No Detail Found!

Comparison of the Long-term and Short-term Fluctuations of Frequency-doubling Technology Perimetry Between Peripheral and Paracentral Zones of Visual Field.

Author(s)
Faisal Aziz Khan Department of Ophthalmology, Combined Military Hospital, Malir Cantt, Karachi, Pakistan
Mazhar Ishaq Department of Ophthalmology, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan
Amer Yaqub Department of Ophthalmology, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan
Abstract
Objective: To compare the long- and short-term fluctuations of frequency doubling technology perimetry between peripheral and paracentral zone and determine the relationship between threshold sensitivity and long- and short-term fluctuation within peripheral and paracentral zone of visual field. Study Design: Descriptive study. Place and Duration of Study: Eye Department, United Nations, Pakistan Field Hospital Level-3 Darfur, Sudan, from February to July 2015. Methodology: Normal eyes of 30 volunteers were recruited. Frequency doubling technology perimetry, program N-30, full threshold was employed. Each subject was tested at weekly intervals, once in the 1st, 3rd and 4th sessions and three times in the 2nd session. Visual field was divided into paracentral, superior, and inferior zones. Short-term and long-term fluctuation as well as threshold sensitivity were calculated for each patient as the mean fluctuation and mean sensitivity value. Mann-Whitney U-test was used to compare each zone in terms of their short- and long-term fluctuations and Spearman's rho correlation test for determining the relationship of threshold sensitivity with short- and long-term fluctuations. Results: Long-term fluctuation values differences were insignificant between superior and paracentral zones. Short-term fluctuation values were statistically insignificant between all three zones. Short-term fluctuation and threshold sensitivity in each zone did not correlate. Long-term fluctuation and threshold sensitivity had a very weak negative, statistically insignificant correlation in superior and paracentral zones. Conclusion: Frequency doubling perimetry exhibits uniform short- and long-term fluctuations in peripheral and paracentral zones of visual field in normal subjects. Threshold sensitivity and long- and short-term fluctuations are independent of each other in peripheral and paracentral zones of visual field.
Publication Details
Page(s) 140-144
DOI DOI not available
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 27, Issue: 3, Year: 2017

Request the full text from PASTIC

Keywords
Frequency doubling technique. Long-term fluctuation. Short-term fluctuation. Threshold sensitivity. Visual field tests/methods.
References
GardinerS,JohnsonC,DemirelS., 2012.The effect of test variability on the structure-function relationship in early glaucoma,Graefes Arch Clin Exp Ophthalmol 250 1851 -61
GardinerSK, 2014.Effect of a variability-adjusted algorithm on the efficiency of perimetric testing,Invest Ophthalmol Vis Sci 55 2983 -92
WallM,WoodwardKR,DoyleCK,ArtesPH, 2009.Repeatability of automated perimetry: A comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry,Invest Ophthalmol Vis Sci 50 974 -9
BlumenthalEZ,SamplePA,ZangwillL,LeeAC,KonoY,WeinrebRN, 2000.Comparison of long-term variability for standard and short-wavelength automated perimetry in stable glaucoma patients,Am J Ophthalmol 129 309 -13
BudenzDL,YanoffM,DukerJS, 2014.Visual field testing in glaucoma,Ophthalmology 1034 -
Pierre-FilhoPT,GomesPR,PierreET,PierreLM, 2010.Learning effect in visual field testing of healthy subjects using humphrey matrix frequency doubling technology perimetry,Eye 24 851 -6
SyedAN,QureshiNA,AkhtarF, 2011.Validity of frequency doubling technology to diagnose glaucoma,Al-Shifa J Ophthalmol 7 39 -47
ChonB,QiuM,LinSC, 2013.Myopia and glaucoma in the South Korean population,Invest Ophthalmol Vis Sci 54 6570 -7
MalhotraC, 2009.Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects,Oman J Ophthalmol 2 27 -32
SchmitiRB,CostaVP,FreitasTG,MagachoL,ArcieriES,Kara-Jose N, 2003.Learning effect and long- and short-term fluctuations in frequency doubling perimetry,Arq Bras Oftalmol 66 299 -304
ChauhanBC, 1999.Test-retest variability of frequencydoubling perimetry and conventional perimetry in glaucoma patients and normal subjects,Invest Ophthalmol Vis Sci 40 648 -56
CalixtoN,SantosRMO,CronembergerS., 2006.Visual field (Octupus 1-2-3) in normal subjects divided into homogenous age-groups,Arq Bras Oftalmol 69 637 -43
NayakBK,DharwadkarS., 2014.Interpretation of autoperimetry,J Clin Ophthalmol Res 2 31 -59
WaniJS,MirMS,NastiAR, 2005.- interpreting the data,JK Practitioner 12 219 -23
RameshSV,GeorgeR,SoniPM, 2007.Population norms for frequency doubling perimetry with uncorrected refractive error,Optom Vis Sci 84 496 -504
HoraniA,FrenkelS,YahalomC,FarberMD,TichoU,BlumentalEZ, 2002.The learning effect in visual field testing of healthy subjects using frequency doubling technology,J Glaucoma 11 511 -6
2015.Mechanisms of perimetric variability,pdf (accessed 31 July -
SpryPGD,JohnsonCA,McKendrikAM,TurpinA, 2001.Variability components of standard automated perimetry and frequencydoubling technology perimetry,Invest Ophthalmol Vis Sci 42 1404 -10
IesterM,CaprisP,PandolfoA,ZingirianM,TraversoCE, 2000.Learning effect, short-term fluctuation, and long-term fluctuation in frequency doubling technique,Am J Ophthalmol 130 160 -4
ArchibaldSK,HutchingsN,KilloranJA,IleyMD,FlanaganJG, 2015.org/magnitude-short-and-long-termfluctuation-normal-subjects-frequency-doubling-,technology (accessed 18 March -
0

Citations

0

Downloads

61

Views