No Detail Found!

EARLY MORTALITY & MORBIDITY IN MITRAL VALVE REPLACEMENT WITH TOTAL SUB-VALVULAR APPARATUS PRESERVATION, PARTIAL PRESERVATION AND NO PRESERVATION - A COMPARATIVE STUDY

Author(s)
Muhammad Ashfaq Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Nasir Ali Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Asif Mahmood Janjua Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Naser Ali Khan Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Muhammad Imran Ashgar Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Kifayat Ullah Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Yasir Javed Armed Forces Institute of Cardiology/National Institute of Heart Disease (AFIC/NIHD)/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Abstract
Objective: To compare the early morbidity & mortality of total sub-valvular apparatus preservation technique vs partial preservation technique and no preservation technique in mitral valve replacement. Study Design: Cross-sectional comparative study. Place and Duration of Study: Department of Cardiac Surgery, Armed Forces Institute of Cardiology Rawalpindi, from Jan 2017 to Dec 2018. Methodology: One hundred fifty seven patients who underwent Mitral valve replacement were included in study. These patients were divided into three groups; group “A” comprised of those patients with total subvalvular apparatus preservation (n1=46), group “B” comprised of those patients with partial sub-valvular apparatus preservation (n2=70), group “C” comprised of those patients with no sub-valvular apparatus preservation (n3=41). Results: There were no statistical difference in the pre-operative data of the patients. No statistical difference noted in cross clamp & bypass time (p>0.05). The early morbidity in terms of ICU stay, Ventilation time, Inotropic supports, post-operative bleeding, Blood transfusion, postoperative rhythm abnormality & Re-exploration were statically significant (p<0.05). The mortality rate of patients with total sub-valvular apparatus preservation was 2.17% which is significantly less than those with partial preservation (2.85%) & no preservation (9.75%). Conclusions: Mitral valve replacement with total subvalvular apparatus preservation had low postoperative morbidity & mortality in comparison with partial and no preservation techniques.
Publication Details
Page(s) 715-720
DOI DOI not available
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 70, Issue: S4, Year: 2020

Request the full text from PASTIC

Keywords
Mitral valve replacement, Operative Techniques, Subvalvular Apparatus preservation
0

Citations

0

Downloads

113

Views