No Detail Found!

Canine Retraction using a Closed Nickel Titanium Coil Spring and An Elastic Module.

Author(s)
Zahra Khalid Department of Orthodontics, Armed Forces Institute of Dentistry, Rawalpind, Pakistan
Azhar Ali Bangash Department of Orthodontics, Armed Forces Institute of Dentistry, Rawalpind, Pakistan
Ayesha Anwar Department of Orthodontics, Armed Forces Institute of Dentistry, Rawalpind, Pakistan
Hajra Pasha Department of Orthodontics, Armed Forces Institute of Dentistry, Rawalpind, Pakistan
Erum Amin Department of Orthodontics, Armed Forces Institute of Dentistry, Rawalpind, Pakistan
Abstract
Objective: To compare the mean change of tooth movement in canine retraction between elastic module and Ni Ti coil spring. Study Design: Comparative study. Place and Duration of Study: Orthodontics Department, Armed Forces Institute of Dentistry, Rawalpindi, from May 2015 to January 2016. Methodology: Thirty-two patients were inducted. After alignment and extraction of maxillary first premolars, canine retraction was started with closed Ni Ti coil spring on one side of the maxillary arch and with active tie back on the other side. The distance between the lateral incisor and the canine was measured on both sides before starting canine retraction. The same measurements were recorded after four weeks of retraction. The difference between pre and post retraction measurements was recorded. The difference in the rate of canine retraction between both modalities was compared using independent sample t-test. Results: The study included 56% females and 43% males. The mean rate of tooth movement in Ni Ti coil group and in the elastomeric module group was 1.1 mm and 0.7 mm in one month, respectively (p=0.05). Conclusion: The rate of tooth movement is more rapid with Ni Ti coil spring than with the elastomeric module.
Publication Details
Page(s) 695-698
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 28, Issue: 9, Year: 2018

Request the full text from PASTIC

References
Nanda RUribe F., 2009.Temporary anchorage devices in orthodontics,St. Louis -
DanaeiSM,OshaghM,KhozaiA, 2013.Effect of recycling and autoclave sterilization on the unloading forces of NiTi closedcoil springs: An in vitro study,J Dent (Shiraz) 14 184 -90
AwniKM, 2012.Comparison between laceback and tieback in sliding mechanics (an in vitro study),Al-Rafidain Dent J 12 148 -52
GjessingP, 1985.Biomechanical design and clinical evaluation of a new canine-retraction spring,Am J Orthod 87 353 -62
HayashiK., 2004.Comparison of maxillary canine retraction with sliding mechanics and a retraction spring: a three-dimensional analysis based on a midpalatal orthodontic implant,The Eur J Orthod 26 585 -9
KanuruR,KolasaniB,NarayanaV,IndukuriR,AzaneenM, 2014.Comparison of canine retraction by in vivo method using four brands of elastomeric power chain,J Int Soc Prevent Communit Dent 4 32 -
UsmaniT,O'BrienKD,WorthingtonHV,DerwentS,FoxD,HarrisonS, 2002.A randomized clinical trial to compare the effectiveness of canine lacebacks with reference to canine tip,J Orthod 29 281 -6
SamuelsR,OrthM,RudgeS,Mair L, 1993.A comparison of the rate of space closure using a nickel-titanium spring and an elastic module: A clinical study,Am J Orthod Dentofacial Orthop 103 464 -7
SueriM,TurkT., 2006.Effectiveness of laceback ligatures on maxillary canine retraction,Angle Orthod 76 1010 -4
BennettJC,McLaughlinRP, 1990.Controlled space closure with a preadjusted appliance system,J Clin Orthod 24 251 -60
SowmyaKS,ChandralekhaB,UmaHL,KumariS,PadminiMN, 2011.-active-tie-backs-and-nickel titaniumcoil-springs-in-canine-retraction-a-clinical-study-with-the-mbtsystem,Orthodontic Cyber J -
RenY,MalthaJ,HofM,Kuijpers-JagtmanA, 2004.Optimum force magnitude for orthodontic tooth movement: a mathematic model,Am J Orthod Dentofacial Orthop 125 71 -7
MaganziniA,WongA,AhmedM., 2010.Forces of various nickel titanium closed coil springs,Angle Orthod 80 182 -7
BuchmannN,SennC,BallJ,BrauchliL, 2012.Influence of initial strain on the force decay of currently available elastic chains over time,Angle Orthod 82 529 -35
ZieglerP,IngervallB., 1989.A clinical study of maxillary canine retraction with a retraction spring and with sliding mechanics,Am J Orthod Dentofacial Orthop 95 99 -106
KulshresthaR,TandonR, 2015.Canine retraction: A systematic review of different methods used,J Orthod Sci 4 1 -
QuinnR, 1985.A reassessment of force magnitude in orthodontics,Am J Orthod 88 252 -60
PletcherEC, 1959.Simplified management of space closure,Am J Orthod 45 278 -86
DholakiaK,BhatS., 2012.Clinical efficiency of nonconventional elastomeric ligatures in the canine retraction phase of preadjusted edgewise appliance therapy: An in-vivo study,Am J Orthod Dentofacial Orthop 141 715 -22
0

Citations

0

Downloads

121

Views