No Detail Found!

Predictability of Intrapartum Cardiotocography with Meconium Stained Liquor and its Correlation with Perinatal Outcome.

Author(s)
Ayesha Husain Obstetrics and Gynecology Department, DarulSehat Hospital, Karachi, Pakistan
Aliya Naseem Obstetrics and Gynecology Department, DarulSehat Hospital, Karachi, Pakistan
Sagheera Anjum Obstetrics and Gynecology Department, DarulSehat Hospital, Karachi, Pakistan
Sajida Imran Obstetrics and Gynecology Department, DarulSehat Hospital, Karachi, Pakistan
Muhammad Arifuzzaman Dow Institute of Radiology, Karachi, Pakistan
Syed Omair Adil Department of Research, Dow University of Health Sciences, Karachi, Pakistan
Abstract
Objective: To determine the relationship between the colour of liquor and the trace of cardiotocography to see whether it is reactive or non-reactive. Methods: This cross-sectional study was conducted at Obstetrics and Gynaecology department, Dar-ul-Sehat Hospital, Karachi from June 2015 to March 2016, and comprised women in labour who delivered singleton babies and had >37 weeks of gestation. Intrapartum monitoring by cardiotocography was conducted. The status of the amniotic membranes, colour and amount of liquor observed were recorded. Cardiotocography was performed for 30 minutes in the left lateral position on admission as well as a monitoring tool in labour at an interval of less than 4 hours. Foetal heart transducer and uterine pressure transducers were applied and the readings were recorded. SPSS 21 was used for statistical analysis. Results: Of the total 200 subjects, 183(91.5%) were reactive and 17(8.5%) were non-reactive women. Overall mean age was 27.39±4.40 years. Most commonly noted risk factor were post-date 53(26.5%), anaemia 35(17.5%), premature rupture of membranes 28(14%) and pregnancy-induced hypertension 10(5%). Insignificant difference was observed in between Cardiotocography findings and risk factors of the women (p>0.05). Conclusion: Significant change was seen in cardiotocography of clear liquor which needs more evaluation to rule out ongoing hypoxia.
Publication Details
Page(s) 1014-1018
DOI DOI not available
Published Journal: Journal of Pakistan Medical Association, Volume: 68, Issue: 7, Year: 2018

Request the full text from PASTIC

References
KumariR,SrichandP,DevrajaniBR,ShahSZA,DevrajaniT,BibiI, 2012.Foetal outcome in patients with Meconium Stained Liquor,J Pak Med Assoc 62 474 -6
Tayade S., 2012.The significance of meconium stained amniotic fluid - a cross sectional study in a rural setup,IJBAR 03 861 -6
MundhraR,AgarwalM., 2013.Fetal outcome in meconium stained deliveries,J ClinDiagn Res 7 2874 -6
HofmeyrGJ,HawsRA,BergströmS,LeeAC,OkongP,DarmstadtGL, 2009.Obstetric care in low resource settings: What, who, and how to overcome challenges to scale up?,Int J GynaecolObstet 107 S44 -
KhalifaAK, 2015.Management of neonatal hazards in intensive care units: a review,Int J Sci Reports 1 3 -21
AldirevieZ,DevaneD,GyteGM, 2006.Continuous cardiotocographyas a form of electronic fetal monitoring for fetal assessment during labour,Cochrane Database Syst Rev 3 CD006066 -
BogdanovicG,BabovicA,RizvanovicM,LjucaD,GrgicG,Djuranovic-MilicJ, 2014.Cardiotocography in the Prognosis of Perinatal Outcome,Med Arch 68 102 -5
SupriyaK,ThungaS,SinghP., 2014.Clinical study of meconium stained amniotic fluid,Int J Biomed Adv Res 5 612 -4
EriksenN,HostetterM,ParisiV, 1994.Prophylactic amnioinfusion in pregnancies complicated by thick meconium,Am J ObstetGynecol 171 1026 -30
AliL,MushtaqR,AhmedN., 2014.Frequency of pathological CTG in low risk women and its outcomes,Pak J Surg 30 340 -45
BracciR,PerroneS,BuonocoreG., 2006.The timing of neonatal brain damage,Neonatology 90 145 -55
PatilKP,SwamyMK,SamathaK., 2006.A one year cross sectional study of management practices of meconium stained amniotic fluid and perinatal outcome,ObstetGynecol India 56 128 -30
NaveenS,KumarSV,RituS,KushiaP, 2006.Predictors of meconium stained amniotic fluid: a possible strategy to reduce neonatal morbidity and mortality,J ObstetGynecol India 56 514 -7
MundhraR,AgarwalM., 2013.Fetal outcome in meconium stained deliveries,J Clin Diagn Res 7 2874 -6
SaundersK., 2002.Should we worry about meconium? A controlled study of neonatal outcome,Trop Doct 32 7 -10
NaveenS,KumarSV,RituS,KushiaP, 2006.Predictors of meconium stained amniotic fluid: a possible strategy to reduce neonatal morbidity and mortality,J ObstetGynecol India 56 514 -7
MundhraR,AgarwalM., 2013.Fetal outcome in meconium stained deliveries,J Clin Diagn Res 7 2874 -6
SiriwachirachaiT,SangkomkamhangUS,LumbiganonP,LaopaiboonM, 2014.Antibiotics for meconium-stained amniotic fluid in labour for preventing maternal and neonatal infections,Cochrane Database Syst Rev 11 CD007772 -
SupriyaK,ThungaS,SinghP., 2014.Clinical study of meconium stained amniotic fluid,Int J Biomed Adv Res 5 612 -4
IntrapartumAmnioinfusion in Meconium-Stained Liquor : A CaseControl,Study. J Obstet Gynaecol India, 2013., 63 164 -7
0

Citations

0

Downloads

163

Views