No Detail Found!

Comparison of Clinical Efficacy of Right Versus Left Sided Double Lumen Endobronchial Tube in Conjunction with Fiberoptic Bronchoscope.

Author(s)
Ahmed Mujadid Burki Combined Military Hospital/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Saira Mahboob Combined Military Hospital/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Naseem Ahmed Combined Military Hospital/National University of Medical Sciences (NUMS) Rawalpindi, Pakistan
Abstract
Objective: We compared right and left sided double lumen endobronchial tube (DLT) regarding their clinical efficacy and safety profile in when they are used in conjunction with flexible fiberoptic bronchoscope. Study Design: Quasi experimental study. Place and Duration of Study: Anesthesiology department, Combined Military Hospital Rawalpindi for 05 months, from Apr to Aug 2017. Material and Methods: After the approval of the hospital ethical committee, 90 patients were included in our study. Auscultation was used to check proper position. A flexible fiberoptic bronchoscope was used to confirm auscultation finding. The insertion time; incidence of tube malposition (supine and lateral); intra-operative hypoxia and hypercapnia were recorded. Results: A total of 90 patients underwent various thoracic surgery procedures with one lung ventilation. After the data collection, 13 patients were excluded from final analysis. Of the 77 cases, 55 patients (group L) had placement of left sided double lumen endobronchial tube; whereas 22 patients (group R) had right sided double lumen endobronchial tube. The two groups didn't vary in their demographic profile. The insertion time was significantly longer in right DLT insertion, 296.6 ± 49.8 second versus 239 ± 33.4 second (p-value0.05) did not vary between the two groups. One patient in right DLT versus two patients in left group required return to two lung ventilation for treatment of hypoxia, p-value 0.64. Conclusion: Our study has shown that right sided double lumen endobronchial tubehad similar clinical efficacy as left double lumen endobronchial tube when they are used for fiberoptic bronchoscope.
Publication Details
Page(s) 947-952
DOI DOI not available
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 68, Issue: 4, Year: 2018

Request the full text from PASTIC

References
BrodskyJB,MarkJB, 1991.Bilateral upper lobe obstruction from a single double-lumen tube,Anesthesiology 74 1163 -4
BenumofJL,PartridgeBL,SalvatierraC,KeatingJ, 1987.Margin of safety in positioning modern double-lumen endotracheal tubes,Anesthesiology 67 729 -38
SlingerP,CamphosJH, 2010.,Miller's Anesthesia. 7th ed. Elsevier USA 1982 -2061
KarzaiW,SchwarzkopfK., 2009.Hypoxemia during one-lung ventilation: Prediction, prevention, and treatment,Anesthesiology 110 1402 -11
KazanR,BraccoD,HemmerlingTM, 2009.Reduced cerebral oxygen saturation measured by absolute cerebral oximetry during thoracic surgery correlated with postoperative complications,Br J Anaesth 103 811 -6
EhrenfeldJM,WalshJL,SandbergWS, 2008.Right- and left-sided Mallinckrodt double-lumen tubes have identical clinical performance,Anesth Analg 106 1847 -52
CheckettsMR,AlladiR,Fergusonk,handyJM,KleinAA, 2016.Recommendations for standards of monitoring during anesthesia and recovery 2015: Association of anasethetists of Great Britain and Ireland,Anesthesia 71 85 -93
SlingerPD, 1989.Fiberoptic bronchoscopic positioning of doublelumen tubes,J Cardiothorac Anesth 3 486 -96
KarzaiW,SchwarzkopfK., 2009.Hypoxemia during one-lung ventilation: Prediction, prevention, and treatment,Anesthesiology 110 1402 -11
PurohitA,BhargavaS,MangalV,ParasharVK, 2015.Lung isolation, one lung ventilation and hypoxemia during lung isolation,Indian J Anaesth 59 606 -17
NgA,SwanevelderJ, 2010.Hypoxaemia during one-lung anaesthesia,Contin Educ Anaesth Crit Care Pain 10 117 -22
RezeH,LafargueM,OuattaraA, 2011.Case scenario: Management of Intraoperative Hypoxemia during one lung ventilation,Anesthesiology 114 167 -74
SlingerP,CamphosJH, 2010.,Miller's Anesthesia. 7th ed. Elsevier USA 1982 -2061
EhrenfeldJM,MulvoyW, 2010.Performace comparison of right and left sided double lumen tubes among infrequent users,J Cardiothorac Vasc Anesth 24 598 -601
CamposJH,MassaFC,KerstineKH, 2000.The incidence of right upper lobe collapse when comparing a right sided double lumen tube versus a modified left double lumen tube for left sided thoracic surgery,Anesth Analg 90 535 -40
KaplanT,EkmekciP,KazbekBK,OganN,AlhanA,KocerB, 2015.endobronchial intubation in thoracic surgery: which side should be preferred?,Asian Cardiovasc Thorac Ann 23 842 -5
InoueS,NishmineN,KitaguchiK,FuruyaH,Taniguchi S, 2004.Double lumen tube location predicts tube malposition and hypoxemia during one lung ventilation,Br J Anaesth 92 195 -201
AllaiumeN,CoddensJ,DeloofT., 1992.Relaibility of auscultation in positioning of souble lumen endobronchial tubes,Can j Anasth 39 687 -90
BalochRN,ZebE,HafeezS,ZaheerM., 2016.One lung anesthesia,Anestha pin Intensive care 20 S126 -35
SazakH,GoktasU,AlagozA,DemirbasCS,GuvenO,SavkiliogluE, 2012.Comparison of two different right sided double lumen tubes with different designs,Turk J Med Sci 42 1063 -9
De BellesM,AccardoR,Di MaioM,RossiGB,PaceMC, 2011.Is flexible bronchoscopy necessary to confirm the position of the double lumen tubers before thoracic surgery?,Eur J cardiothorac Surg 40 912 -6
KleinU,KarzaiW,BloosF,WohlfarthM,GottschallR,FritzH, 1998.Role of fiberoptic bronchoscopy in conjunction with the use of double lumen tubes for thoracic anesthesia: a prospective study,Anesthesiology 88 346 -50
HoştenT,TopcuS., 2011.The importance of bronchoscopic anatomy for anesthesiologists,Tuberk Toraks 59 416 -26
0

Citations

0

Downloads

82

Views