No Detail Found!

Calibration and simulation of cut-throat flumes to measure discharge.

Author(s)
Rubina Siddiqui International Water Management Institute, Hyderabad, Pakistan
Bakhshal Khan Lashari Institute of Irrigation & Drainage Engineering, Mehran University of Engineering & Technology, Jamshoro, Pakistan
Khalifa Qasim Laghari Department of Civil Engineering, Mehran University of Engineering & Technology, Jamshoro, Pakistan
Abstract
In this study, newly fabricated portable CTFs (Cut-Throat Flumes) of different sizes have been developed and calibrated for discharge measuring purpose. Flow characteristics of a simplified constricted width flow meter are investigated. The most important dimensions throat width, piezometer taps, and upstream to downstream converging and diverging rate of the flume are precisely established by using the Internal Calipers and Vernier Calipers. The flumes are calibrated and discharge correction factor (relevant to flume width, W) for free and submerged flow conditions are developed and corrected equations for measuring rate of flow through small distributaries are recommended. The discharge-rating factors with respect to upstream head for various size flumes (4”x3’, 8”x3’,12”x3’ and 16”x3’) are practically verified and suggested.
Publication Details
Page(s) 385-392
DOI DOI not available
Published Journal: Mehran University Research Journal of Engineering and Technology, Volume: 28, Issue: 3, Year: 2009

Request the full text from PASTIC

0

Citations

0

Downloads

38

Views