No Detail Found!

Daylighting metrics: an approach to dynamic cubic illuminance

Author(s)
Juan Manuel Monteoliva Instituto de Ambiente, Hábitat y Energia (INAHE), CONICET, Ruiz Leal N/N Avenue (CP5500),Mendoza,Argentina
Ayelén Villalba Instituto de Ambiente, Hábitat y Energia (INAHE), CONICET, Ruiz Leal N/N Avenue (CP5500),Mendoza,Argentina
Andrea Pattini Instituto de Ambiente, Hábitat y Energia (INAHE), CONICET, Ruiz Leal N/N Avenue (CP5500),Mendoza,Argentina
Abstract
Advances in research work in the field of numerical analysis of daylight performance have generated in-depth knowledge on photometric measurements of daylight quality. Most dynamic metrics are based on illuminance, which is a two-dimensional concept insofar as it is concerned with the density of luminous flux incident at a point on a surface. In order to extend dynamic metrics into the third dimension and consider the distribution of illumination at a point in space, it is important to generate new advances in simulation environments and consider spatial illumination metrics. In this context, the main objective of the present work was to advance in the development of cubic dynamic daylight metrics, as a complement to the two dimensional analysis currently employed, promoting the use of Climate Based Daylight Modelling (CBDM). For this purpose, cylindrical to horizontal illuminance ratio is applied to dynamic simulation paradigm developing the concept of useful modeling indexs (UMIs). The research methodology applied in this work is divided into two main parts: (i) two dimensional concept: spatial daylight autonomy (sDA(300lx,50%) -horizontal-, sDA(175lx,50%) -vertical-) and uniformity, and (ii) three dimensional concept: useful cylindrical to horizontal illuminance ratio (uEcl/Eh(0.3-0.6)). In order to assess this method, two spaces (RR1 and RR2) of the Lavalle Public Library, located in Mendoza-Argentina, were taken as a case study. Results show important differences in horizontal illuminance between RR1 and RR2 (?sDA(300lx, 50%) > 80%). Similar values of uEcl/Ewp(0.3-0.6) -useful cylindrical to horizontal illuminance ratio- are detected in both rooms (RR1= 69.32 % and RR2= 72.24 %) in nodes near north opening. Yet there are significant differences (< 36%) of uEcl/Ewp(0.3-0.6) between nodes located near the south wall, this is due to the obstruction of a south opening in RR2. Furthermore, it is important to mention that 2D metrics display a more uniform behavior than 3D metrics. This shows itself clearly if we take into account that difference in sDA are much lower than difference in uEcl/Eh(0.3-0.6), if we compare nodes closest to the north windows to does that are far from it, in both rooms (RR1 and RR2). This results from the fact that cubic metrics are more sensitive to the direction of light. This is of crucial importance for daylight studies in clear sky condition, due to the defined direction of direct solar radiation. Finally, a new approach to daylighting performance analysis based on the addition of cubic metrics to dynamic daylight paradigm is proposed: useful modelling indexs (UMIs). UMIs make it possible to quantify annual occurrence of proper light modelling conditions. As an initial approach, cylindrical to horizontal illuminance ratio (Ecl/Ewp(0.3-0.6)) has been considered, due to its current use in international standards.
Publication Details
Page(s) 34-42
Published Journal: Journal of Daylighting, Volume: 5, Issue: 2, Year: 2018

