No Detail Found!

An analysis of clinical application effects of 3d-printed act titanium trabecular intervertebral fusion cage in posterior lumbar interbody fusion (PLIF)

Author(s)
Zhijun Li School of Graduates, Dalian Medical University, Dalian, 116044, Liaoning, China; Department of Orthopedics, The Second People’s Hospital of Dalian, Dalian, 116011, Liaoning, China.
Hong Wang Department of Orthopedics, Dalian Municipal Central Hospital Affiliated of Dalian Medical University, Dalian 116011, Liaoning, China.
Zhaoqi Wang Department of Physiatry, The Second People’s Hospital of Dalian, Dalian 116011, Liaoning, China.
Zhiming Qi Department of Orthopedics, The Second People’s Hospital of Dalian, Dalian 116011, Liaoning, China.
Qi Yao Department of Orthopedics, The Second People’s Hospital of Dalian, Dalian 116011, Liaoning, China.
Abstract
Objective: To compare the clinical efects of applying a 3D-printed ACT titanium trabecular intervertebral fusion cage and a Polyetheretherketone (PEEK) cage in posterior lumbar interbody fusion (PLIF). Methods: This was a clinical comparative study. Forty patients with degenerative lumbar diseases admitted at The Second People's Hospital of Dalian from January 2020 to December 2021 were selected and divided into an observation group (3D cage) and a control group (PEEK cage) using the random number table method, with each group of 20 cases. The visual analogue scale (VAS) scores, Japanese Orthopaedic Association (JOA) scores, Cobb angles at fusion segments, intervertebral height and intervertebral fusion situations of the patients between the groups were compared. Results: No significant diferences were found in their operation time, intraoperative blood losses and operation related complications(p>0.05). In terms of postoperative VAS and JOA scores in both groups, they are all significantly improved compared with those before the operation, and their diferences are also statistically significant( p<0.05). However, no statistical significance exists in inter-group diferences(p>0.05). Postoperative Cobb angles and intervertebral height of patients in both groups are considerably bettered compared with those before the operation. Their diferences show statistical significance( p<0.05), while inter-group diferences are proved to be not statistically significant(p>0.05). Conclusions: Applying a 3D-printed ACT titanium trabecular intervertebral fusion cage or PEEK cage in PLIF has the potential to improve clinical symptoms of patients with degenerative lumbar diseases, and restore the Cobb angle and intervertebral height. 3D-printed ACT titanium trabecular intervertebral fusion cage can accelerate intervertebral fusion without increasing operation related complications.
Publication Details
Page(s) 1791-1796
Published Journal: Pakistan Journal of Medical Sciences, Volume: 40, Issue: 8, Year: 2024

