No Detail Found!

Design Adjustments For Daylighting and Visual Comfort in a Classroom with Conventional Shadings

Author(s)
Doris A. Chi Department of Architecture, Universidad de las Americas Puebla,ExHacienda Santa Catarina Martir S/N, San Andres Cholula, 72810,Mexico
Abstract
This paper evaluates how design adjustments applied to roller shades and louvres (namely the height of the shadings head and the angles of the louvre slats) can improve their annual and spatial effectiveness to provide autonomous daylight levels, reduce daylight glare problems, and offer views outside. The strategies were analogous to the rule of thumb that relates the window head height with the depth of daylight penetration. Climate-based daylight simulations were performed to calculate the Useful Daylight Illuminance, spatial Disturbing Glare, and View Factors in a classroom located at a 19° latitude. Temporal maps were included to assess the shadings' performance not only over space but also over time. Results showed that roller shades performed better when they were applied letting the top of the window clear. On the contrary, louvres performed better when they covered the entire glazing. It is concluded that simple design adjustments can greatly improve the daylight and visual performance in buildings.
Publication Details
Page(s) 165-180
Published Journal: Journal of Daylighting, Volume: 11, Issue: 1, Year: 2024

Request the full text from PASTIC

Keywords
Spatial disturbing glare, Uniformity, Shading design, Useful daylight illuminance
References
EC (European Commission) .2010 .. , : .
Nicoletti F.,Carpino C.,Cucumo M.A.,Arcuri N. .2020 .The control of venetian blinds: A solution for reduction of energy consumption preserving visual comfort. Energies, 13(7) : 1731.
Uribe D.,Vera S.,Bustamante W.,McNeil A.,G. A. .2019 .Flamant, Impact of different control strategies of perforated curved louvers on the visual comfort and energy consumption of office buildings in different climates. Solar Energy 190, : 495-510.
Giovannini L.,Favoino F.,Lo Verso V.R.M.,Pellegrino A.,Serra V. .2018 .A simplified approach for the annual and spatial evaluation of the comfort classes of daylight glare using vertical illuminances. Buildings, 8(12) : 171.
Kim G.,H.S. Lim, G. .2010 .Predicted performance of shading devices for healthy visual environment. Indoor and Built Environment, 19 : 486-496.
Kuhn T.E. .2017 .State of the art of advanced solar control devices for buildings. Solar Energy 154, : 112-133.
Kirimtat A.,Koyunbaba B.,Sariyildiz S. .2016 .Review of simulation modeling for shading devices in buildings. Renewable and Sustainable Energy Reviews, 53 : 23-49.
Simmler H.,Binder B. .2008 .Experimental and numerical determination of the total solar energy transmittance of glazing with venetian blind shading. Building and Environment, 43(2) : 197-204.
Tzempelikos A.,Athienitis A.K. .2007 .The impact of shading design and control on building cooling and lighting demand. Solar Energy, 81(3) : 369-382.
Lee E.S.,Tavil A. .2005 .Energy and visual comfort performance of electrochromic windows with overhangs. Building and Environment, 42(6) : 2439-2449.
Tsikra P. .2017 .Investigation of the Energy Saving Potential in Existing School Buildings in Greece. The role of Shading and Daylight Strategies in Visual Comfort and Energy Saving. Procedia Environment Sciences, 38 : 204-211.
Lee K.S.,Han K.J.,Lee J.W. .2017 .The impact of shading type and azimuth orientation on the daylighting in a classroom-focusing on effectiveness of façade shading, comparing the results of DA and UDI. , 10(5) : 635.
Freewan A.Y. .2014 .Impact of external shading devices on thermal and daylighting performance of offices in hot climate regions. Solar Energy 102, : 14-30.
