No Detail Found!

Influence of time, temperature and humidity on the accuracy of alginate impressions

Author(s)
Muhammad Waqar Hussain Department of Prosthodontics, Bakhtawar Amin Medical & Dental College,Multan-,Pakistan
Saurabh Chaturvedi Department of Prosthodontics, College of Dentistry, King Khalid University,Abha-Kingdom of,Saudi Arabia
Talib Amin Naqash Department of Prosthodontics, College of Dentistry, King Khalid University,Abha-Kingdom of,Saudi Arabia
Abdul Razzaq Ahmed Department of Prosthodontics, College of Dentistry, King Khalid University,Abha-Kingdom of,Saudi Arabia
Gotam Das Department of Prosthodontics, College of Dentistry, King Khalid University,Abha-Kingdom of,Saudi Arabia
Muhammad Haseeb Rana Department of Prosthodontics, College of Dentistry, King Khalid University,Abha-Kingdom of,Saudi Arabia
Adel M. Abdelmonem Department of Prosthodontics, College of Dentistry, King Khalid University,Abha-Kingdom of,Saudi Arabia
Abstract
Background The goal of the current in vitro study was to assess the dimensional accuracy of dental impressions when stored at different times, temperature and humidity. Methods: Impressions were poured to an aluminium triangular die and three teeth placed at the three corners of the die. A total of 130 impressions were made, in wh ich 10 were poured immediately following manufacturers' instructions and the remaining 120 specimens were divided into two groups on the basis of relative humidity during storage. Group -1: 100%, Group-2: 50% relative humidity. Impression was poured with type IV gypsum. The below points were chosen to determine the length between in each of the specimens using the traveling microscope with 10x magnifications after 24 hours of model recovery for calculating the effect of changes in storage conditions- relative humidity, temperature and delay in pouring the impressions, on dimensional accuracy. Results: Analysis of the results revealed that the casts achieved by pouring alginate impressions without delay were most accurate than the delay pouring. With the increase in temperature and time, the distance between the points increased and the casts obtained were bigger. Conclusion: Irreversible hydrocolloids should be poured immediately for optimum dimensional stability.
Publication Details
Page(s) 659-667
DOI DOI not available
Published Journal: Journal of Ayub Medical College, Volume: 32, Issue: S1, Year: 2020

Request the full text from PASTIC

Keywords
Irreversible hydrocolloid, Dimensional accuracy, Dental Impressions