No Detail Found!

Assessment of Contamination on Sterilised Dental Burs after Being Subjected to Various Pre-cleaning Methods.

Author(s)
Meisha Gul Section of Operative Dentistry, Department of Surgery, Aga Khan University, Karachi, Pakistan
Robia Ghafoor Section of Operative Dentistry, Department of Surgery, Aga Khan University, Karachi, Pakistan
Surhan Aziz Section of Operative Dentistry, Department of Surgery, Aga Khan University, Karachi, Pakistan
Farhan Raza Khan Section of Operative Dentistry, Department of Surgery, Aga Khan University, Karachi, Pakistan
Abstract
Objective: To determine the effectiveness of different pre-cleaning methods by determining frequency and site of contamination on the sterilised dental burs using Phloxine B dye. Method: The in-vitro experimental study was conducted from June to August 2017 at dental clinics of Aga Khan University Hospital Karachi. Diamond dental burs were selected and divided into two control and four test groups. The two control groups were classified as Negative (new burs) and Positive (used contaminated). The four test groups were classified as Manual (Group-1), Ultrasonic (Group-2), Manual + Enzyme (Group-3) and Manual + Ultrasonic (Group-4). Phloxine B dye was used to determine the contamination. The images of the burs were taken and enlarged at 15X before subjected to visual assessment. Association between contamination and pre-cleaning methods were determined. Data was analysed using SPSS version 22. Results: A total of 210 burs were selected for the study which were divided in 6 groups of 35(16.66%) each. One (2.8%) bur in negative control group and all burs in positive control group showed contamination. In test groups, 27(77.1%), 29(82.8%), 27(77.1%) and 24(68.5%) burs showed contamination in groups 1, 2, 3 and 4, respectively. There was no association between type of pre-cleaning method with the frequency of contamination (p =0.57). The head of bur was the most frequently contaminated site (p < 0.003). Conclusions: None of the pre-cleaning method was found to be effective. Head of bur was the most frequently contaminated site.
Publication Details
Page(s) 1188-1192
DOI DOI not available
Published Journal: Journal of Pakistan Medical Association, Volume: 68, Issue: 8, Year: 2018

Request the full text from PASTIC

References
SajjanshettyS,HugarD,HugarS,RanjanS,KadaniM., 2014.Decontamination Methods Used for Dental Burs-A Comparative Study,J Clin Diagn Res 8 39 -41
BritishDental, 2003.Association. Infection Control in Dentistry, A12 Advice sheet, -
GargY,BhaskarDJ,AgaliCR,PuniaH,GargK,DalaiDR, 2015.Infection Control in Dentistry: Need for a Better Practice,Arch of Dent and Med Res 1 19 -31
KumarKV,KumarKK,SupreethaS,RaghuK,VeerabhadrappaAC,DeepthiS., 2015.Pathological evaluation for sterilisation of routinely used prosthodontic and endodontic instruments,J Int Soc Prev Community Dent 5 232 -6
VasseyM,BudgeC,PoolmanT,JonesP,PerrettD,NayuniN, 2011.A quantitative assessment of residual protein levels on dental instruments reprocessed by manual, ultrasonic and automated cleaning methods,Br Dent J 210 E14 -
WhitworthCL,MartinMV,GallagherM,Worthington HV, 2004.A comparison of decontamination methods used for dental burs,Br Dent J 197 635 -40
HarknessN,DaviesEH, 1983.The cleaning of dental diamond burs,Br Dent J 154 42 -5
NosouhianS,BajoghliF,SabouhiM,BaratiM,DavoudiA,SharifipourM., 2015.Efficacy of different techniques for removing debris from endodontic files prior to sterilisation,J Int Oral Health 7 42 -6
WadhwaniC,SchoenbaumTR,AudiaF,ChungKH, 2016.In vitro study of the contamination remaining on used healing abutments after cleaning and sterilising in dental practice,Clin Implant Dent Relat Res 18 1069 -74
Rasooly R. PhloxineB, 2007.a versatile bacterial stain,FEMS Immunol Med Microbiol 49 261 -5
MorrisonA,ConrodS., 2010.Dental burs and endodontic files: are routine sterilisation procedures effective,Tex Dent J 127 295 -300
SagripantiJL,BonifacinoA, 1996.Comparative sporicidal effect of liquid chemical germicides on three medical devices contaminated with spores of Bacillus subtilis,Am J Infect Control 24 364 -71
LeontiouAP,CooganMM,AspinallS., 1999.Disinfection of dental diamond burs contaminated with hepatitis B virus,J Prosthet Dent 82 332 -5
LwangaSK,LemeshowS., 1991.Sample size determination in health studies: a practical manual, -
HoggNJ,MorrisonAD, 2005.Resterilisation of instruments used in a hospital-based oral and maxillofacial surgery clinic,J Can Dent Assoc 71 179 -82
EngelhardtJP,GrünL,DahlHJ, 1984.Factors affecting sterilisation in glass bead sterilisers,J Endod 10 465 -70
FerrariPH,CaiS,BombanaAC, 2005.Effect of endodontic procedures on enterococci, enteric bacteria and yeasts in primary endodontic infections,Int Endod J 38 372 -80
PattersonCJ,McLundieAC,MackayAM, 1988.The effect of ultrasonic cleansing and autoclaving on tungsten carbide burs,Br Dent J 164 113 -5
LoweAH,BurkeFJ,McHughS,BaggJ., 2002.A survey of the use of matrix bands and their decontamination in general dental practice,Br Dent J 192 40 -2
1996.Sterilisation: Part 2. Heat and chemical sterilisation,FDI World 5 13 -6
PazelliLC,FreitasAC,ItoIY,Souza-GugelminMC,MedeirosAS,Nelson-FilhoP, 2003.Prevalence of microorganisms in root canals of human deciduous teeth with necrotic pulp and chronic periapical lesions,Pesqui Odontol Bras 17 367 -71
CafrunyW,BrunickA,NelsonD,NelsonR, 1995.Effectiveness of ultrasonic cleaning of dental instruments,Am J Dent 8 152 -6
SmithA,DicksonM,AitkenJ,BaggJ, 2002.Contaminated dental instruments,J Hosp Infect 51 233 -5
WilsonAA., 1988.Council on dental materials, Instruments, and equipment, Council on dental practice and Council of dental therapist. Infection control recommendations for the dental office and the dental laboratory,J Am Dent Assoc 116 241 -8
VillasenorA,HillSD,SealeNS, 1992.Comparison of two ultrasonic cleaning units for deterioration of cutting edges and debris removal on dental burs,Pediatr Dent 14 326 -30
BentleyEM, 1994.The value of ultrasonic cleaners in dental practice,Br Dent J 177 53 -6
0

Citations

0

Downloads

122

Views