No Detail Found!

Change in Intraocular Pressure Following High Energy Nd: YAG Laser Posterior Capsulotomy.

Author(s)
Bilal Murtaza Armed Forces Institute of Ophthalmology (AFIO), National University of Medical Sciences (NUMS), Rawalpindi, Pakistan
Abdul Wahid Hussain General Headquarters Rawalpindi Pakistan, Pakistan
Abrar-Ul-Haq Military Hospital/National University of Medical Sciences (NUMS) Rawalpindi Pakistan
Asem Hameed Armed Forces Institute of Ophthalmology (AFIO), National University of Medical Sciences (NUMS), Rawalpindi, Pakistan
Abstract
Objective: To determine the mean rise in intra ocular pressure in patients undergoing high energy Nd: YAG laser posterior capsulotomy. Study Design: Descriptive case series study. Place and Duration of study: The study was carried out at CMH Kharian Cantonment in 9 months, from Feb 2014 to Nov 2014. Patients and Methods: Sixty eyes fulfilling the inclusion criteria were enrolled in the study by a non-probability purposive sampling. The base line IOP was measured with the help of Goldman Applanation Tonometer. The pupils were dilated by using 1% Tropicamide Eye drops, 1 drop repeated after every 10 minute. Proparacaine Hydrochloride Eye drops were used 1-2 times about 5 minutes before applying capsulotomy Lens (ABRAHAM CAPSULOTOMY YAG LENS) for topical Anesthesia.An opening of 3-4 mm was made in the posterior lens capsule, using Nd: YAG laser (VISULAS YAG III Carl Zeis Meditec AG Germany) ensuring use of least possible energy. Cumulative energy used was noted and entered in the study proforma. IOP was again assessed 4 hours after the procedure and entered in the study proforma. Mean rise in IOP was calculated. Results: Raised IOP was noted in 37 (61.66%) out of total 60 cases and IOP remained unchanged in 20 (33.33%) cases. Mean pre procedure IOP was 15.80 ± 2.979mm of Hg and mean post procedure IOP was 17.78 ± 3.954 mm of Hg and p-value using paired t-test was found to be 0.000 which was statistically significant indicating that use of high energy is associated with rise in IOP. Conclusion: There is significant rise in IOP associated with Nd: YAG laser posterior capsulotomy as evident from the statistical analysis. It is advisable to use minimum possible energy levels and all patients should undergo post procedure IOP check.
Publication Details
Page(s) 872-875
DOI DOI not available
Published Journal: Pakistan Armed Forces Medical Journal, Volume: 68, Issue: 4, Year: 2018

Request the full text from PASTIC

References
AwanMT,KhanMA,Al-KhairyS,MalikS., 2013.Improvement of visual acuity in diabetic and nondiabetic patients after Nd:YAG laser capsulotomy,Clin Ophthalmol 7 2011 -7
AwasthiN,GuoS,WagnerBJ, 2009.Posterior Capsular Opacification: A Problem Reduced but Not Yet Eradicated,Arch Ophthalmol 127 555 -62
YaziciAT,BozkurtE,KaraN., 2012.Long-term results of phacoemulsification combined with primary posterior curvilinear capsulorhexis in adults,Middle East Afr J Ophthalmol 19 115 -9
Morgan-WarrenPJ,SmithJA, 2013.Intraocular lens-edge design and material factors contributing to posterior-capsulotomy rates: comparing Hoya FY60aD, PY60aD, and Acry Sof SN60WF,Clin Ophthalmol 7 1661 -7
MuhammadL,JabeenM,WazirE,QadirA,SalimM,AhmadI., 2013.Efficacy of ND: YAG laser posterior capsulotomy in visual improvement of patients having posterior capsular spacification,Gomal J Med Sci 11 97 -100
SenneFM,TemporiniER,ArietaCE,PachecoKD, 2010.Perception of difficulties with vision-related activities of daily living among patients undergoing unilateral posterior capsulotomy,Clinics (Sao Paulo) 65 459 -468
GoreVS, 2012.The Study of Complications of ND: YAG Laser Capsulotomy,Int J Bioinformatics Res 4 265 -8
WaseemM,KhanHA, 2010.Association of raised intraocular pressure and its correlation to the energy used with raised versus normal intraocular pressure following Nd: YAG laser posterior capsulotomy in pseudophakes,J Coll Physicians Surg Pak 20 524 -27
BurqMA,TaquiAM, 2008.Frequency of retinal detachment and other complications after neodymium:Yag laser capsulotomy,J Pak Med Assoc 58 550 -2
SlomovicAR,ParrishII, 1985.Acute elevations of intraocular pressure following Nd:YAG laser posterior capsulotomy,Ophthalmology 92 973 -6
FlohrMJ,RobinAL,KelleyJS, 1985.Early complications following Q-switchedneodymium: YAG laser posterior capsulotomy,Ophthalmology 92 360 -3
ChannellMM,BeckmanH, 1984.Intraocular pressure changes after neodymium-YAG laser posterior capsulotomy,Arch Ophthalmol 102 1024 -6