No Detail Found!

Experimental investigation of overall energy performance in Algerian office building integrated photovoltaic window under semi-arid climate

Author(s)
Mesloub Abdelhakim Faculty of Built Environment and Surveying,Universiti Teknologi Malaysia (UTM), Johor,Malaysia
Mohd Zin Kandar Faculty of Built Environment and Surveying,Universiti Teknologi Malaysia (UTM), Johor,Malaysia
Yaik-Wah Lim Centre for the Study of Built Environment in the Malay World (KALAM), Institute for Smart Infrastructures and Innovative Construction, UTM,Johor,Malaysia
Abstract
Building integrated photovoltaic (BIPV) energy has now become one of the most significant renewable energy alternatives for providing natural daylight and clean energy. As such, this study was conducted for the first time in Algeria to experimentally evaluate the BIPV window energy and lighting energy savings of a typical office building under the semi-arid climate condition. Apart from using the Energy Plus and Integrated Environment Solution-Virtual environment (IES-VE) energy simulation tools in the experimental validation, the daylighting control method and the dynamic Useful Daylight Illuminance (UDI) were also utilized to analyse the daylighting performance as well as the lighting energy of BIPV windows with different transparency levels at various cardinal orientations. The field measurements had revealed the overall energy model to be consistent and in good agreement with the EnergyPlus and the IESVE simulation models, where the tested PV module was found to have provided not only a 20% Visible Light Transmittance (VLT) of uniformed daylight with low illuminance level, but also thermal comfort and a considerable amount of clean energy. The simulated results had demonstrated a substantial improvement in cooling energy and glare reduction of the PV modules as compared to the basemodel, where the only BIPV window configuration was achieved good area of UDI 300-700 lux is facing the South orientation and 30% VLT. In conclusion, the application of the thin film BIPV windows with different transparency and orientation levels can thus be regarded as an effective solution for minimizing the lighting energy consumption through its energy production instead of daylighting utilization.
Publication Details
Page(s) 23-41
Published Journal: Journal of Daylighting, Volume: 6, Issue: 1, Year: 2019

