No Detail Found!

IMPACT OF DGs PLACEMENT ON VARIOUS FEEDERS IN DISTRIBUTION NETWORK FOR POWER LOSS REDUCTION AND VOLTAGE STABILITY

Author(s)
A. Javed Department of Electrical Engineering, NFC Institute of Engineering & Technology,Multan,Pakistan
S. Raza Department of Electrical Engineering, NFC Institute of Engineering & Technology,Multan,Pakistan
S. Iqbal Department of Electrical Engineering, Information Technology Superior College,Lahore,Pakistan
N. Nawaz Department of Electrical Engineering, NFC Institute of Engineering & Technology,Multan,Pakistan
A. Javaid Department of Electrical Engineering, NFC Institute of Engineering & Technology,Multan,Pakistan
W.Q. Awan Department of Electrical Engineering, NFC Institute of Engineering & Technology,Multan,Pakistan
Abstract
Nowadays, with the growing demand of electricity, the grid integration of renewable energy sources (RES) is highly required to reduce the dependency on fossil fuels, which will help to diminish the gas emissions and the level of carbon impression in power generation. The dependency on renewable energy resources is environment friendly for energy production therefore, the inverter-based photovoltaic (PV) generators are taken into deliberation as one of the reliable solutions, which is pollution free and effectively introduced to residential locations. The size, location and type of integrated DGs influences the performance and behavior of the system. The optimal allocation of distributed generators (DGs) has significantly impact on voltage profile and power loss of the grid due to load flow changes in the distribution network. In power system, technical and economical index divulges to the energy loss rate. This paper presents the optimal allocation of DGs at different locations by applying “Radial load-flow analysis” algorithm which will analyze the active power flow for low loss feeder and high loss feeder in MEPCO radial distribution network. Also, impact on voltage stability and power loss reduction of low loss feeder and high loss feeder by varying the DG's positions at various points in all respect of the feeder are examined. Along with this, cost of electricity and energy losses (KWH) additionally examine in this study. SYNERGEE (5.0) Electric GIS-mapping based software is used for the Simulation of this study.
Publication Details
Page(s) 84-90
DOI DOI not available
Published Journal: Pakistan Journal of Science, Volume: 71, Issue: 4S, Year: 2019

Request the full text from PASTIC

Keywords
optimization, power losses, Units consumption, Voltage drops, Distributed generator