No Detail Found!

Evaluating the general v(λ) mismatch spectral quality factor index f1' and the uncertainty of photometers

Author(s)
Manal A. Haridy Photometry and Radiometry Division, National Institute of Standards (NIS),Giza,Egypt
Abstract
The general term photometry refers to the measurement of light and its perceived brightness; it can be applied to various purposes, including lighting design, display calibration, and the setting of safety standards. A device used for measuring light is called a light meter or photometer. Ideally, such devices should have a spectral responsivity-that is, they should respond to light in a way which mimics the human eye's sensitivity to different wavelengths. The sensitivity of the human eye is described by the Commission Internationale de l'Éclairage, CIE, luminous efficiency function, V(?), a plot of the sensitivity of the eye versus wavelength over the visible region, from violet, approximately 380 nm, through red, approximately 780 nm. In practical applications, it is usually preferable to detect light with silicon or selenium photodetectors and measure the electrical current generated. These photodetectors are sensitive to a wide range of wavelengths, including those outside of the visible spectrum: ultraviolet (UV) and infrared (IR). However, due to its nature, the spectral responsivity of silicon and selenium photodetectors is also different from that of the human eye. For example, silicon photodetectors are much more sensitive to infrared radiation, which is imperceptible to human vision. This in turn leads to erroneous light measurements when using the direct raw response of the detector. The spectral quality factor f1' and f1'' , indicating the mismatch between the spectral responsivity and the CIE luminous efficiency function V(?), is the most crucial characteristic of photometers. The general mismatch index f1' , denoted as V(?), delineates the disparity between a photometer's relative spectral responsivity and the spectral luminous efficiency function for photopic vision, V(?). It's highly probable that photometers will adopt white light-emitting diode (LED) sources as calibration references going forward. This transition may necessitate refining the general V(?) mismatch index's definition, possibly through alternative normalization methods for f1' or by introducing a different assessment function for evaluating mismatches f1'' . In this research, spectral quality factor f1' for the photometer NIS-2 has been determined with value 3.8%. This percentage value is classified the photometer NIS-2 as medium quality. The uncertainty was determined through a calculation performed using my Microsoft Excel program, and the final value obtained is 0.010.
Publication Details
Page(s) 966-974
DOI DOI not available
Published Journal: ARPN Journal of Engineering and Applied Sciences, Volume: 19, Issue: 15, Year: 2024