Request the full text from PASTIC

Keywords
BIPV window, Overall energy, Simulation, Daylight
References
Hao G.,Yu X.,Huang Y.,Xu Y.,Zhao X.,Li H.,Chen M. .2007 .Application and Development of Building-Integrated Photovoltaics(BIPV) System in China. in: Proceedings of ISES World Congress, : 1685-1689.
Amirat M.,El S.,Hassar S. .2005 .Economies d'energie dans le secteur de l'habitat consommation electrique des ménages: Cas d'un foyer algérien typique en période d'hiver, Revue des énergies renouvelables 8 (. , : 27-37.
Abdelhakim M.,Jibril J.D.,Kandar M. Z. .2017 .Low Carbon Emission through the Use of BIPV Windows in Algerian Mid-Rise Buildings. Chemical Engineering Transactions, 56 : 541-546.
Stambouli A. B.,Khiat Z.,Flazi S.,Kitamura Y. .2012 .A review on the renewable energy development in Algeria: Current perspective, energy scenario and sustainability issues. Renewable and Sustainable Energy Reviews, 16 : 4445-4460.
Heinstein P.,Ballif C.,-E. C.,ENERGYO C. .2018 .Building Integrated Photovoltaics (BIPV): Review, Potentials, Barriers and Myths. , : .
Kalogirou S. A. .2013 .Building integration of solar renewable energy systems towards zero or nearly zero energy buildings. International Journal of LowCarbon Technologies, 10 : 379-385.
Monetti V.,Davin E.,André P.,Filippi M. .2015 .. Calibration of Building Energy Simulation Models Based on Optimization: A Case Study, Energy Procedia, 78 : 2971-2976.
Nikpour M.,Kandar M.,Roshan M. .2013 .Empirical vof IES< VE> simulation in term of daylight in self-shading office room in Malaysia. Journal of Basic Applied Science Research, 3 : 106-112.
Crawley D. B.,Pedersen C. O.,Lawrie L.,Winkelmann F. C. .2000 .Energy Simulation Program. ASHRAE journal 42, : 49-56.
Abdelhakim M.,Lim Y.-W.,M. Y.-W. .2019 .Zin Kandar, Optimum Glazing Configurations for Visual Performance in Algerian Classrooms under Mediterranean Climate. Journal of Daylighting, 6 : 11-22.
Hachem C.,Fazio P.,Athienitis A. .2013 .Solar optimized residential neighborhoods: Evaluation and design methodology. Solar Energy, 95 : 42-64.
Wright J. A.,Brownlee A.,M. M. Mourshed M.,Wang M. . ., Multi-objective optimization of cellular fenestration by an evolutionary algorithm. Journal of Building Performance Simulation, 7(2013) : 33-51.
Kapsis K.,Dermardiros V.,Athienitis A. K. .2015 .Daylight Performance of Perimeter Office Façades utilizing Semi-transparent Photovoltaic Windows: A Simulation Study. Energy Procedia, 78 : 334-339.
Moscoso C. P. .2016 .. Daylighting and Architectural Quality: Aesthetic Perception of Daylit Indoor Environments, : .
Hensen J.L.,Lamberts R. .2012 .Building performance simulation for design and operation,. , : .
K.-W. Park A. K.,Athienitis A. K. .2003 .Workplane illuminance prediction method for daylighting control systems. Solar Energy, 75 : 277-284.
Andersen D.,Foldbjerg R.,Climate-Basic Book Indoor .2012 .Editorial team: Daylight Energy and Indoor Climate (DEIC), VELUX A/S,. , : .
J.-H. Song Y.-S.,An S.-J.,Lee J.-H.,Yoon J.-H.,-K. Choung J.-H. .2008 .Power output analysis of transparent thin-film module in building integrated photovoltaic system (BIPV). Energy and Buildings, 40 : 2067-2075.
J.-H. Yoon S.-R.,Shim Y. S.,An K. H.,Lee K. H. .2013 .An experimental study on the annual surface temperature characteristics of amorphous silicon BIPV window. Energy and Buildings, 62 : 166-175.
Agathokleous S.,Kalogirou S. .2018 .Simulation-Based Investigation of the Air Velocity in a Naturally Ventilated BIPV System. , : .
Wang M.,Peng J.,Li N.,Yang H.,Wang C.,Li X.,Lu T. .2017 .Comparison of energy performance between PV double skin facades and PV insulating glass units. Applied Energy, 194 : 148-160.
Zhang W.,Peng J.,Song A. .2016 .Comparison of the overall energy performance of semi-transparent photovoltaic windows and common energyefficient windows in Hong Kong. Energy and Buildings, 128 : 511-518.
Sun Y.,Shanks K.,Baig H.,Zhang W.,Hao X.,Li Y.,He B.,Sundaram S.,Zhang J.,Mallick T.,Wu Y. .2018 .Integrated semitransparent cadmium telluride photovoltaic glazing into windows: Energy and daylight performance for different architecture designs. Applied Energy, 231 : 972-984.
Huang Q. .2014 .Study on thermal and daylighting performance of a double-glazed PV ventilated window in cold areas. , : .
Simson R.,Kurnitski J.,Kuusk K. .2017 .Experimental validation of simulation and measurement-based overheating assessment approaches for residential buildings. Architectural Science Review, 60 : 192-204.
Djalel D. .2014 .Optimal Exploitation of a Solar Power System for a Semi-Arid Zone (Case Study: Ferkène. International Journal Of Renewable Energy Research, 4 : 389-400.
Djamel Z.,Noureddine Z. .2017 .The Impact of Window Configuration on the Overall Building Energy Consumption under Specific Climate Conditions. Energy Procedia, 115 : 162-172.
Hajibabaei M. .2014 .Comparison of Different Methods of Measuring Illuminance in the Indoor of Office and Educational Buildings. Jundishapur Journal of Health Sciences 6, : .
Carlucci S.,Causone F.,De Rosa F.,Pagliano L. .2015 .A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design. Renewable and Sustainable Energy Reviews, 47 : 1016-1033.
Luo Y.,Feng Z.,Li H. .2010 .Design of compact and smooth free-form optical system with uniform illuminance for LED source. Optics Express, 18 : 9055.
C.-M. Chiang ,C.-M. Lai .2002 .A study on the comprehensive indicator of indoor environment assessment for occupants' health in Taiwan. Building and Environment, 37 : 387-392.
Yadav D. P. .2017 .Energy Saving Assessment for Building Envelope of Supermarket Based on EnergyPlus and Openstudio. American Journal of Civil Engineering, 5 : 141.
Chen F.,Wittkopf S. K.,Khai Ng P.,Du H. .2012 .Solar heat gain coefficient measurement of semi-transparent photovoltaic modules with indoor calorimetric hot box and solar simulator. Energy and Buildings, 53 : 74-84.
Wah W. P.,Shimoda Y.,Nonaka M.,Inoue M.,Mizuno M. .2005 .Modeling of Semi-Transparent PV in Power, Thermal and Optical Aspects. Journal of Asian Architecture and Building Engineering, 4 : 549-556.
Barman S.,Chowdhury A.,Mathur S.,Mathur J. .2018 .Assessment of the efficiency of window integrated CdTe based semi-transparent photovoltaic module. Sustainable Cities and Society, 37 : 250-262.
Ghani S.,Bialy E. M.,Bakochristou F.,Gamaledin S. M. A.,M. M. Rashwan B.,Hughes B. .2017 .Thermal comfort investigation of an outdoor air-conditioned area in a hot and arid environment. Science and Technology for the Built Environment, 23 : 1113-1131.
Mounira Badeche Y.B. .2018 .Energy Demand Reduction Applying Different Window sizes for an office building in semi-arid climate. Journal of Buildings and Sustainability, 1 : 1-10.
Remund J.,Müller S.C. .2011 .Solar radiation and uncertainty information of Meteonorm 7. in: Proceedings of 26th European Photovoltaic Solar Energy Conference and Exhibition, : 4388-4390.
Pidwirny M. .2014 .Single chapter from the eBook Understanding Physical Geography. , : .
Xue G.,Liu K.,Chen Q.,Yang P.,Li J.,Ding T.,Duan J.,Qi B.,Zhou J. .2017 .Robust and Low-Cost Flame-Treated Wood for High-Performance Solar Steam Generation. ACS Applied Materials & Interfaces, 9 : 15052-15057.
0

Citations

0

Downloads

11

Views