Abstract
Objective: To evaluate the success of ultrasound in post-excision specimen visualization, and negative predictive value of ultrasound for estimation of tumor-free margins using histopathology as the gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: The Aga Khan University Hospital, Karachi, Pakistan, from May 2010 till January 2013. Methodology: Sonography of all breast nodules was done before and after exicision by two female radiologists with at least five years clinical experience. All surgeries were performed by the same referring breast surgeons. All nodules were non-palpable and had histopathology as well as specimen sonography performed at AKUH. Subjects were excluded, if histopathology was not available, post-procedure sonogram not done or done in another hospital and nodules that were not seen on ultrasound. After needle localization in 47 patients using ultrasound and in 7 patients using mammogram was done, sonogram was conducted in all 54 lesions. These were then assessed by ultrasound for detection of lesion and tumor-free margins in malignant lesion. Post-excision ultrasound was performed for the evaluation of lesion whether visualized or absent with localizing needle in situ, lesion dimensions, depth measurement between the superior margin of the lesion and its edge. Results: All 54 lesions were present on post-exicison scan, out of which 28 were documented as malignant and 26 as benign. Ultrasound declared all specimens as tumor-free. On histopathology, two lesions were documented as having tumor-positive margins and were proven to be invasive lobular carcinoma. Therefore, the negative predictive value of the specimen sonography for margin detection was 26/28 (92.8%). Conclusion: Ultrasound of the excised breast tumor specimen is a simple and reliable technique for confirmation of the tumor-free margins in non-palpable breast lesions.
Publication Details
Page(s) 747-750
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 27, Issue: 12, Year: 2017

Request the full text from PASTIC

Keywords
Breast. Tumors. Specimen sonography. Ultrasound (US). Negative predictive value.
References
HomerMJ, 1998.Radiography of the surgical breast biopsy specimen,AJR 171 1197 -9
D'Orsi,CJ, 1995.Management of the breast specimen,Radiology 194 297 -302
FornageBD,RossMI,SingletarySE,PaulusDD, 1994.Localization of impalpable breast masses: value of sonography in the operating room and scanning of excised specimens,AJR 163 569 -73
StaradubVL,RademakerAW,MorrowM., 2003.Factors influencing outcomes for breast conservation therapy of mammographically detected malignancies,J Am Coll Surg 196 518 -24
JackmanRJ,MarzoniFA, 1997.Needle-localized breast biopsy: why do we fail?,Radiology 204 677 -84
HomerMJ,SmithTJ,SafaiiH, 1992.Prebiopsy needle localization: methods, problems, and expected results,Radiol Clin North Am 30 139 -53
LibermanL,GoodstineSL,DershawDD, 2002.One operation after percutaneous diagnosis of nonpalpable breast cancer: frequency and associated factors,AJR 178 673 -79
MargolisNE,MorleyC,LotfiP,ShaylorSD,PalestrantS,MoyL, 2014.Update on imaging of the postsurgical breast,Radiographics 34 642 -60
BrennerRJ,BassettLW,FajardoLL, 2001.Stereotactic core-needle breast biopsy: a multi-institutional prospective trial,Radiology 218 866 -72
Guerrieri-GonzagaA,BotteriE,RotmenszN,BassiF,IntraM,SerranoD, 2009.Ductal intraepithelial neoplasia: postsurgical outcome for 1,267 women cared for in one single institution over 10 years,Oncologist 14 201 -12
PiperM,PeledAW,PriceER,FosterRD,EssermanLJ,SbitanyH, 2015.Mammographic changes after oncoplastic reduction mammoplasty,Ann Plast Surg -
WhippEC,HalliwellM., 2008.Magnetic resonance imaging appearances in the postoperative breast: the clinical target volume-tumor and its relationship to the chest wall,Int J Radiat Oncol Biol Phys 72 49 -57
HiroseM,HashizumeT,SeinoN,KubotaH,NobusawaH,GokanT., 2007.Atlas of breast magnetic resonance imaging,Curr Probl Diagn Radiol 36 51 -65
LeoniM,SadacharanR,LouisD,FalciniF,RabinowitzC,CisbaniL, 2013.Variation among local health units in follow-up care of breast cancer patients in Emilia-Romagna, Italy,Tumori 99 30 -4
OlsonJA,MorrisEA, 2000.Magnetic resonance imaging facilitates breast conservation for occult breast cancer,Ann Surg Oncol 7 411 -5
ViciniFA,GoldsteinNS,KestinLL, 1999.Pathologic and technical considerations in the treatment of ductal carcinoma in situ of the breast with lumpectomy and radiation therapy,Ann Oncol 10 883 -90
StargenED,O'Neil TP, 1998.Breast ultrasound,Surg Clin North Am 78 219 -36
NewmanPG,RozyckiGS, 1998.The history of ultrasound,Surg Clin North Am 78 179 -96
Georgian-SmithD,TaylorKJW,MadjarH, 2000.Sonography of palpable breast cancer,J Clin Ultrasound 28 211 -6