Silica fume concrete in flexure.

Author(s)
Ghous Bux Khaskheli Department of Civil Engineering, Mehran University of Engineering & Technology, Jamhsoro, Pakistan
Aneel Kumar Department of Civil Engineering, Mehran University of Engineering & Technology, Jamhsoro, Pakistan
Abdul Latif Sanjrani Department of Civil Engineering, Mehran University of Engineering & Technology, Jamhsoro, Pakistan
Abstract
This research is aimed to investigate the influence of SF (Silica Fume) on flexural strength of plain concrete. In total, 24 plain concrete beams were manufactured. 8 beams were manufactured with normal concrete with 1:2:4 ratio. In other 8 beams 7.5% of cement content were replaced with SF and in the other 8, 8.5% of cement content were replaced with SF. The beams were cast with 4 different w/b (water binder ratio) viz.0.40.0.45, 0.50 and 0.55 (2 beams for each combination). Flexural strength of the plain concrete beams was determined at 7 and 28 days curing age. Results show that replacement of 7.5% and 8.5% of cement with SF can increase flexural strength of concrete than that of normal concrete by 3-67%. The influence of SF increased with age of concrete. The replacement of cement with 7.5% SF in concrete can give better flexural strength than that of concrete in which 8.5% of cement is replaced with SF.
Publication Details
Page(s) 499-506
DOI DOI not available
Published Journal: Mehran University Research Journal of Engineering and Technology, Volume: 29, Issue: 3, Year: 2010