No Detail Found!

Screening Thresholds for the Corneal Tomography in a Myopic Pakistani Population.

Author(s)
Sadia Humayun Department of Refractive Surgery, Armed Forces Institute of Ophthalmology (AFIO), National University of Medical Sciences, Rawalpindi, Pakistan
Aisha Fawad Department of Eye, Combined Military Hospital, Armed Forces Postgraduate Medical Institute, Rawalpindi, Pakistan
Quratulain Humayun Department of Epidemiology, Women and Children's Hospital of Buffalo, New York, USA
Sabahat Arzoo Department of Refractive Surgery, Armed Forces Institute of Ophthalmology (AFIO), National University of Medical Sciences, Rawalpindi, Pakistan
Mazhar Ishaq Department of Refractive Surgery, Armed Forces Institute of Ophthalmology (AFIO), National University of Medical Sciences, Rawalpindi, Pakistan
Abstract
Objective: To evaluate key corneal tomography parameters for screening refractive surgery patients in Pakistani population. Study Design: Cross-sectional, observation study. Place and Duration of Study: Armed Forces Institute of Ophthalmology AFIO, National University of Medical Sciences, Rawalpindi, Pakistan, from August 2013 to December 2016. Methodology: Myopic patients were evaluated by two separate observers on Allegro OculyzerII (Wavelight) for normal ocular examination. A total of 20 tomographic parameters, used for pre-refractive surgical evaluation, were included. Normality of data was evaluated using Kolmogorov-Smirnov test. Results for outliers were displayed as 2.5%, 5%, 95% and 97.5% percentiles. Results: The sample of 451 patients (895 eyes), comprised of 61% (n=277) females and 39% (n=174) males (39%). The mean age was 26 +6.4 years (range of 18-62 years, M=F). Normal mean anterior segment values included; flat simulated keratometry (K1) 42.9 ±1.44 diopters (D), steep K2 43.9 ±1.52 D, K mean 43.4 ±1.43 D, K maximum 44.6 ±1.56 D, astigmatism -0.96 ±0.97 D, anterior chamber depth (ACD) 3.19 ±0.28 mm, front elevation at the thinnest point 4.11 ±2.44 um, and that at the back was 7.56 ±4.52 um progression index (PI) maximum 1.14 ±0.17, Ambrosio relational thickness maximum (ART max) 487.5 ±89.0 and pachymetry at thinnest point 542.2 ± 31.1 um. Conclusion: The study demonstrates key corneal tomography parameters, which can be useful for screening refractive surgery patients in Pakistani population.
Publication Details
Page(s) 128-132
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 29, Issue: 2, Year: 2019

Request the full text from PASTIC

References
AmbrósioR,BelinMW, 2010.Imaging of the cornea: Topography vs tomography,J Refract Surg 26 847 -9
OlsenT,CorydonL,GimbelH, 1995.Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm,J Cataract Refract Surg 21 313 -9
TurnerSJ,LeeEJ,HuV,HollickEJ, 2007.Scheimpflug imaging to determine intraocular lens power in vivo,J Cataract Refract Surg 33 1041 -4
De SanctisU,LoiaconoC,RichiardiL,TurcoD,MutaniB,GrignoloFM, 2008.Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus/subclinical keratoconus,Ophthalmology 115 1534 -9
WheeldonCE,HaddenOB,NiedererRL,McGheeCN, 2008.Presumed late diffuse lamellar keratitis progressing to interface fluid syndrome,J Cataract Refract Surg 34 322 -6
AmbrósioR,ValbonBF,Faria-CorreiaF,RamosI,LuzA, 2013.Scheimpflug imaging for laser refractive surgery,Curr Opin Ophthalmol 24 310 -20
ChenD,LamAK, 2009.Reliability and repeatability of the Pentacam on corneal curvatures,Clin Exp Optom 92 110 -8
FengMT,KimJT,AmbrósioR,BelinMW,GrewalSPS,YanW, 2012.International values of central pachymetry in normal subjects by rotating scheimpflug camera,Asia Pac J Ophthalmol (Phila) 1 13 -8
KhachikianSS,BelinMW, 2009.Posterior elevation in keratoconus,Ophthalmology 116 816 -
2016.Guidance for industry. Collection of race and ethnicity data in clinical trials. U.S. Department of health and human services, food,Document issued on October 26 -
CummingAB,MascharkaN., 2010.Outcomes after topography based LASIK and LASEK with the wavelight oculyzer and topolyzer platforms,J Refract Surgery 26 478 -85
AmbrosioR,CaiadoAL,GuerraFP,LouzadaR,RoyAS,LuzA, 2011.Novel pachymetric parameters based on corneal tomography for diagnosing keratoconus,J Refract Surg 27 753 -8
GilaniF,CorteseM,AmbrósioRR,LopesB,RamosI,HarveyEM, 2013.Comprehensive anterior segment normal values generated by rotating Scheimpflug tomography,J Cataract Refract Surg 39 1707 -12
MurataC,MallmannF,YamazakiE,CamposM. [, 2007.Anterior ocular segment study with the Scheimpflug rotational camera in refractive surgery candidates],Arq Bras Oftalmol 70 619 -24
HashemiM,FalavarjaniKG,AghaiGH,AghdamKA,GordizA, 2013.Anterior segment study with the Pentacam Scheimpflug camera in refractive surgery candidates,Middle East Afr J Ophthalmol 20 212 -6
FengMT,BelinMW,AmbrósioR,GrewalSPS,YanW,ShaheenMS, 2011.International values of corneal elevation in normal subjects by rotating Scheimpflug camera,J Cataract Refract Surg 37 1817 -21
0

Citations

0

Downloads

32

Views