes of the proposed support system.
Publication Details
Page(s) 1683-1691
DOI DOI not available
Published Journal: ARPN Journal of Engineering and Applied Sciences, Volume: 20, Issue: 19, Year: 2025

Request the full text from PASTIC

Keywords
Active power oscillations, maximum power delivery, fault ride through, unbalanced voltages, positive and negative sequence control, dc voltage ripples, reactive current injection
References
Hossain M. K.,Ali M. H. .2015 .Transient stability augmentation of PV/DFIG/SG-based hybrid power system by nonlinear control-based variable resistive FCL. IEEE Trans. Sustain. Energy, 6(4) : 1638-1649.
Xiao H.,Luo A.,Shuai Z.,Huang Y. .2016 .An improved control method for multiple bidirectional power converters in a hybrid AC/DC microgrid. IEEE Trans. Smart Grid, 7(1) : 340-347.
Wang P.,Jin C.,Zhu D.,Tang Y.,Loh P. C.,Choo F. H. .2015 .Distributed control for autonomous operation of a three-port AC/DC/DS hybrid microgrid. IEEE Trans. Ind. Electron, 62(2) : 1279-1290.
Alobeidli K. A.,Syed M.,Moursi M. E.,Zeineldin H. .2015 .Novel coordinated voltage control for a hybrid micro-grid with islanding capability. IEEE Trans. Smart Grid, 6(3) : 1116-1127.
Camacho A.,Castilla M.,Miret J.,Guzmán Y A. Borrell R. .2014 .Reactive power control for distributed generation power plants to comply with voltage limits during grid faults. IEEE Trans. Power Electron, 29(11) : 6224-6234.
Chaudhary S.,Teodorescu R.,Rodriguez P.,Kjaer P. C.,Gole A. M. .2012 .Negative sequence current control in wind power plants with VSCHVDC connection. IEEE Trans. Sustain. Energy, 3(3) : 535-544.
Mohamed Y.,El-Saadany E. .2008 .A control scheme for PWM voltage source 3 distributed generation inverters for fast load-voltage regulation and effective mitigation of unbalanced voltage disturbances. IEEE Trans. Ind. Electron, 55(5) : 2072-2084.
Howlader A. M.,Senjyu T. .2016 .A comprehensive review of low voltage ride through capability strategies for the wind energy conversion systems. Renew. Sustain. Energy Rev, 56 : 643-658.
Mohammadalizadeh-Shabestaryet al M. .2015 .A general approach for optimal allocation of FACTS devices using equivalent impedance models of VSCs. Int. Trans. Electr. Energy Syst, 25 : 1187-1203.
H. H .2013 .A new method based on sensitivity analysis to optimize the placement of SSSCs. J. Electr. Eng. Comput. Sci, 21(1) : 1956-1971.
Rafi V.,Dhal P. K.,Rajesh M.,Srinivasan D. R.,Chandrashekhar M.,and Reddy N.M. M. .2023 .Optimal placement of time-varying distributed generators by using crow search and black widow-Hybrid optimization. Measurement: Sensors. 30, : 100900.
Ramyar A.,Iman-Eini H A.,Farhangi S. .2016 .Global maximum power point tracking method for photovoltaic arrays under partial shading conditions. IEEE Transactions on Industrial Electronics, 64(4) : 2855-2864.
Vempalle R.,Pradyumna Kumar D. R. .2025 .An intelligent optimization technique for performance improvement in a radial distribution network. International Journal of Intelligent Unmanned Systems, 13(1) : 38-53.
0

Citations

0

Downloads

27

Views