No Detail Found!

Comparision between normal concrete and concrete containing recycled plastic aggregates (Electronic Waste & HDPE) as a partial replacement of natural coarse aggregates

Author(s)
Syed Nasir Abbas Departmen of Engineering Technology, College of Engineering and Technology, University of Sargodha, Sargodha, Pakistan
Muhammad Jahanzeb Departmen of Engineering Technology, College of Engineering and Technology, University of Sargodha, Sargodha, Pakistan
Usman Sarfraz Departmen of Engineering Technology, College of Engineering and Technology, University of Sargodha, Sargodha, Pakistan
Muhammad Waqas Departmen of Engineering Technology, College of Engineering and Technology, University of Sargodha, Sargodha, Pakistan
Zohaib Akhtar Departmen of Engineering Technology, College of Engineering and Technology, University of Sargodha, Sargodha, Pakistan
Umair Hussain Departmen of Engineering Technology, College of Engineering and Technology, University of Sargodha, Sargodha, Pakistan
Hassan Riaz Departmen of Engineering Technology, College of Engineering and Technology, University of Sargodha, Sargodha, Pakistan
Abstract
Nowadays, the demand of infrastructure is increasing day by day. The fundamental component in the construction of any infrastructure is concrete. Due to the widespread use of concrete as the main building material, the availability of raw materials is being questioned. The relationship between supply and demand for a material is rapidly increasing. Thus, in order to overcome the demand for natural materials such as aggregate, alternatives to this material must be sought. On the other hand, the generation of e-waste (e-waste) is also an emerging problem that poses serious environmental problems. The generation of e-waste is a very serious problem in the world. Electronic waste (E-Waste) was selected in this study to ensure its possible use as an additive in concrete construction. The study used an experimental research design to carry out its work. E-Waste was passed through various stages which turned it into particles around 20mm size. The shredded E-waste was used in concrete at 10%, 20% and 30% by weight of conventional coarse aggregate. Four types of concrete samples were made, including the control. The flexural and compressive strength of the concrete specimens was tested after a curing period of 7 days, 14 days, and 28 days, respectively. The result showed that a concrete sample containing 10% E-waste by weight showed higher compressive strength than other samples. The flexural strength of the concrete samples containing E-Waste aggregate was lower than that of the control concrete. The wider use of these wastes leads to a decrease in the demand for natural resources used in concrete.
Publication Details
Page(s) 111-122
DOI DOI not available
Published Journal: Science International, Volume: 33, Issue: 2, Year: 2021

Request the full text from PASTIC

Keywords
Compressive Strength, Tensile Strength, Flexural strength., Electronic waste, partially replacement
0

Citations

0

Downloads

31

Views