No Detail Found!

Clinical accuracy of bedside Ultrasonography in the diagnosis causes of acute RIF pain at emergency departments

Author(s)
Qurain Turki Alshammari Department of Diagnostic Radiology, College of Applied Medical Sciences, University of Hail, Hail, Saudi Arabia
Moawia Gameraddin Department of Diagnostic Radiologic Technology, Faculty of Applied Medical Sciences, Taibah University, Al-Madina, Saudi Arabia
Mowada Burai Department of Diagnostic Radiology, Faculty of Radiological Sciences and Medical Imaging, Alzaiem Alazhari University, Khartoum, Sudan
Meshari T Alshammari Department of Diagnostic Radiology, College of Applied Medical Sciences, University of Hail, Hail, Saudi Arabia
Ali Suliman Department of Diagnostic Radiologic Technology, Faculty of Applied Medical Sciences, Taibah University, Al-Madina, Saudi Arabia
Fahad Alhazmi Department of Diagnostic Radiologic Technology, Faculty of Applied Medical Sciences, Taibah University, Al-Madina, Saudi Arabia
Awadia Gareeballah Department of Diagnostic Radiologic Technology, Faculty of Applied Medical Sciences, Taibah University, Al-Madina, Saudi Arabia
Amjad R. Alyahyawi Department of Diagnostic Radiology, College of Applied Medical Sciences, University of Hail, Hail, Saudi Arabia; Centre for nuclear and radiation physics, Department of physics, University of Surrey, Guildford, Surry, GU2 7XH, UK
Bushra Abdulmalik Department of Diagnostic Radiology, College of Applied Medical Sciences, University of Hail, Hail, Saudi Arabia
Abstract
Right iliac fossa (RIF) pain is a common clinical ailment in the emergency department. Abdominal Ultrasound (US) is a non-invasive, lively, functional, and secure procedure with zero radiation to patients. Though clinically it is difficult to diagnose its cause, the US is considered the first-line imaging modality used to find the etiology of RIF pain. At the end of this research, the accuracy of the US imaging in the diagnosis of acute RIF pain with respect to the relevant laboratory and clinical findings and intraoperative observations was verified. This is a multi-centered prospective cohort study conducted in three Khartoum State hospitals. One hundred patients with acute RIF pain attending the emergency department were included. The patients were examined by two emergency physicians trained in Ultrasonography. After clinical examination and routine laboratory investigations, a full grid pattern US scan of the abdominal cavity was performed. SPSS statistical software 23.0 version was used for the analysis of the data. The sonographic findings were then compared with the outcome of the surgery. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were determined. The incidence of RIF pathologies is common in the third and fourth decades of life (45% and 27%), respectively. Appendicitis and lower ureteric stones were more prevalent in males than females (41.2% and 35.3% vs. 8.2% and 6.1%). The hemorrhagic ovarian cyst was the most etiology of RIF's pain in females compared to appendicitis (34.7% vs. 8.2%). The US diagnostic performance for RIF pathologies had a sensitivity of 88.40%, 77.41% specificity, 89.7% PPV, 75% NPV, the area under the curve (AUC) of 0.82.4, and overall accuracy of 85%. Appendicitis, lower ureteric stones, hemorrhagic ovarian cysts, and pelvic inflammatory disease were the most commonly diagnosed etiologies of RIF's pain. Bedside US proved to have high sensitivity, specificity, and accuracy for diagnosing the pathologies of the RIF.