A novel selective absorption of SO2 from a produced stream containing SO2, CO2, N2 and steam mixture with amine solution was investigated using an absorption/stripping columns in laboratory scale. SO2 concentration, stripper temperature, gas to liquid ratio and solvent pH were considered as working parameters to investigate their effect on SO2 removal efficiency from the flue gas. According to the experiments, sulfur dioxide which was in the range of 4000 ppm to 8000 ppm in gas mixture was reduced to less than 200 ppm and 1000 ppm respectively. Furthermore the selectivity of the absorption is tested by performing an 8 days test which showed the selectivity of more than 99.8 %. Observation showed the effectiveness of parameters ranked to the least as pH, stripper temperature, inlet SO2 concentration and gas to the liquid ratio.