Request the full text from PASTIC

Keywords
Daylight, Cubic illuminance, Dynamic simulation, Daylighting metrics
References
Boyce P. .2013 .Lighting quality for all. in: CISBE SLL Int. Light. Conf., : 1-5.
Veitch J. A.,Newsham G. R. .1998 .Determinants of Lighting Quality I: State of the Science. Journal of the Illuminating Engineering Society, 27 : 92-106.
Kruisselbrink T.,Dangol R.,Rosemann A. .2018 .Photometric measurements of lighting quality: An overview. Building and Environment, 138 : 42-52.
Goodman T. M. .2009 .Measurement and specification of lighting: a look at the future. Light. Res. Technol, 41 : 229-243.
Christophe M.,Fontoynont M.,Christoffersen J.,Dubois M.C.,Wienold J.,Osterhaus W. .2003 .User Assessment of Visual Comfort: Review of Existing Methods'. Ingélux (France) with Danish Building Research Institute (SBi, Denmark) and Fraunhofer Institute for Solar Energy Systems. , : .
Wienold J.,Christoffersen J. .2006 .Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras. Energy and Buildings, 38 : 743-757.
Lucas R.J.,Peirson S.N.,Berson D.M.,T.M. Brown H.M.,Cooper C.A.,Czeisler M.G.,Figueiro P.D.,Gamlin S.W.,Lockley S.W.,J.B. O'Hagan L.L.A.,Price I.,Provencio D.J.,Skene G.C.,Brainard G.C. .2014 .Measuring and using light in the melanopsin age. Trends Neurosci, 37 : 1-9.
I. Ashdown .1998 .The virtual Photometer: modeling the flow of light. IESNA 1998 Annu. Conf. Tech. Pap, : .
Cuttle C. .1997 .. Lighting Research and Technology, 29(1) : 1-14.
W.J.M. van Bommel G.J. van den Beld .2004 .Lighting for work: a review of visual and biological effects. Lighting Research and Technology, 36 : 255-269.
Tregenza P.R.,Waters I.M. .1983 .. Lighting Research and Technology, 15 : 65-71.
Mardaljevic J.,Heschong L.,Lee E. .2009 .Daylight metrics and energy savings. Lighting Research and Technology, 41 : 261-283.
Reinhart C.F.,J. Wienold, C.F. .2011 .The daylighting dashboard a simulation-based design analysis for daylit spaces. Building and Environment, 46 : 386-396.
Andersen M.,Kleindienst S.,Yi L.,Lee J.,Bodart M.,Cutler B. .2008 .Informing daylighting design with the Lightsove approach: Why and. Conference on Passive and Low Energy Architecture, : .
Perez R.,Seals R.,Michalsky J. .1993 .All-weather model for sky luminance distribution - Preliminary configuration and validation. Solar Energy, 50 : 235-245.
Reinhart C.,Mardaljevic J.,Rogers Z. .2006 .Dynamic daylight performance metrics for sustainable building design. Leukos, 3 : 7-31.
Costanzo V.,Evola G.,Marletta L.,Pistone F.,Nascone F. .2018 .Application of Climate Based Daylight Modelling to the Refurbishment of a School Building in Sicily. Sustainability, 10 : 2653.
Monteoliva J.,Villalba A.,Pattini A. .2015 .Variability in dynamic daylight simulation in clear sky conditions according to selected weather file: Satellite data and land-based station data. Lighting Research & Technology, 49 : 508-520.
Nabil A.,Mardaljevic J. .2006 .Useful daylight illuminances: A replacement for daylight factors. Energy and Buildings, 38 : 905-913.
J.M. Monteoliva A.,Villalba A.,Pattini A. .2014 .control solar en aulas. Impacto en la simulación dinámica de la iluminación natural. Ambiente Construido, 14 : 43-58.
.2012 .IES Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE). , 83 : 12.
Bellia L.,Fragliasso F.,Pedace A. .2015 .Evaluation of Daylight Availability for Energy Savings. Journal of Daylighting, 2 : 12-20.
Cuttle C. .2013 .A practical approach to cubic illuminance measurement. Lighting Research & Technology, 46 : 31-34.
Cuttle C. .2008 .Lighting by Design. 2nd edition, : .
Córica L.,Lagsano C.,Colombo E.,Pattini A. .2015 .Análisis y caracterización fotométrica de un espacio de transición iluminado con luz natural: sus implicancias en la visión funcional. Ambiente Construído, 15 : 103-115.
Standards British,Work Indoor,Places Indoor .2011 .Institution. BS EN 12464-1: 2011. Light and Lighting - Lighting of Work Places - Part, 1 : .
Hewitt H.,Bridgers D.J.,Simons R.H. .1965 .Lighting and the environment. Trans. Illum. Eng. Soc, 30 : 91.
Bean A.R. .1978 .Modelling indicators for combined side and overhead lighting systems. Lighting Research and Technology, 10 : 199-202.
Love J. A.,Navvab M. .1994 .The Vertical-to-Horizontal Illuminance Ratio: A New Indicator of Daylighting Performance. Journal of the Illuminating Engineering Society, 23 : 50-61.
Gershun A. .1936 .The light field. J. Math. Phys. 18, : 51-151.
Howlett O.,Heschong L.,Mchugh J. .2007 .Scoping study for daylight metrics from luminance maps scoping study for daylight metrics from luminance maps. Leukos, 3 : 201-215.
Ruiz Veronica,Jimena Veronica .2017 .Iluminación sustentable. Mendoza (Argentina), : .
Molina G.,Vera S.,Bustamante W.,Bleicher T. .2008 .. , : .
Ward G.,Rubinstein F. .1988 .A new technique for computer simulation of illuminated spaces. Lawrence Berkeley Laboratory Report 23042, : .
Ward G. .1994 .. Computer Graphics, in: Proceedings of '94 SIGGRAPH Conference, : .
Berardi U.,Wang T. .2014 .Daylighting in an atrium-type high performance house. Building and Environment, 76 : 92-104.
J.A. Jakubiec C.F. Reinhart .2012 .- A concept for assessing glare throughout daylit spaces. Lighting Research and Technology, 44 : 149-170.
Work Indoor,Places Indoor .2011 .Guide to British Standards Institution. BS EN 12464-1: 2011. Light and Lighting - Lighting of Work Places - Part, 1 : .
Cuttle C. .2014 .A practical approach to cubic illuminance measurement. Lighting Research and Technology, 46 : 31-34.
Commission On Illumination International .1992 .Guide to the Lighting of Urban Areas. Technical Report., : .
Villalba A.,Monteoliva J.M.,A. Pattini J.M. .2016 .A dynamic performance analysis of passive sunlight control strategies in a neonatal intensive care unit. Lighting Research and Technology, 50 : 191-204.
J.M. Monteoliva A.,Villalba A.,Aceña A.,Pattini A. .2016 .Modelo Simplificado para el cálculo de iluminancia por luz natural útil (UDI) en espacios individuales perimetrales en cielos claros. Hábitat Sustentable, 6 : 51-59.
0

Citations

0

Downloads

12

Views