No Detail Found!

Agreement Between Keratometric Readings by Verion Image Guided System, Galilei G4 and Pentacam.

Author(s)
Asad Habib Ophthalmology, Armed Forces Institute of Ophthalmology (AFIO), Rawalpindi, Pakistan
Muhammad Saim Khan Ophthalmology, Armed Forces Institute of Ophthalmology (AFIO), Rawalpindi, Pakistan
Mazhar Ishaq Armed Forces Institute of Ophthalmology (AFIO), National University of Medical Sciences (NUMS), Rawalpindi, Pakistan
Muhammad Amer Yaqub Armed Forces Institute of Ophthalmology (AFIO), National University of Medical Sciences (NUMS), Rawalpindi, Pakistan
Abstract
Objective: To study Agreement between Keratometric readings by VERION image guided System, Galilei G4 and Pentacam. Methods: The quasi experimental study was conducted at Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan from August 2016 to December 2016. Twenty five patients fulfilling the inclusion criteria participated in the study. All Patients were subjected to Keratometric assessment using Galilei G4 Dual Scheimpflug analyzer (Ziemer, Switzerland), Wavelight Oculyzer II (Pentacam, Germany) and Verion image guided system (Alcon). Steep and flat meridian and diopter of astigmatism by three systems were recorded and endorsed. All readings were taken by the same observer. Statistical Program for Social Sciences (SPSS) version 22.0 was used for statistical analysis. Results analyzed for significance by t-tests and Interclass correlation analysis. In t tests, P values of 0.7 was considered acceptable. Results: Fifty eyes of twenty-five patients (22 male, 28 female) with mean age of 29.50 ± 3.46 years were studied. Flat K, steep K and dioptric power of astigmatism were measured with verion, pentacam and Galilei G4. Interclass correlation analysis showed agreement between individual variables measured by the three devices, while one sample t test showed no significant difference between dioptric power of astigmatism between Verion-Pentacam and Verion- Galilei group. (p 0.178 for former and 0.622 for later group). Conclusion: Verion image guided system is comparable to other instruments used currently for keratometry. Verion can be interchangeably used with Pentacam and Galilee G4 in assessing corneal astigmatism.
Publication Details
Page(s) 740-743
DOI DOI not available
Published Journal: Pakistan Journal of Medical Sciences, Volume: 34, Issue: 3, Year: 2018

Request the full text from PASTIC

References
LeeAC,QaziMA,PeposeJS, 2008.Biometry and intraocular lens power calculation,Curr Opin Ophthalmol 10 13 -17
TomidokoroA,OshikaT,AmanoS,HigakiS,MaedaN, 2000.Changes in anterior and posterior corneal curvatures in keratoconus,Ophthalmology 107 1328 -1332
JinabhaiA,RadhakrishnanH,O'Donnell C., 2011.Pellucid corneal marginal degeneration: A review,Cont Lens Anterior Eye 34 56 -63
ElhofiAH,HelalyHA, 2015.Comparison between digital and manual marking for toric intraocular lenses: A randomized trial,doi 10 94 -
ChenD,LamAK, 2008.Reliability and repeatability of the Pentacam on corneal curvatures,Clin Exp Optom 00336 0938 -118
McAlindenC,KhadkaJ,PesudovsK., 2011.A Comprehensive Evaluation of the Precision (Repeatability and Reproducibility) of the Oculus Pentacam HR,Invest Ophthalmol Vis Sci 52 7093 -7737
ShankarH,TaranathD,SanthirathelaganCT,PesudovsK., 2007.Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements,J Cataract Refract Surg 09 103 -113
WangQ,SaviniG,HofferKJ,XuZ,FengY,WenD, 2012.A comprehensive assessment of the precision and agreement of anterior corneal power measurements obtained using 8 different devices,PLoS One 0045607 -
HuynhSC,MaiTQ,KifleyA,WangJJ,RoseKA, 2006.An evaluation of keratometry in 6-yearold children,Cornea 0000214203 383 -387
LauschkeJL,LawlessM,SuttonG,RobertsTV,HodgeC, 2016.Assessment of corneal curvature using verion optical imaging system: a comparative study,Clin Exp Ophthalmol 44 369 -376
ChoiJA,KimMS, 2012.Progression of Keratoconus by longitudinal assessment with corneal topography,Invest Ophthalmol Vis Sci 53 8118 -935
NorrbyS., 2007.Sources of error in intraocular lens power calculation,J Cataract Refract Surg 10 368 -376
LauschkeJL,LawlessM,SuttonG,RobertsTV,HodgeC, 2016.Assessment of corneal curvature using verion optical imaging system: a comparative study,Clin Exp Ophthalmol 44 369 -376
VisserN,BerendschotTT,VerbakelF,de BrabanderJ,NuijtsRM, 2012.Comparability and repeatability of corneal astigmatism measurements using different measurement technologies,J Cataract Refract Surg 05 1764 -1770
ThibosLN,HornerD., 2001.Power vector analysis of the optical outcome of refractive surgery,J Cataract Refract Surg 27 80 -85
ReadSA,CollinsMJ,IskanderDR,DavisBA, 2009.Corneal Topography with Scheimpflug imaging and videokeratography: comparative study of normal eyes,J Cataract Refract Surg 35 1072 -1081
0

Citations

0

Downloads

171

Views