Request the full text from PASTIC

Keywords
Posterior lumbar interbody fusion (PLIF), 3D printing, Polyetheretherketone (PEEK), titanium trabecula, intervertebral fusion cage
References
Reid PC,Morr S,Kaiser MG .2019 .State of the union: a review of lumbar fusion indications and techniques for degenerative spine disease. J Neurosurg Spine, 10(1) : 1-14.
Seo DK,Kim MJ,Roh SW,Jeon SR .2017 .Morphological analysis of interbody fusion following posterior lumbar interbody fusion with cages using computed tomography. Medicine (Baltimore), 10(34) : .
Smit TH,Müller R,van Dijk M,Wuisman PI .2003 .Changes in bone architecture during spinal fusion: three years follow-up and the role of cage stiffness. Spine (Phila Pa, 0000083285(16) : 1802-1809.
Tu P,Cao S,Jiang C,Yan CC C .2021 .A comparative study of Lumbar Decompression and Fusion with Internal Fixation versus Simple Decompression in elderly patients with two-segment Lumbar Spinal Stenosis. Pak J Med Sci, 10(1) : 2287-260.
Park HJ,Kim SK,Lee SC,Kim W,Han S,Kang SS .2020 .Dural Tears in Percutaneous Biportal Endoscopic Spine Surgery: Anatomical Location and Management. , 01 : e578-e585.
Seaman S,Kerezoudis P,Bydon M,Torner JC,Hitchon PW .2017 .Titanium vs. polyetheretherketone (PEEK) interbody fusion: Meta-analysis and review of the literature. J Clin Neurosci, 06 : 23-29.
Kulkarni AG,Bohra H,Dhruv A,Sarraf A,Bassi A,Patil VM .2016 .Minimal invasive transforaminal lumbar interbody fusion versus open transforaminal lumbar interbody fusion. Indian J Orthop, 10(5) : 189607-5413.
Igarashi H,Hoshino M,Omori K,Matsuzaki H,Nemoto Y,Tsuruta T .2019 .. Factors Influencing Interbody Cage Subsidence Following Anterior Cervical Discectomy and Fusion. Clin Spine Surg, 10(7) : 297-302.
Li P,Jiang W,Yan J,Hu K,Han Z,Wang B .2019 .A novel 3D printed cage with microporous structure and in vivo fusion function. J Biomed Mater Res A, 36652(7) : 1386-1392.
Arts M,Torensma B,Wolfs J .2020 .Porous titanium cervical interbody fusion device in the treatment of degenerative cervical radiculopathy; 1-year results of a prospective controlled trial. Spine J, 03(7) : 1065-1072.
van den Brink W,Lamerigts N.,Printed Porous Titanium Cervical Cage D .2020 .Complete Osseointegration of a Retrieved 3. Front Surg, 10 : 526020.
Shen Z,Guan X,Wang R,Xue Q,Zhang D,Zong Y .2022 .Effectiveness and safety of decompression alone versus decompression plus fusion for lumbar spinal stenosis with degenerative spondylolisthesis: a systematic review and meta-analysis. Ann Transl Med, 10(12) : 664.
Kim MC,Chung HT,Cho JL,Kim DJ,Chung NS .2013 .Subsidence of polyetheretherketone cage after minimally invasive transforaminal lumbar interbody fusion. J Spinal Disord Tech, 10(2) : 87-92.
Pijpker PAJ,Kuijlen JMA,Kraeima J,Groen RJM,Faber C.,Extrapedicular Screw Insertion C. .2022 .A Comparison of Drill Guiding and Screw Guiding 3D-Printing Techniques for Intra-. Spine (Phila Pa, 10(10) : E434-E441.
McGilvray KC,Easley J,Seim HB,Regan D,Berven SH,Hsu WK .2018 .Bony in growth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model. Spine J, 02(7) : 1250-1260.
Deng QX,Ou YS,Zhu Y,Zhao ZH,Liu B,Huang Q .2016 .Clinical outcomes of two types of cages used in transforaminal lumbar interbody fusion for the treatment of degenerative lumbar diseases: n-HA/PA66 cages versus PEEK cages. J Mater Sci Mater Med, 10(6) : 102.
Jin YZ,Zhao B,Lu XD,Zhao YB,Zhao XF,Wang XN .2021 .Mid- and Long-Term Follow-Up Efficacy Analysis of 3D-Printed Interbody Fusion Cages for Anterior Cervical Discectomy and Fusion. Orthop Surg, 10(7) : 1969-1978.
Adl Amini D,Moser M,Oezel L,Zhu J,Okano I,Shue J .2021 .Early Outcomes of Three-Dimensional-Printed Porous Titanium versus Polyetheretherketone Cage Implantation for Stand-Alone Lateral Lumbar Interbody Fusion in the Treatment of Symptomatic Adjacent Segment Degeneration. , 11 : e14-e20.
Zheng Y,Han Q,Wang J,Li D,Song Z,Yu J .2020 .Promotion of Osseointegration between Implant and Bone Interface by Titanium Alloy Porous Scaffolds Prepared by 3D Printing. ACS Biomater Sci Eng, 10(9) : 5181-5190.
Zippelius T,Strube P,Suleymanov F,Putzier M .2019 .Hölzl A. Safety and efficacy of an electron beam melting technique-manufactured titanium mesh cage for lumbar interbody fusion. Orthopade, 10(2) : 150-156.
Li Zhijun,Liaoning Zhijun,Liaoning Zhijun . .. The Second People's Hospital of Dalian, Dalian, 116011 : .
Hong Wang,Liaoning Wang . .. , : .
Zhaoqi Wang . .. , : .
Qi Zhiming . .. , : .
Yao Qi . .. , : .
Liaoning . .3-5: The Second People's Hospital of Dalian, Dalian 116011. , : .
0

Citations

0

Downloads

91

Views