No Detail Found!

Confocal Assessment of Microleakage of Hydrophilic Sealants and Flowable Composites

Author(s)
Dev Arora Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai, 600077, India
Jayashri Prabakar Department of Public Health Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical sciences (SIMATS), Saveetha University, Chennai, 600077, India
Ganesh Jeevanandan Department of Pedodontics and Preventive Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical sciences (SIMATS), Saveetha University, Chennai, 600077, India
Rajeshkumar Shanmugam Nanobiomedicine Lab, Centre for Global Health Research, Saveetha Medical College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 602105, TN, India
Abstract
Objectives: Dental caries is a highly prevalent chronic condition that, if left untreated, can result in severe oral health consequences, including pain, infection and tooth loss. Micro-invasive treatments for dental caries, such as fissure sealants, are effective in arresting incipient caries in pits and fissures. However, conventional sealants face challenges such as technique sensitivity and failure under moisture contamination. Hydrophilic sealants were introduced to address these limitations, offering better adaptability in moist environments. Marginal sealing is a critical factor in determining the longevity and success of restorative treatments. Methods: The study utilized 20 extracted sound molar teeth free from caries and developmental defects. The samples were randomly divided into two groups of 10 each: Group I (Ultra-seal XT Hydro hydrophilic sealants) and Group II (Flowable composite). Mesiodistal sectioning was performed using a low-speed diamond cutting blade and the sections were immersed in 0.1% rhodamine B isothiocyanate dye at 37°C for 24 hours. Dye penetration was assessed using confocal laser scanning microscopy. Microleakage was evaluated following Ovrebo and Raadal guidelines (1990). Results: Group I (hydrophilic sealants) exhibited significantly less dye penetration compared to Group II (flowable composites), as determined by the Mann-Whitney U test (p = 0.041). The results indicated that hydrophilic sealants demonstrated superior marginal sealing, reducing microleakage more effectively than flowable composites. Conclusion: Hydrophilic sealants showed better performance in preventing microleakage than flowable composites, particularly in moistureprone conditions. These findings suggest that hydrophilic sealants are a valuable choice for enhancing the longevity and effectiveness of restorative treatments, with potential implications for improving clinical protocols and patient outcomes. Future research should explore the long-term durability, cost-effectiveness and real-world applications of these materials..
Publication Details
Page(s) 20-24
Published Journal: Journal of Pioneering Medical Sciences, Volume: 13, Issue: 7, Year: 2024

Request the full text from PASTIC

Keywords
Dental caries, Adhesive Dentistry, Microleakage, confocal microscopy, hydrophilic sealants, flowable composites
References
Vishwanathaiah ,Satish .2024 ."Effectiveness of silver diamine fluoride (SDF) in arresting coronal dental caries in children and adolescents: a systematic review. " Journal of Clinical Pediatric Dentistry, 101(5) : 27-40.
.2013 .. com/Caries-Management-Science-andClinical-Practice/9783131547118., 436 : .
Akshaya A,Deepak S. .2022 .“Knowledge, Attitude And Perception Of Pit And Fissure Sealant On Decay-A Survey. International Journal of Early Childhood Special Education, 14(5) : .
Beslot-Neveu ,May- . .Physico-chemical approach to pit and fissure sealant infiltration and spreading mechanisms. ” Pediatric Dentistry, 34(3) : 57-61.
dos Santos,Karina Tonini Santos,April 2008 . .Length of resin tags in pit-and-fissure sealants: all-in-one self-etching adhesive vs phosphoric acid etching.” Compendium of Continuing Education in Dentistry. , 29(3) : 186-192.
Duangthip D.,Observations SEM .2002 .Quality of Fissure Sealants Used by General Dental Practitioners: Microleakage. , : 80.
Eliacik Basak,Kiziltan Meltem,Karahan Meltem,November 2023 . .“Evaluating the effect of three fissure preparation techniques on microleakage of a colored flowable composite used as a fissure sealant. The Journal of Clinical Pediatric Dentistry, 47(6) : 119-129.
Övrebö Rosane,Costa Magne,Raadal Magne .1990 .Microleakage in fissures sealed with resin or glass ionomer cement. European Journal of Oral Sciences, 98(1) : 0722-69.
Spencer P. .1980 .In Vitro Comparison of a Hydrophilic and a Hydrophobic Fissure Sealant. , : 124.
Fontes F.G. .2000 .Comparison of the Microleakage of Self-etching Primers and a Conventional Bonding System Used in Conjunction with a Sealant: An in Vitro Study. oai% 3Aunion.ndltd.org%3AOCLC%2Foai%3Axtcat.oclc.org%3AOCLC No%2F606460780 and back=http%3A%2F%2Fsearch.ndltd.org% 2Fsearch.php%3Fq%3Dsubject%253A%2522sealants%2522, 260 : .
Zawam O.M. .2017 .The Effect of Pit and Fissure Morphology and Sealant Viscosity on Sealant Penetration and Microleakage. , : 166.
Duggal .1997 .The effect of different etching times on the retention of fissure sealants in second primary and first permanent molars. International Journal of Paediatric Dentistry, 7(2) : 1365-263x.
0

Citations

0

Downloads

45

Views