COMPARISON OF INCIDENCE OF STERNAL WOUND DEHISCENCE AFTER SIMPLE INTERRUPTED STERNAL CLOSURE VS FIGURE-OF-EIGHT STERNAL CLOSURE IN PATIENTS OF CORONARY ARTERY BYPASS GRAFT SURGERY

Author(s)
Muhammad Ashfaq Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Nasir Ali Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Asif Mahmood Janjua Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Naser Ali Khan Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Ali Gohar Zamir Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Rehana Javaid Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Abstract
Objective: To compare the incidence of sternal wound dehiscence between simple interrupted vs. figure-of-eight sternal closure techniques for median sternotomy in patients undergoing coronary artery bypass graft surgery. Study Design: Comparative prospective, randomized control trial. Place and Duration of Study: Study conducted at Department of Cardiac Surgery, Armed Forces Institute of Cardiology Rawalpindi, from Apr to Dec 2019. Methodology: A total of 206 patients were included in study. These patients were divided into two groups; group “A”: cases which will undergo simple interrupted sternal wire closure technique (n1=103). Group “B”: cases which will undergo figure-of-eight sternal wire closure technique (n2 = 103). Results: There were no statistical difference in the pre-operative data of the patients. The incidence of sternal wound dehiscence in simple interrupted closure was 6.79% while in figure of eight closure technique it was noted to be 1.94%. A statistically significant difference was noted in both the closure technique (p<0.05). Conclusions: Figure-of-eight sternal wire closure technique provides better strength and stability to sternum along with reduced incidence of sternal wound dehiscence as compare to simple interrupted wire closure.
Publication Details
Page(s) 726-730
DOI DOI not available
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 70, Issue: S4, Year: 2020

Request the full text from PASTIC

Keywords
Incidence, Sternal wound, Coronary artery bypass graft, Dehiscence