Pakistan Science Abstracts
Choose Theme
1
2
3
4
Theme 1
— Green & Gold
Print
Save as PDF
Export BibTeX
Close
No Detail Found!
Home
›
Journal of Pakistan Medical Association
Comparison of Serum Levels of Cystatin-c and Traditional Renal Biomarkers for the Early Detection of Pre-hypertensive Nephropathy.
Author(s)
Usman Wali
Department of Medical Sciences, Assiniboine Community College,Canada
Muhammad Mazhar Hussain
Fazaia Medical College, Air University,Islamabad,
Nadia Wali
Akhtar Saeed Medical and Dental College,Lahore,Pakistan
Amina Nadeem
Army Medical College, National University of Medical Sciences, Rawalpind, Pakistan
Farzana Majeed
Rawal Institute of Health Sciences, Islamabad.Pakistan
Abstract
Objective: To compare serum Cystatin-C and serum creatinine levels along with estimated glomerular filtration rate of apparently healthy people of South Asian descent with pre-hypertension to determine which is better in detecting reversible renal dysfunction. Methods: The comparative cross-sectional study was conducted at the Army Medical College, Rawalpindi, Pakistan, in 2013-14, and comprised apparently normal healthy male and female volunteers. The subjects were divided into normotensive group 1 and pre-hypertensive group 2. Serum Cystatin-C levels were measured by sandwhich enzyme-linked immunosorbent assay technique whereas serum creatinine levels were measured by Jaffe's procedure. Glomerular filtration rate estimation was done by using standard equations. SPSS 20 was used for data analysis. Results: Of the 78 subjects, 39(50%) were in normotensive group 1 and 39(50%) in the pre-hypertensive group 2. The mean age was 38.74 ± 5.71 years in group 1 and 38.07 ± 3.84 years in group 2. Serum Cystatin-C levels were higher in group 2 than in group 1(p= 0.0001), whereas serum creatinine levels manifested no statistical difference between the groups (p=0.106). Estimated glomerular filtration rate based on Cystatin-C significantly decreased in group 2 than in group 1 (p=0.0001). Serum Cystatin-C displayed a significant positive correlation and estimated glomerular filtration rate based on Cystatin-C negative correlation with the rising blood pressure values (p=0.0001).Serum Cystatin-C reflected a very high sensitivity and specificity at a cutoff value of 0.77 mg/l compared to serum creatinine. Conclusion: Serum Cystatin-C and Estimated glomerular filtration based on rate Cystatin-C appeared to be better renal biomarkers in the detection of pre-hypertensive nephropathy.
Publication Details
Page(s)
313-319
DOI
DOI not available
Published
Journal: Journal of Pakistan Medical Association, Volume: 69, Issue: 3, Year: 2019
Request the full text from PASTIC
Keywords
Hypertension, Body Mass Index, Cockcroft-Gault, Glomerular filtration rate, Pre-hypertension, Creatinine, Nephropathy, Inulin clearance. (JPMA 69: 313, 2019), Arteriosclerosis
More from
Journal of Pakistan Medical Association
Gender Comparisons and Prevalence of Child Abuse and Post-traumatic Stress Disorder Symptoms in Adolescents.
A comparison of the Effects on Postoperative Bleeding of the Intra-articular Application of Tranexamic Acid and Adrenalin in Total Knee Arthroplasty.
Impact of Metabolic Syndrome on Nutrients Intakes among Saudi Females.
Assessing Reliability and Validity of Revised Biggs Two-factor Study Process Questionnaire to Measure Learning Approaches among Undergraduate Medical Students in Lahore, Pakistan.
Effect of L-carnitine and Conjugated Linoleic Acid Supplements on Haemoglobin Levels and Haptoglobin Genotype in Chronic Kidney Disease.
0
Citations
0
Downloads
68
Views