New seismic parameters for building code of pakistan and their effect on existing reinforced concrete buildings: a case study

Author(s)
M. B. Sharif Department of Civil Engineering, University of Engineering & Technology (UET), Lahore, PAKISTAN
A. U. Qazi Department of Civil Engineering, University of Engineering & Technology (UET), Lahore, PAKISTAN
M. Ilyas Structural Division, National Engineering Services Pakistan (Pvt) Limited (NESPAK), Lahore, PAKISTAN
N. Mohsin Structural Division, National Engineering Services Pakistan (Pvt) Limited (NESPAK), Lahore, PAKISTAN
Abstract
The large scale devastation caused by the earthquake of October 08, 2005 in Northern Pakistan and Azad Jammu and Kashmir has raised several questions on the adequacy of the present design and construction practice in the country. Realizing the gravity of the situation, the Government of Pakistan appointed a Committee of technical experts and Government Officials to supervise and provide guidance for revision/updating of Building Code of Pakistan, to suggest modifications to the present codes of practice and to particularly incorporate the recommendations for earthquake resistant design of buildings. Therefore, It is important to check the adequacy of existing structures especially in high seismic risk zones according to revised seismic parameters. The National Insurance Complex Limited (NICL) Building, Jinnah Avenue, Blue Area Islamabad is selected for study. It was constructed in 1994. In this research seismic analysis has been performed for National Insurance Complex Limited (NICL) building. These analyses include linear static analysis, response spectrum analysis, non-linear static analysis and linear time history analysis which are performed using ETABS. Different analysis approaches have been used to carry out the lateral analysis on the basis of BCOP- 2007 and the time histroy of October 8, 2005 earthquake. The study revealed that base shear is increased by 7% due to the change in the seismic zoning for the current location of the building. It is concluded that the change in seismic zoning has not seriously threatened the stability of existing buildings. The buildings which are then designed according to some recogonized building codes when analyzed according to BCP-2007 should fall safe. However failure may be expected incase of the building is not preperly designed or poorly constructed. 
Publication Details
Page(s) 84-90
DOI DOI not available
Published Journal: Pakistan Journal of Science, Volume: 63, Issue: 2, Year: 2011

Request the full text from PASTIC

0

Citations

0

Downloads

555

Views