No Detail Found!

Microleakage Assessment of Flowable Composites and Hydrophilic Sealant: A Stereo Microscopic Study

Author(s)
Hooriyah Laiq Ahmed Khan Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai, 600077, India
Jayashri Prabakar Department of Public Health Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical sciences (SIMATS), Saveetha University, Chennai, 600077, India
Ganesh Jeevanandan Department of Pedodontics and Preventive Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical sciences (SIMATS), Saveetha University, Chennai, 600077, India
Rajeshkumar Shanmugam Nanobiomedicine Lab, Centre for Global Health Research, Saveetha Medical College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 602105, TN, India
Abstract
Objectives: Dental cavities are a prevalent issue that, if untreated, can escalate into severe complications. Minimally invasive treatments, such as fissure sealants, have been developed to prevent early-stage cavities from progressing. Traditional sealants, however, often fail due to moisture contamination during application. To address this, hydrophilic sealants were designed to perform effectively in moist environments. A critical determinant of their success is the ability to create a durable, tight seal along the edges. Methods: This study used 20 extracted, caries-free, sound molars, randomly divided into two groups: Group I (hydrophilic sealants) and Group II (flowable composites). Tooth sectioning was performed mesiodistally using a lowspeed diamond cutting blade. The specimens were immersed in 1% methylene blue solution at room temperature for 24 hours to assess dye penetration and the microleakage was evaluated using a stereomicroscope following Ovrebo and Raadal guidelines (1990). Results: Hydrophilic sealants demonstrated superior performance in microleakage prevention, with a significantly higher number of samples scoring zero for dye penetration compared to flowable composites. Statistical analysis using the Mann-Whitney U test (p < 0.05) confirmed that Group I exhibited less dye penetration, highlighting the enhanced sealing ability of hydrophilic sealants. Conclusion: Hydrophilic sealants exhibit better sealing efficacy and reduced microleakage compared to flowable composites, particularly under moist conditions. Their superior penetration and adaptability make them a promising option for long-lasting dental restorations. Future research should focus on larger sample sizes, long-term clinical performance and optimizing application techniques for diverse clinical scenarios.
Publication Details
Page(s) 48-52
Published Journal: Journal of Pioneering Medical Sciences, Volume: 13, Issue: 7, Year: 2024

Request the full text from PASTIC

Keywords
Dental caries, Microleakage, Dental adhesives, Marginal Sealing, hydrophilic sealants, flowable composites, stereo microscopy
References
.2012 .Microleakage resistance of minimally invasive class I flowable composite restorations. ” Operative Dentistry, 37(3) : 11-298.
Ravindran ,Vignesh .2024 .Comparative evaluation of wear strength and compressive strength of two pit and fissure sealants with a nanofilled resin coating: An in vitro study. International Journal of Clinical Pediatric Dentistry, 10005 : 2726-35.
Abdelaziz M.,Alghamdi M.,Alqarni M.,Alharbi S. .2020 .Microleakage in restorative materials: An in vitro study using dye penetration. Journal of Clinical Dentistry, : .
Peumans M.,De Munck J.,Mine A.,Van Meerbeek B. .2015 .Marginal adaptation, microleakage, and clinical performance of direct composites. Dental Materials Journal, : .
Gwinnett A. J.,Yu S.,He L. H.,Shinya A. .2007 .Microleakage testing: Review of materials and methods. Journal of Dental Research, : .
Khera S.,Chan D. C.,Schweitzer D. M.,Chan D. M. .2016 .Evaluation of microleakage in flowable composites and traditional composites. Journal of Esthetic and Restorative Dentistry, : .
Alani A. H.,Toh C. G. .2009 .Evaluation of microleakage in glass ionomer and composite restorations. British Dental Journal, : .
Yap A. U.,Teoh S. H.,Wong M. L. Microleakage .2008 .and adaptation of resin-modified glass ionomer restorations. Journal of Oral Rehabilitation, : .
Bortolotto T.,Kamposiora P.,Garcia-Godoy F.,Krejci I. .2019 .A comparative analysis of microleakage in flowable composite restorations. Clinical Oral Investigations, : .
Bouillaguet S.,Berthet A.,Wataha J. C. .2014 .Marginal adaptation and microleakage of resin composites and GIC restorations. Dental Materials Journal, : .
Frankenberger R.,Garcia-Godoy F.,Kramer N. .2016 .Microleakage in conventional and self-etch glass ionomer cements. American Journal of Dentistry, : .
Hickel R.,Manhart J.,Garcia-Godoy F. .2011 .Microleakage of restorative materials: An overview. Journal of Dentistry, : .
Vishwanathaiah S,Maganur PC,Syed AA,Kakti A,Hussain Jaafari AH,Albar DH .2024 .Effectiveness of silver diamine fluoride (SDF) in arresting coronal dental caries in children and adolescents: a systematic review. J Clin Pediatr Dent, : .
Akshaya . .A. KNOWLEDGE, ATTITUDE AND PERCEPTION OF PIT AND FISSURE SEALANT ON DECAY-A SURVEY. 2022 Jul, 1(5) : .
Bramhecha A,Datta J,Balasubramaniam A . .What preventive strategies do dentists prescribe for dental caries prevention? - A KAP survey. 2023, : .
Kishen A,Veeraraghavan VP,Somasundram J,Gayathri R .2022 .Effect of pit-and-fissure sealants on postbrushing simulation - A photogenic study. J Adv Pharm Technol Res, : .
0

Citations

0

Downloads

40

Views