Combination T2 multiple echo data imaging and fast spin echo fat saturation technique to improve image quality on ankle magnetic resonance imaging

Author(s)
Akhmad Muzamil Faculty of Science and Technology, Airlangga University,Surabaya, Indonesia
Chendra Arum Wandani Department of Physics, Faculty of Science and Technology,Universitas Airlangga, Surabaya, Indonesia
Dita Aprilia Hariyani Department of Physics, Faculty of Science and Technology,Universitas Airlangga, Surabaya, Indonesia
Riries Rulaningtyas Department of Physics, Faculty of Science and Technology,Universitas Airlangga, Surabaya, Indonesia
Khusnul Ain Department of Physics, Faculty of Science and Technology,Universitas Airlangga, Surabaya, Indonesia
Perwira Annisa Dyah Permatasari Department of Mathematics, Faculty of Science and Technology, Airlangga University, Surabaya 60115, Indonesia
Suryani Dyah Astuti Department of Physics, Faculty of Science and Technology,Universitas Airlangga, Surabaya, Indonesia
Abstract
Objective: To determine the effect of the T2 Fast Spin Echo Fat Saturation (T2 FSE FAT SAT) sequence and T2 Multiple Echo Data Imaging Combination (T2 MEDIC) sequence on ankle images MRI. Methodology: The sequence variations were T2 FSE FAT SAT and T2 MEDIC. The effect of the sequence on the quality of the MRI ankle image was analyzed on the image of one patient and the sound intensity value through a sound level meter. Result: Data analysis was carried out quantitatively with the Region of Interest (ROI) method directly on the computer image of the MRI, then SNR (Signal to Noise Ratio) and CNR (Contras to Noise Ratio) analysis were carried out, and PSNR and MSE analysis was carried out through digital image processing to determine the value magnitudes. The highest SNR and CNR were found in the T2 MEDIC sequence. The lowest acoustic noise value is in the T2 MEDIC sequence. The differences in the physical mechanism of image formation are T2 FSE FAT SAT refocusing 180º RF and T2 MEDIC refocusing gradient fields. Conclusion:  Because the SNR and CNR on T2 MEDIC are higher and the value of the sound intensity level is low, it can be said that the sequence provides optimal results and low acoustic noise. 
Publication Details
Page(s) 639-642
DOI DOI not available
Published Journal: Rawal Medical Journal, Volume: 48, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
MRI, T2 Fast Spin Echo Fat Saturation (T2 FSE FAT SAT), T2 Multiple Echo Data Imaging Combination (MEDIC).
References
Aribal E,Asadov R,Ramazan A,Ugurlu M. Ü,Kaya H .2016 .Multiparametric breast MRI with 3T: Effectivity of combination of contrast enhanced MRI, DWI and 1H single voxel spectroscopy in differentiation of Breast tumors. Eur J Radiol, 85 : 979-986.
Zuhriyah A,Muzzamil A,Astuti SD .2020 .Determination the Ischemic Stroke of Brain MRI Based On Apparent Diffusion Coefficient (ADC) with b Value Variation. In Journal of Physics: Conference Series IOP Publishing, 1 : 012041.
Astuti SD,Astutik NVI,Muzamil A .2017 .Optimization of Bandwidth and Time Echo Parameters to Reduce Susceptibility Artifacts and Chemical Shift on MRI. J Postgrad Bioscie, 19 : 3-8.
Bradella MA,Tirman PF,Peterfy CG,Zarlingo M,Feller JF,Bost FW . .Accuracy of T2-Weighted Fast Spin Echo MR Imaging with Fat Saturation in Detecting Cartilage Defects in the Knee: Comparison with Arthroscopy in 130 Patients. , 172 : 1073-80.
Nata VAAP,Astuti SD,Wibowo RA .2021 .MRI Cervical Image Analysis with Fat Suppression Techniques Between Sequent Turbo Invers Recovery Magnitude (TIRM) and Fat Saturations (Fat Sat) on Degenerative Disc Diseaseat Haji Hospital Surabaya. Indonesian Appl Physics Letters, 2 : 22-26.
Muzamil A,Astuti SA,Fat Suppression Spectral Adiabatic Inversion S. .2021 .Recovery (SPAIR) to Optimize the Quality of MRI Pelvis Image. Malaysian J Med Health Sci, 17 : 74-77.
Caverly RH .2015 .MRI fundamentals: RF aspects of magnetic resonance imaging (MRI). IEEE Microwave Magazine, 16 : 20-33.
Mohan G,Subashini MM .2018 .MRI based medical image analysis: Survey on brain tumor grade classification. Biomed Signal Processing Control, 39 : 139-161.
Dale BM,Brown MA,Semelka RC .2015 .MRI: basic principles and applications. , : .
Del Grande F. Santini F,Herzka DA,Aro MR,Dean CW,Gold GE,Carrino JA .2014 .Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system. Radiographics, 34 : 217-233.
Muzamil A,Indri NV,Astuti SD,Prijo TA .2018 .Optimization of Axial Sequence T2 Gradient Echo Image with Bandwidth Variation and Echo Timeon Shoulder MRI to Reduce Susceptibility Artifacts and Chemical Shift. J Health, 5 : 40-49.
Ieong E,Rafferty M,Khanna M,Walker M,Rosenfeld P .2019 .Use of fat-suppressed T2-weighted MRI images to reduce the magic angle effect in peroneal tendons. Foot Ankle Specialist, 12 : 513-517.
Kijowski R,Rosas H,Samsonov A,King K,Peters R .2017 .Knee imaging: Rapid three dimensional fast spinecho using compressed sensing. J Magnetic Resonance Imaging, 45 : 1712-1722.
Asiri A,Dimpudus F,Atcheson N,Al-Najjar A,McMahon K,Kurniawan ND .2021 .Comparison between 2D and 3D MEDIC for human cervical spinal cord MRI at 3T. J Med Radiation Sci, 68 : 4-12.
Kashif M,Fahmi M,Hariyani DA,Rahmatilah A,Ain K,Susilo Y,SD. Y .2022 .An improved Kalman Filter in Photoplethysmography DC Component Denoising for cardiorespiratory analysis. Rawal Med J, 47 : 741-745.
Chen Y,Li J,Qu X,Chen L,Cai C,Cai S .2013 .Partial Fourier transform reconstruction for single-shot MRI with linear frequency swept excitation. Magnetic Resonance Med, 69 : 1326-1336.
Tang MY,Chen TW,Zhang XM,Huang XH,Article ID .2014 .GRE T2- weighted MRI: principles and clinical applications. Bio Med Res Int Volume, : .