No Detail Found!

Comparison of treatment of volar Barton's fracture with T plate using distal end screws and without distal end screws

Author(s)
Sajjad Haider Department of Orthopedic Surgery, Mayo Hospital, Lahore, Pakistan.
Muhammad Zarak Awais Department of Orthopedic Surgery, Mayo Hospital, Lahore, Pakistan
Eman Salik Department of Orthopedic Surgery, Mayo Hospital, Lahore, Pakistan.
Muhammad Tahir Iqbal Department of Orthopedic Surgery, Mayo Hospital, Lahore, Pakistan.
Abstract
Objective: To compare the functional and radiological outcomes of treatment of volar Barton's fractures using T plate with and without distal end screws. Methods: This randomized control trial was conducted at the department of Orthopedics, Mayo Hospital, Lahore, Pakistan from December 2021 to May 2022. Total 60 patients (30 in each group) were randomly allocated to either group A (T-Plate with distal end screws) or B (T-Plate without distal end screws). Patients were followed up on day-0, day-14, day-28 and day-90. Assessments of patients were done by Green O'Brien Score for pain, Modified Warden Score for callus formation on radiographs at 12-weeks of follow-up and Stewart Score for displacement of fracture. Results: At 90th day, significant diference was seen in Green O'Brien Score (Excellent score: Group-A: 80% vs. Group-B: 90%, p=0.278) while Stewart scores remained comparable (Excellent Score: Group-A: 93.33% vs. Group-B: 96.67%, p=0.221) between treatment groups. Fracture healing assessed with Modified Warden score for score 4 did not show significant diference between both groups at 90 th day. i.e. (Group-A: 96.67% vs. Group-B: 96.67%). However, callus formation assessed with Modified Warden score for score 3 showed significant diferences between groups at 90 th day. i.e. (Group-A: 53.33% vs. Group-B: 86.67%, p=0.001). Conclusion: Both treatment approaches appear to yield comparable outcomes in terms of clinical assessment, Stewart scores, and fracture healing, with a potential advantage for T-plate without distal end screw in callus formation at the 90th day.
Publication Details
Page(s) 1797-1801
Published Journal: Pakistan Journal of Medical Sciences, Volume: 40, Issue: 8, Year: 2024

Request the full text from PASTIC

Keywords
hand, T-plate, Distal end, Volar Barton's fracture, screws
References
Shaikh SA,Tahir M,Ahmed N,Maniglio M. .2023 .Conservative management versus volar plating for dorsally displaced distal radius fractures in the elderly: A randomized control trial. doi: 10.12669/pjms.39.3.6522, 39(3) : .
Murugesan AK GR,Ismail PY .2019 .Open reduction and internal ifxation of volar Barton's fractures by polyaxial locking plates: a retrospective study. Inte J Res Orthopaed, 10(5) : 4510-804.
Masood F,Sah RK,Sarfaraz AH,Shah H,Chavali V,Daveshwar R. Adolescent V .2015 .Volar Barton Fracture with Open Physis treated with Volar Plating using Buttressing Principle. Ann King Edward Med Uni, 10(2) : 47-50.
Mallepogu Kolla R AP,Thadi RK,Tej RR,A RR,Saravanan P. .2019 .A Study of The Management of Distal Radius Fractures as Per AO Classification in A Tertiary Care Centre. J Evid Based Med Healthc, 10(8) : 534.
Orthopedics and Rheumatology Open .2019 .. , 14(1) : 1-6.
.2019 .. doi:10, 14 : .
Khatri K,Sharma V,Farooque K,Tiwari V .2016 .Surgical treatment of unstable distal radius fractures with a Volar variable-angle locking plate: Clinical and radiological outcomes. Arch Trauma Res, 10(2) : .
Sahito B,Tariq SM,Mamji F,Doultani D,Ali M,Hussain N. .2015 .Outcome of open reduction and internal fixation of volar Barton fracture treated with Buttress plate. Rawal Med, 40(4) : 406-408.
Aggarwal AK,Nagi ON .2004 .Open reduction and internal fixation of volar Barton's fractures: a prospective study. J Orthop Surg (Hong Kong), 10(2) : 230-234.
Karthik SJ,Ethiraj P.,Do Variable Locking Plates Provide Better Functional P. .2022 .. , 10(11) : .
Chang FS,Chen CH,Lee CH,Lee KT,Cho YC .2020 .Evaluating the necessity of bone augmentation for distal radius fracture fixed with a volar locking plate: a retrospective study. BMC Musculoskelet Disord, 10(1) : 180.
Orbay JL,Fernandez DL .2002 .Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am, 10(2) : 205-215.
Sakhaii M,Groenewold U,Klonz A,Reilmann H .2003 .Eine prospektive Studie results after palmar plate-osteosynthesis with angularly stable T-plate in 100 distal radius fractures: a prospective study. Unfallchirurg, 10(4) : 272-280.
Khan MA,Ghilzai AK,Shah SKA,Rahim MK .2018 .Benefits of Palmer T-Plate osteosynthesis in unstable distal radius fracture management. Biomed J Sci Tech Res, 2(3) : 000766-2672.
Pillai HB,Sankar S,Rawat SS,Arya S,Jadhav P. .2020 .The functional outcome volar barton fracture treated by open reduction and internal fixation with T Plate-A prospective study. J Contemp Med Res, 7(6) : 6-F11.
Salibian AA,Bruckman KC,Bekisz JM,Mirrer J,Thanik VD,Hacquebord JH .2019 .Management of Unstable Distal Radius Fractures: A Survey of Hand Surgeons. J Wrist Surg, 10(4) : 335-343.
Leung F,Tu YK,Chew WY,Chow SP .2008 .Comparison of external and percutaneous pin fixation with plate fixation for intra-articular distal radial fractures. A randomized study. J Bone Joint Surg Am, 01581(1) : 16-22.
0

Citations

0

Downloads

106

Views