Request the full text from PASTIC

Keywords
uncertainty, spectral Responsivity of Sphere, spectroradiometers, photometers, photopic response, total luminous flux, spectral quality factor f1', spectral quality factor f1''
References
Thorseth A.,Krüger U.,Ferrero A.,Mantela V.,Sperling A.,Pellegrino O. .2023 .D5: Evaluation of a complementary general V(λ) mismatch index. , : .
CIE. .1987 .CIE69:1987 Methods of Characterizing Illuminance Meters and Luminance Meters: Performance, Characteristics and Specifications. , : .
Krochmann J.,Reissmann K. .1980 .Über den Spektralangleich von Strahlungsempfängern und von Lichtquellen. Optik (Stuttg), 56 : 83-93.
Krystek M.,ERB W. M.,Empfängern Kenngrößen .1980 .. Optik (Stuttg), 54 : 381-388.
Krochmann J.,Rattunde R. .1980 .Über die Güte der V(Lambda)-Anpassung von lichtempfindlichen Empfängern. Licht-Forschung. 2, : 31-37.
Krüger U.,Ferrero A.,Thorseth A.,Mantela V.,Sperling A. .2021 .General V(λ. in: Proceedings of the Conference CIE 2021. International Commission on Illumination, CIE, 10 : 896-906.
Kokka A.,Poikonen T.,Blattner P.,Jost S.,Ferrero A.,Pulli T.,Ngo M.,Thorseth A.,Gerloff T.,Dekker P.,Stuker F.,Klej A.,Ludwig K.,Schneider M.,Reiners T.,Ikonen E. .2018 .Development of white LED illuminants for colorimetry and recommendation of white LED reference spectrum for photometry. Metrologia, 10 : 1681-534.
Weinold M. .2020 .General Electric's exit from lighting business is a warning to other players in the sector. , : .
Krüger U.,Sauter G. .2006 .Comparison of methods for indicating the measurement uncertainty of integral parameters on the basis of spectral data by means of the measurement uncertainty of the f1' value. Proceedings of the 2nd CIE Expert Symposium on Measurement Uncertainty, CIE x029, : 159-163.
Poikonen T.,Kärhä P.,Manninen P. .2009 .Uncertainty analysis of photometer quality factor f1. Metrologia, 46 : 75-80.
Ikonen E.,Poikonen T.,Kärhä P. .2008 .Determination of f1 and its uncertainty with biased and random error models. , : 55-58.
Krüger U.,Blattner P. .2008 .The influence of the uncertainty of the spectral responsivity measurement on the method of determination of f1. CIE Expert Symposium 2008 on Advances in Photometry and Colorimetry. CIE x033., : .
.1995 .Guide to the Expression of Uncertainty in Measurement, First Edition, International Organization for Standardization (ISO).. , : .
.1987 .CIE 69, Methods of characterizing illuminance meters and luminance meters. , : .
Ohno Yoshi .1997 .. , : .
.2014 .2014 Characterization and performance of illuminance meters and luminance meters. , : .
2021(E) Colorimetry .2021 .- Part 2: CIE standard illuminants. ISO/CIE DIS 11664-2, : .
Krüger U.,Blattner P. .2013 .Spectral mismatch correction factor estimation for white led spectra based on the photomers f1' value, in: CIE Centenary Conference towards a New Century of Light. CIE X038-2013, : 300-307.
Krüger U.,Blattner P. .2008 .The Influence of the Uncertainty of The Spectral Responsivity Measurement on the Method of Determination of f1prime, in: CIE Expert Symposium on Advances in Photometry and Colorimetry At: Turin (Italy) Volume: CIE X033. , : 49-54.
Ferrero A.,Campos J.,Pons A.,Velázquez J.L. .2017 .Proposal For A New General V(Λ) Mismatch Index. International Commission on Illumination, CIE, 10(25) : 73-78.
Czibula G.,Makai J. P. .1998 .Novel method to correct inaccuracies of photometer heads for the measurement of LEDs. , 3428 : 121-129.
Young R.,Jones C.,Muray K. .2001 .Quantifying photometric spectral mismatch uncertainties in LED measurements. Proceedings of CIE 2nd Expert Symposium on LEDs. CIE x022. Vienna: CIE, : 39-44.
Csuti P.,Kranicz B.,Schanda J. .2005 .Comparison of the goodness of fit of photometers to the V(λ) function using real LED spectra. Proceedings of the CIE Symposium '04 on LED Light Sources: Physical Measurement and Visual and Photobiological Assessment. CIE x26:2005, : .
Ferrero A.,Velázquez J. L.,Pons A.,Campos J. .2018 .Index for the evaluation of the general photometric performance of photometers Optics Express. , 18633 : 43.
Alkermelawi A.,Alkamel A.,Haridy Manal A. .2023 .. , : .
Manal A.,Haridy A. .2015 .Improvement uncertainty of total luminous flux measurements by determining some correction factors. Int. J. Curr. Res. Aca. Rev, 3(6) : 264-274.
Gardner J. L.,Gardner J. L. J. L. .2000 .Uncertainties in source distribution temperature and correlated color temperature. Metrologia, 43 : 403-407.
Gardner J. L.,Frenkel R. B J. L. .1999 .Correlation coefficients for tristimulus response value uncertainties. Metrologia, 36 : 477-480.
0

Citations

0

Downloads

90

Views