No Detail Found!

Annual effective dose due to residential radon exposure in the dwellings of Abbottabad.

Author(s)
S. U. Rahman Nuclear Medicine, Oncology and Radiotherapy Institute (NORI), Islamabad, Pakistan
R. Muhammad Federal Urdu University, Islamabad, Pakistan
F. Khan COMSATS Institute of Information Technology (CIIT), Islamabad, Pakistan
M. Rafique University ofAzad Jammu and Kashmir, Muzaffarabad, Pakistan
Z. Wazir Riphah University, Islamabad, Pakistan
Abstract
A study was conducted to measure indoor radon concentrations in dwellings of the Abbottabad city. In this regard, CR-39 based radon detectors were installed in drawing rooms and bedrooms of 40 selected houses and were exposed to indoor radon for 3 months. After exposure, the CR-39 detectors were etched for 8 hrs in 6M NaOH solution at 70 C and tracks were counted under an optical microscope. The observed tracks densities were related to radon concentrations using a calibration factor of 2.7 tracks.cm-2 .h-1 /kBq.m-3 .The mean annual estimated effective dose received by the residents of the studied area was found to be 1.48 ± 0.47 mSv y-1 Comparing the current indoor radon results with the published data of international agencies, it was found that the houses surveyed in the present study were within the safe limits.
Publication Details
Page(s) 39-42
DOI DOI not available
Published Journal: Science Vision, Volume: 18, Issue: 1,2, Year: 2012

Request the full text from PASTIC

0

Citations

0

Downloads

57

Views