No Detail Found!

Analysis re-entrant honeycomb auxetic structure for lumbar vertebrae using finite element analysis

Author(s)
Ai'man A'siqin Zulkefli Department of Electrical and Electronic Engineering, Universiti Tun Hussien Onn Malaysia,Parit Raja, Johor,Malaysia
Muhammad Hazli Mazlan Department of Electrical and Electronic Engineering, Universiti Tun Hussien Onn Malaysia,Parit Raja, Johor,Malaysia
Hiromitsu Takano Department of Orthopedic Surgery, Juntendo University,Tokyo,Japan
Abdul Halim Abdullah School of Mechanical Engineering, College of Engineering,Universiti Teknologi MARA, Shah Alam,Malaysia
Muhammad Hilmi Jalil Faculty of Mechanical and Automotive Engineering Technology,Universiti Malaysia Pahang, Pekan, Pahang,Malaysia
Mohammad Azeeb Mazlan AA3D Technology Sdn Bhd,Shah Alam, Selangor,Malaysia
Abstract
Lumbar spinal fusion is a frequent surgical solution among people who are experiencing severe persistent lower back pain. One treatment option is Lateral Lumbar Interbody Fusion (LLIF) surgery. In the medical field, finite element analysis (FEA) can be used to predict the best surgical plan. LLIF surgery involves implanting an interbody cage into the disc space, which may potentially move to regain the disk height while helping stabilize the vertebral bones. In this study, FEA was applied using Mechanical Finder software (MF) to develop a 3D spine model lumbar vertebrae of the fourth and fifth lumbar vertebrae (L4 - L5) with the interbody cage design. The cage was made of polyether ether ketone (PEEK) and designed using Solidworks software. Given the auxetic structure's outstanding energy absorption capabilities, a re-entrant auxetic structure core with a novel sandwich panel was implanted between the lumbar vertebrae L4 and L5, as determined by CT scans using MF software. The model was analyzed in MF to assess the strength and fracture risk analysis of the interbody cage, with the results compared to mechanical properties values obtained by applying compression load (1000 N) to simulate spinal movements. Stress and strain distribution rates were exhibited when applying a force of 1000 N. The findings underscore the relevance of cage design, namely the surface endplate, in mitigating undesirable occurrences associated with cage sinking. To attain enough strength under typical conditions, a lumbar cage with a re-entrant auxetic construction has been proposed.
Publication Details
Page(s) 546-555
DOI DOI not available
Published Journal: ARPN Journal of Engineering and Applied Sciences, Volume: 19, Issue: 9, Year: 2024

Request the full text from PASTIC

Keywords
Finite element analysis, fracture risks, sandwich panel, re-entrant auxetic structure
References
Alexander Abhijit P.,Federico H.,Andrew G.,Darren S.,Frank L.,C. L. .2015 .Lateral Lumbar Interbody Fusion-Outcomes and Complications _ Enhanced Reader. ASIAN SPINE JOURNAL, 9(6) : 978-983.
Darren G.,R. L. G.,and Frank P. C. G. .2015 .A Comparison study of LLIF and PLIF in Degenerative Lumbar Spondylolisthesis. Asian Spine Journal, : 668-674.
Agarwal N.,White M. D.,Zhang X.,Alan N.,Ozpinar A.,Salvetti D. J.,Tempel Z. J.,Okonkwo D. O.,Kanter A. S.,Hamilton D. K. .2020 .Impact of endplateimplant area mismatch on rates and grades of subsidence following stand-alone lateral lumbar interbody fusion: An analysis of 623 levels. Journal of Neurosurgery: Spine, 33(1) : 12-16.
Battié M. C.,Joshi A. B.,Gibbons L. E. .2019 .. , : .
. .. Degenerative Disc Disease: What is in a Name? Spine, 44(21) : 1523-1529.
Kerr A.,Wadhwa E.,Stone R.,M. R. .2020 .PEEK versus titanium cages in lateral lumbar interbody fusion: A comparative analysis of subsidence. Neurosurgical Focus, 49(3) : .
Chen Y.,Wang Z. W. .2022 .In-plane elasticity of the re-entrant auxetic hexagonal honeycomb with hollowcircle joint. Aerospace Science and Technology, 123 : .
Harrysson Yang L.,West O.,Cormier H.,D. H. .2015 .. , : .
. .Mechanical properties of 3D re-entrant honeycomb auxetic structures realized via additive manufacturing. , : .
. .. International Journal of Solids and Structures, 69 : 70.
.2015 .. , 05 : .
0

Citations

0

Downloads

82

Views