No Detail Found!

Diagnostic accuracy of magnetic resonance imaging in detecting and grading perianal fistulas

Author(s)
Sidra Minhas Departments of Radiology, Cantonment Rawalpindi, Pakistan
Riffat Raja Departments of Radiology, Cantonment Rawalpindi, Pakistan
Maria Khaliq Departments of Radiology, Cantonment Rawalpindi, Pakistan
Hassan Mahmood District Health Officer, Cantonment Rawalpindi, Pakistan
Syed Muhammad Raza Federal Ministry of National Health services, Regulations and Coordination (MNHSRC), Rawalpindi, Pakistan
Hina Hanif Holy Family Hospital, Rawalpindi, Pakistan
Abstract
Objective: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in detecting and grading perianal fistula, taking operative findings as gold standard. Methodology: This descriptive, cross-sectional study was conducted in department of Radiology & Imaging, Holy Family Hospital, Rawalpindi from 09-06-2019 to 08-12-2019. A total of 100 patients underwent MRI on 1.5 tesla GE machine using a pelvic phased array multicoil. Images were interpreted by experienced radiologist to identify and grade perianal fistula. After surgery, findings were recorded for presence/absence of perianal fistula as well as for anatomical details of fistulous tract. MRI findings were compared with operative findings. Data were analyzed using SPSS version 20.0. Results: MRI showed the presence of perianal fistula in 87 patients. Operative findings confirmed perianal fistula in 89 cases where as 11 patients revealed no perianal fistula. Overall sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy (DA) of MRI in detecting perianal fistula were 95.5%, 81.8%, 97.7%, 69% and 94%, respectively. The most common type of fistula was intersphincteric grade 1 fistula. Abscess formation was more common in grade 3, 4 and 5 fistulas. Internal opening of the fistulous track was most commonly identified posteriorly in midline at 6 O’clock position. Conclusion: MRI is a highly sensitive and accurate imaging modality for pre-operative diagnosis and grading of perianal fistula.
Publication Details
Page(s) 647-650
DOI DOI not available
Published Journal: Rawal Medical Journal, Volume: 48, Issue: 3, Year: 2023

Request the full text from PASTIC

Keywords
diagnostic accuracy., Perianal fistula, perianal fistula grading, pelvic MRI
References
Singh K,Singh N,Thukral CL,Singh KP,Bhalla V .2014 .Magnetic resonance imaging (MRI) evaluation of perianal fistulae with surgical correlation. J Clin Diagnostic Res, 8 : RC01-RC04.
Chaudhari NH,Sinkar AD,Swoyam S. .2016 .Role of magnetic resonance imaging in evaluation of perianal fistulas. Int J Res Med Sci, 4 : 482-7.
Chauhan NS,Sood D,Shukla A .2016 .Magnetic resonance imaging (MRI) characterization of perianal fistulous disease in a rural based tertiary hospital of North India. Polish J Radiol, 81 : 611-6.
Bakhtawar N,Usman M. . .Factors increasing the risk of recurrence in fistula-in-ano. Cureus. 2019 Mar, 7(3) : .
Woo S,Moon MH,Cho JY,Kim SH,Kim SY,Feng ST .2019 .-weighted imaging and fat-suppressed T2- weighted imaging image fusion technology improves image discriminability for the evaluation of anal fistulas. Korean J Radiol, 20 : 429-37.
Carvalho AL,Sena NF,Sampaio JC,Trajano AD,Codes LM,Fidelis FD,Coloproctol (Rio de Janeiro) FD .2021 .Profile of Crohn's Disease Patients Who Underwent Anorectal Examination under Anesthesia. , 41 : 275-80.
Akhtar S,Rana A,Latif U,Saleem H,Chaudhary MY .2014 .MRI in the pre-operative evaluation of perianal fistula. J Postgrad Med Inst, 28 : 264-9.
Aggarwal R,Soni BK,Kumar JU,George RA,Sivasankar R. .2017 .MR fistulography with percutaneous instillation of aqueous jelly: A cost effective technique innovation. Indian J Radiol Imaging, 27 : 161-6.
Almeida IS,Jayarajah U,Wickramasinghe DP,Samarasekera DN .2019 .Value of three-dimensional endoanal ultrasound scan (3D-EAUS) in preoperative assessment of fistula-in-ano. BMC Res Notes, 12 : 1-5.
Regadas FS,Murad-Regadas SM .2015 .Commentary on 'Impact of 3-dimensional endoanal ultrasound on the outcome of anal fistula surgery: a prospective cohort study'. Colorectal Dis, 17 : 1112-3.
Balcı S,Onur MR,Karaosmanoğlu AD,Karçaaltıncaba M,Akata D,Konan A .2019 .MRI evaluation of anal and perianal diseases. Diagnostic Interventional Radiol, 25 : 21-7.
Abdelnaby M,Emile SH,Sakr A,Magdy A,Fouda E,Abdelmawla A .2017 .Role of MRI fistulography with gadopentate enhancement in assessment of complex anal fistulas and improving surgical outcomes. J Surg, 5 : 22-7.
Ishfaq S,Qamar MA,Zaman M. Diagnostic .2016 .Accuracy of Magnetic Resonance Imaging in Perianal Fistula Taking Surgical Findings as Gold Standard. Age (years). PJMHS, 10 : 939-41.
Mazroa JA,Elmogy SA,Elgendy MM .2012 .Value of contrast enhanced spoiled gradient (SPGR) MR and MIP MR imaging in diagnosis of peri-anal fistula. Egyptian J Radiol Nuclear Med, 43 : 119-28.
Daabis N,El Shafey R,Zakaria Y,Elkhadrawy O .2013 .Magnetic resonance imaging evaluation of perianal fistula. Egyptian J Radiol Nuclear Med, 44 : 705-11.
Algazzar HY,Eldib DB,Bahram MA,Zaher NA .2019 .Preoperative MRI of perianal fistula evaluation and its impact on surgical outcome. Egyptian J Radiol Nuclear Med, 50 : 1-10.
Mohey N,Hassan TA .2017 .Effectiveness of magnetic resonance imaging in grading of primary perianal fistula and its associated findings in correlation with surgical outcome. Egyptian J Radiol Nuclear Med, 48 : 1-6.
Nelson RL,Abcarian H.,Epidemiology H. .2014 .Incidence and Prevalence of Fistula in Ano. Anal Fistula, : 1-7.
Mohamed RE,Abo-Sheisha DM .2014 .Role of magnetic resonance imaging in pre-operative assessment of anorectal fistula. Egyptian J Radiol Nuclear Med, 45 : 35-47.
Charles P.,Heise Perry J .2012 .Pickhardt, MR Imaging Evaluation of Perianal Fistulas: Spectrum of Imaging Features. Radiographics, 32 : 194-7.
0

Citations

0

Downloads

121

Views