Montaser Koohsari A.,Heidari S. .2022 .Subdivided venetian blind control strategies considering visual satisfaction of occupants, daylight metrics, and energy analyses. Energy and Buildings, 257 : 111767.
Palmero-Marrero A.I.,Oliveira A.C. .2010 .Effect of louver shading devices on building energy requirements. Applied Energy, 87(6) : 2040-2049.
A.K.K. Lau E.,Salleh C.H.,Lim M.Y.,Sulaiman M.Y. .2016 .Potential of shading devices and glazing configurations on cooling energy savings for high-rise office buildings in hot-humid climates: The case of Malaysia. International Journal of Sustainable Built Environment, 5(2) : 387-399.
Kim J.H.,Park Y.J.,Yero M.S.,Kim K.W. .2009 .An experimental study on the environmental performance of the automated blind in summer. Building and Environment, 44(7) : 1517-1527.
Haldi F.,Robinson D. .2010 .Adaptive actions on shading devices in response to local visual stimuli. Journal of Building Performance Simulation, 3(2) : 135-153.
Moore T.,Carter D. J.,A. I. D. J. .2003 .Slater, Long-term patterns of use of occupant controlled office lighting. Lighting Research and Technology, 35(1) : 43-57.
Kim D.W.,Park C.S. .2012 .Comparative control strategies of exterior and interior blind systems. Lighting Research and Technology, 44(3) : 291-308.
Sadeghi S.A.,Karava P.,I. Konstantzos P.,Tzempelikos A. .2016 .Occupant interactions with shading and lighting systems using di erent control interfaces: A pilot field study. Building and Environment, 97 : 177-195.
Reinhart C.,Voss K. .2003 .Monitoring manual control of electric lighting and blinds. Lighting Research and Technology, 35(3) : 243-258.
Guillemin A.,Molteni S. .2002 .An energy-efficient controller for shading devices self-adapting to the user wishes. Building and Environment, 37 : 1091-1097.
Bakker L.G.,Hoes-van E.C.M.,Hensen J.L.M. .2014 .User satisfaction and interaction with automated dynamic facades: a pilot study. Building and Environment, 78 : 44-52.
C. F. Reinhart .2005 .A simulation-based review of the ubiquitous window-headheight to daylit zone depth rule-of-thumb. in: International Building Performance Simulation Association (IBPSA), : 1011-1018.
Andersen M. .2006 .Goniophotometry and assessment of bidirectional photometric properties of complex fenestration systems. Energy and Buildings, 38(7) : 836-848.
USGBC (United States Green Building Council LEED .2024 .-construction-schools-newconstruction-retail-new-construction-data-centers-new-9 International WELL Building Institute. Explore the Standard - Feature 62. Accessed: Jun. 10, : .
Funding Education .2024 .Agency (EFA), EFA daylight design guide Departmental advice. , 10 : .
.2016 .design_guide.pdf Building Research Establishment Environmental Assessment Method (BREEAM), Hea 01 Visual comfort (all buildings). , : .
Nabil A.,Mardaljevic J. .2006 .Useful daylight illuminances: A replacement for daylight factors. Energy and Buildings, 38(7) : 905-913.
Reinhart C.,Mardaljevic J.,Rogers Z. .2006 .Dynamic daylight performance metrics for sustainable building design. Leukos, 3(1) : 7-31.
P.M. Esquivias D.,Moreno J.,Navarro J. .2018 .Solar radiation entering through openings: Coupled assessment of luminous and thermal aspects. Energy and Buildings, 175 : 208-218.
Wienold J.,Christoffersen J. .2006 .Evaluation methods and development of a new glare predicton model for daylight environments with the use of ccd cameras. Energy and Building, 38(7) : 743-757.
Solemma LLC .2021 .ClimateStudio User Guide. , 13 : .
Kleindienst S.,Bodart M.,Andersen M. .2008 .Graphical display for annual climate-based daylight simulation. in: Proceedings of eSim 2008-5th National Conference of IBPSA, : 1-8.
Mardaljevic J. .2003 .Precision modeling of parametrically defining solar shading systems: Pseudo-Changi. in: 8th IBPSA Conference Proceedings, : .
. .. , : 830.
0

Citations

0

Downloads

30

Views